Log in to see the plans as drawn NORTH
NOTES: REVISION
LICENSED PLUMBER TO VERIFY DOWNPIPE No. DATE DESCRIPTION ISS. BY
DECK
NUMBERS AND POSITIONS PRIOR TO
CONSTRUCTION OR ORDERING
PLATFORM IMMEDIATELY SURROUNDING
DWELLING TO FALL AWAY AT A SLOPE OF 1 IN 20.
SURFACE DRAINAGE TO DISCHARGE EVENLY
WITHOUT NUISANCE TO ADJOINING PROPERTIES
SITE TO BE SCRAPED CLEAN OF VEGETATION TO
BUILDING AREA
ALL LEVELS SHOWN ARE INDICATIVE ONLY AND
ARE TO BE CONFIRMED ON SITE. NO
RESPONSIBILITY TAKEN FOR ANY LEVELS SHOWN.
SURVEYORS PLANS TO TAKE PRECEDENCE OVER ENGINEERS TO SPECIFY
ANY LEVELS SHOWN ON THESE DOCUMENTS HOUSE POSTS FOR DOUBLE
LANDING BEARERS
ABOVE DECK ABOVE
PLUMBER TO DESIGN GROUNDWATER DRAINAGE ABOVE HOUSE
SYSTEM. ONE (1) YARD GULLY STANDARD ABOVE
NOTE: ENGINEERS DETAILS, DRAWINGS &
SPECIFICATIONS TO TAKE PRECEDENCE OVER
THESE DRAWINGS
HOUSE
BUILDER TO VERIFY ALL DIMENSIONS PRIOR TO
ORDERING ANY MATERIALS
SEAL ALL WET AREAS IN ACCORDANCE WITH AS
3740 & BCA REQUIREMENTS GRAVAL PAD ON GROUND
REFER TO ENGINEER'S
PLUMBER RESPONSIBLE TO LOCATE AND CONFIRM NEW DRAWINGS AND
SEWER HOUSE CONNECTION LOCATION DECK SPECIFICATIONS
ACCURATELY PRIOR TO COMMENCEMENT. ABOVE
PLUMBER IS TO VERIFY WITH SITE SUPERVISOR HOUSE ABOVE SSL 140200
PRIOR TO SETTING OUT FIXTURE DRAINAGE DECK
POINTS. NO AMENDMENTS OR SPECIAL FIXTURES
HAVE BEEN NOMINATED
REFER TO SPECIFICATION FOR ALL CONCRETE
SLAB FINISHES
WHERE SERVICES / PIPEWORK ARE LOCATED
.
UNDER DRIVEWAYS AND SLABS CONTRACTORS
. A
ARE TO ENSURE ADEQUATE COMPACTION TO
D
TRENCH BACKFILL ACHIEVED TO SUPPORT
R
CONCRETE
O
PROPOSED
REBATE GARAGE DOORS & SLIDING GLASS DOORS
U E F T I ON
I S S T F O R CO
20mm, AND SHOWER RECESSES 40mm IN
LOCATIONS SHOWN ACCORDING TO MANUF' SPEC.
OR BUILDERS DIRECTIONS N S TRUC
DEVELOPMENT SEWER CONNECTION DETAILS NO
AND INFORMATION WAS UNAVAILABLE AT THE
TIME OF WORKING DRAWINGS PREPARATION.
matt bradley designs
©MATT BRADLEY DESIGNS - ACN: 637 963 396 - ABN: 53 637 963 396
PLUMBER IS RESPONSIBLE TO DETERMINE
www.mattbradleydesigns.com.au - [email protected] - 0488 554 020
ALL DESIGN, CONSTRUCTION METHODS & MATERIALS TO BE IN ACCORDANCE WITH:
CONNECTION INFORMATION FROM - THE BUILDING CODE OF AUSTRALIA (BCA);
- THE QUEENSLAND DEVELOPER CODE (QDC);
- BUILDING REGULATIONS;
DEVELOPER AND TO COMPLY WITH ALL - CURRENT ISSUES OF AUSTRALIAN STANDARDS & MANUFACTURER'S
SPECIFICATIONS & INSTALLATION DETAILS FOR MATERIALS USED.
RELEVANT DETAILS AND REQUIREMENTS DIMENSIONS ARE SUBJECT TO SITE MEASUREMENT & VERIFICATION.
DO NOT SCALE OFF THIS DRAWING. PLANS COPYRIGHT MATT BRADLEY DESIGNS PTY LTD
PROJECT ADDRESS
411 BLACK PINCH ROAD,COOTHARABA
QLD 4565
SUBTERRANEAN TERMITES: DRAW ING TITLE
SUBTERRANEAN TERMITE PROTECTION TO BE IN NEW POST / SLAB SETOUT
ACCORDANCE WITH AS 3660. KORDON PHYSICAL
TERMITE BARRIER TO PERIMETER AND ALL SLAB
PLAN
PROTRUSIONS / PENETRATIONS. 80MM MIN CLIENT
MATT PAVELICH AND JUSTINE OXLEY
EXPOSED SLAB FACE TO PERIMETER TO ACT AS DRAW N
VISUAL DETECTION SYSTEM AGAINST TERMITE KD/EB
INFESTATION AS PER AS3660 AND ALL RELATED SCALE
1 : 100 @ A3
CODES. ANY OTHER SYSTEM USED MUST BE A DATE
CERTIFIED SYSTEM TO BCA REQUIREMENTS. 2022-05-09
PROJECT NO.
2022032
0 0.5 1 2 3 4 5 10m
WD-08
DRAW ING NO.
rev:
QBCC LICENCE: 15025395
SCALE = 1:100