Construction Drawings - 22 Key Court
2555 2680 4600 6370 2120 6870 1428 6254
N
GARAGE WALL IN
ACCORDANCE WITH QDCC
MEAN HEIGHT OF NOT
MORE THEN 3.5m
33.03
LINE OF LEVEL PARAPET
RH BELOW
2194
2124
2066
2688
FR DP FR
2686
LINE OF LEVEL
2569
BELOW RH RH
PARAPET
DP
FR OVERFLOW FR HT
DP DP FR RH W26 W27 DP RELIEF W28
FR FR W22 W23 W24 W25
HT A/C FR A/C TILED SEAT
W20 DP W21 DP
FG LINK FG
2537 FREE STANDING
CISTERN
TO DP
BATH FG 200mm FG
TILEBAND
LINE OF PELMET ENS FG
TERRACE
OVER
TILES
D10
00 ROBE
GLASS BALUSTRADE IN
4770
ACCORDANCE WITH ENS FG 6.1
2400 CEILING
0 50
TILES
0 BED 2
6.1
COUNCIL STANDARDS TILES
RL
TIMBER TILES
820 CSD
RL
PRIVACY 2400 CEILING TIMBER
2400 CEILING
SCREENS ROBE 2700 CEILING
GLASS BALUSTRADE IN
5320
BED 1 TILES SD ACCORDANCE WITH
9.35
ROBE TIMBER
LINK FG D9 TIMBER PRIVACY COUNCIL STANDARDS
00
2700 CEILING
TO DP
6.1
2700 CEILING LINE OF PELMET SCREENS
OVER 0
L .05
FG 200mm TILEBAND
R ROBE
6
TERRACE
50 LINE OF PELMET
OVER
CISTERN 820 D
R L
TILES
SITE REQUIREMENTS 18 17 16 15 14 13 12 11 10 9
1000 D
SD SD
LINE OF
PELMET PLANTER
SITE 642.42m² VOID OVER
50
DN LINE OF LEVEL
6.0
UPPER FLOOR BELOW
W19
RL
INTERNAL 130.06m² FR
EXERNAL TERRACE 28.83m² 0 HALLWAY 0
.10 .10 SD
4440
A W18 6 TIMBER 6 VOID
W9 FR
VOID
FR A
RL RL
LINE OF PELMET
OVER 2700 CEILING
20.12
NOTE:
VOID VOID
GLASS BALUSTRADES
-ALL TOILET DOORS TO HAVE 2424
W14
LIFT OFF HINGES LINE OF BEAM
OVER
-RL'S ARE ASSUMED
ONLY AND SHALL BE VERIFIED LINE OF PELMET 820 D
BY BUILDER PRIOR TO OVER
W13 ROBE
COMMENCEMENT OF SITE
7910
WORKS
FR
VOID
SD
W17 W15
KEY LINE OF ROOF LINE OF PELMET FIXED TIMBER
4480
OVER OVER SCREENS
HT W12 BED 3
HOSE TAP TIMBER
FG 2700 CEILING
FLOOR GULLY
0
.10
10.22
LINE OF PELMET TIMBER PERGOLA WITH
DP DOWN PIPE OVER ADJUSTABLE FINS WITH A 6
300mm BRASS SURROUND RL
D DOOR W11 820 CSD
LINE OF ROOF
OVER
W WINDOW LINE OF LEVEL
DP DP ENS BELOW
CISTERN
W16 FR
TILES
F FRIDGE FG
2010
700 x 350
COLUMN W10 2400 CEILING
RH RAIN HEAD
FG
S SPITTER
3800
3800
3800
FEATURE WINDOW
HOOD DP
MFR 1 deg KLIPLOK ROOFING PARAPET
DP
RH
2090
2090
FR CONCRETE FLAT ROOF
PD PLUMBING DUCT
FALL DIRECTION
31.91
G GAS POINT 6063 1700 6360 4500 650 3655 3020 6009
SD SMOKE DETECTOR
HW HOT WATER
DROPPED CEILING UPPER FLOOR PLAN
PAUL CLOUT DESIGN GENERAL NOTES: CLIENT NAME: Dorfman, Gershon
SITE ADDRESS: 22 Key Court, Noosa Heads
Suite 3, 44 MARY STREET, NOOSAVILLE Use written dimensions only. DO NOT scale drawings. Contractors to verify all
dimensions on site prior to commencing works. Site location is Category W41 or
PO BOX 152, NOOSAVILLE, QLD 4566.
to engineer's requirements. These drawings are to be read in conjunction with
DRAWING TITLE: UPPER FLOOR PLAN
BSA LICENCE: 1066417
engineer's design and details, the accompanying building specification and DRAWING DATE: 13/06/2024 SCALE: 1:100 on A3 DRAWING No:
PH: (07) 5440 5388
[email protected]
COPYRIGHT to PAUL CLOUT DESIGN PTY LTD
paulclout.com
schedule of finishes. If in doubt, please request clarification. DO NOT ASSUME. STAGE:
WORKING DRAWINGS 02.0
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take up to a minute.