                                                                                                         APPROVED PLAN                             SEACHANGE BUILDERS
                                                                                                                                      All designs, plans and drawings including all associated materials are subject


                                                                                                          132006.2554.01
                                                                                                                                              to copyright. Either written, design or specification is vested in
                                                                                                                                                         SEACHANGE BUILDERS design center.
                                                                                                                                     Any attempt or actural infringement by using, reproducing or copying the same,


                                                                                                         NOOSA COUNCIL
                                                                                                                                      wholly or in part without written consent will result in legal action being taken.




                                                                                                         10 AUGUST 2022              BUILDER N O T E :
                                                                                                                                     1. DO NOT SCALE DRAWINGS, USE WRITTEN DIMENSIONS ONLY.

                                                                                                                                     2. OWNER, BUILDER, SUBCONTRACTOR MUST VERIFY ALL DIMENSIONS
                                                                                                                                     AND LEVELS ON SITE PRIOR TO COMMENCING ANY WORKS OR
                                                                                                                                     ORDERING MATERIALS.

                                                                                                                                     3. BUILDER SHALL BE RESPONSIBLE FOR ENSURING THAT ALL BUILDING
                                                                                                                                     WORKS CONFORM TO THE BUILDING CODE OF AUSTRALIA, A.S CODES
                                                                                                                                     (CURRENT EDITIONS) BUILDING REGULATIONS, LOCAL BY-LAWS AND
                                                                                                                                     TOWN PLANNING REQUIREMENTS REPORT. ALL DISCREPANCIES TO BE
                                                                                                                                     REFERRED TO OWNERS OFFICE FOR CLARIFICATION.

                                                                                                                                     4. THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ARCHITECTURAL
                                                                                                                                     SPECIFICATION AND ENGINEERS SHOP DRAWINGS AND DETAILS.
                                                                  FIXED ALUMINUM WINDOW
                                                                  TINTED FINISH WEST FACING
                                                                                                                                     5. REGULAR INSPECTION OF THE PROPERTY BY A SUITABLY QUALIFIED
                                                                  450MM OR LARGER L-SHAPED HOOD
                                                                                                                                     PERSON AND THE ARRANGEMENT, SCHEDULING AND PAYMENT OF THE
                                                                  OVER WINDOWS FACING WEST
                                                                                                                                     INSPECTIONS WILL BE THE SOLE RESPONSIBILITY OF THE OWNER OR
                                                                                                                                     BUILDER.




                                                                                                                                      CONTRACT N O T E :
                                                                                                                                      1. THESE DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL
                                                                                                                                      CURRENT ENGINEERING DOCUMENTATION AND SPECIFICATIONS.

                                                                                                                                      2. BUILDERS SPECIFICATION AND NOMINATED FEES TAKE PRECEDENTS
                                                                  KNOTWOOD VERTICAL PANELS FIXED AT 150MM CENTERS                     OVER DRAWING NOTES.
                                                                  OR SIMILAR DETERMINED BY BUILDER ONSITE
                                                                  CONFIRM FIXING DETAILS WITH PROPOSED NEW GARDEN                     3. SIZES OF ITEMS INCLUDING WASHING MACHINE, DRYER, MICRO WAVE
                                                                                                                                      AND OVEN OR THE LIKE ARE TO BE CONFIRMED IN THE WRITTEN
                                                                                                                                      DOCUMENTATION PREPARED BY THE BUILDER.
                                                                  VERTICAL BURNT TIMBER PANELING
                                                                  OR SIMILAR AS PER BUILDERS SELECTION
                                                                                                                                     --------------------------------                  -------------------------
                                                                                                                                            OWNER                                             BUILDER
                                                                                                                                     --------------------------------                  -------------------------
                                                                                                                                            DATE                                              DATE


                                                                                                                                      EXISTING AREAS
                                                                                                                                      EXIST. BBQ & POOL LVL                            - 114.2m²
                                                                                                                                      EXIST. GROUND LVL                                - 323.8m²
                                                                                                                                      EXIST.UPPER LVL                                  - 283.6m²

                                                                                                                                      TOTAL AREA                                       -    721.6m²

                                                                                                                                      PROPOSED AREAS
                                                                                                                                      PRO. BBQ & POOL LVL    114.2m²
                                                                  HORIZONTAL TIMBER PANEL DOOR TO MATCH
                                                                                                                                      PROPOSED. GROUND LVL - 323.8m²
                                                                  FINISH TIMBER TEXTURE TO MATCH                                      PROPOSED.UPPER LVL   - 283.6m²
                                                                  KNOTWOOD VERTICAL BATTENS

                                                                                                                                      TOTAL AREA                                       -    721.6m²




                                       Proposed West Elevation                                                                         UTILITY CONTACTS

                                                                                                                                       1.         WATER:
                                                                                                                                       2.

                                                                                                                                       3.        GAS:


                                                                                                                                       4.         TELEPHONE:
                                                                                                                                                  TELSTRA
                                                                                               EXISTING SLIDING DOOR TO REMAIN
                                                                                                                                                  13 22 00

                                                                                                                                       5.        POWER:




                                                                                                                                                            N O T E:
                                                                                                                                               CONFIRMED ALL DIMENSIONS ON SITE.
                                                                                                                                          ALL CONTRACTORS ARE TO PROVIDE COMPLIANCE
                                                                                               EXISTING SLIDING DOOR TO REMAIN             CERTIFICATES FOR ELECTRICAL, PLUMBING AND
                                                                                                                                                  MECHANICAL ON COMPLETION.

                                                                                                                                                                        NORTH POINT
                                                                                                                                                                        LOCATION
                                                                                                                                                                        Latitude: 26.4569° S,
                                                                                                                                                                        Longitude: 153.0991° E
                                                                                                                                                                        MARCUS BEACH, QLD



                                                                                                                                      3         WINE CELLAR AND LIFT                                           16.1.22
                                                                                               PROPOSED SLIDING WINDOWS
                                                                                               REFER TO WINDOW SCHEDULE               2         CLIENT CHANGES                                                 10.12.21
                                                                                                                                      1         INITIAL CLIENT DRAFT                                           10.11.21




                                                                                                                                       Prop.Elevations

                                                                                               PROPOSED CONCRETE BENCHTOP
                                                                                               AS PER BUILDERS SPECIFICATIONS
                                                                                               DETAILS TO BE CONFIRMED




                                        Proposed East Elevation
                                                                                               PROPOSED ALUMINUM WINDOW
                                                                                               REFER TO WINDOW SCHEDULE



                                                                                                                                          DAYTONA AVE COOLUM BEACH
                                                                                                                                          Sunshine Coast Qld 4562
                                                                                                                                          Ph 07 3103 2996 Mob 0438231411
                                                                                                                                          BSA License 121 2275

                                                                                                                                          Scale:             1:100                    Dwg No:                  SH-14

                                                                                                                                          Date : FEB 2022                              Job No: 2021-73.14

Document Set ID: 22070347
Version: 1, Version Date: 12/08/2022

Used in these records

About this file

File size
4.1 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Approved Plans - 132006.2554.01.pdf · 4.1 MB (large file)