Original source · versioned page text
Compiled Plans - Approved - 51991.652.04
Plans and drawings: the text below has words only, no drawings.
¿ play your part - print on recycled paper
Details
LOT: 30 -
Plan : BUP 12150 NOOSA COUNCIL
Parish : Weyba
County : March APPROVED PLAN
LGA : Noosa Shire Council
Locality : Noosa Heads 51991.652.02 14 SEP 2018 PROPOSED
Zone : Vistitor Mixed Use ADDITIONS
HASTINGS
Housing Overlays :
STREET
EXISTING
Site Area : 2695m2 RESTAURANT
EXISTING UNITS
SITE NOTES
These schedules are to be read in conjunction with
architectural drawings, structural engineer and
hydraulic engineer drawings and any other external
consultants. Any discrepancy with these schedules or
other documentation is to be referred to the designer Location plan
for written direction prior to the commencement of 1:1000
works. All works to be carried out in accordance with
the engineers design and documentation.
All works to be in accordance with the Building Act
1975, Standard Building Regulation, Building Code of
Australia, Queensland Development Code, Local
government regulations and relevant Australian
Standards. The Builder is to clarify all dimensions on
site prior to the commencement of any works. The
author of the drawings takes no responsibility for
details as shown if changes are made during or prior to
construction without written notice or approval. Do not
scale off plans use figure dimensions only. The
maximum height of construction is to comply with the
local authority planning scheme (excluding relaxations
as per town planning approval). The author takes no 40.234m, 0° 0' 0.00"
44.770m, 0° 0' 0.00"
responsibility for cut/fill levels resulting from the
1.500m, 90° 0' 0.00"
PROPOSED
documented levels and contours. ADDITIONS
The Builder is to clarify all dimensions on site prior to
32.186m, 90° 0' 0.00"
the commencement of any works. The author of the
drawings takes no responsibility for details as shown if
changes are made during or prior to construction EXISTING
30.735m, 86° 46' 50.
HASTINGS
RESTAURANT
without written notice or approval. Do not scale off
STREET
plans use figure dimensions only.
The Builder is to comply with statutory and contractual
environmental protection requirements, including the
EXISTING UNITS
provision of sediment control barriers and controlled
gravel access to the site during construction, with best
practice methods used.
40"
Builder to locate all services before commencement of
construction.
House to be setout by a registered surveyor. Surveyor
to provide certificate at frame and completion stage for
confirmation of building setout and heights. 86.730m, 0° 0' 0.00"
Site plan
1:500
/Users/benthornton/Documents/Cadfiles/1308 - Sellman/Archicad/
22082018/1308.pln
sbt designs pty ltd t/a
Skale Building Design project Class 4 Residence lot no. 30 P3 Preliminary 22/8/18
project number
Mobile: 0412 025 657
31 Church Street Gympie Q 4570 for Gary Sellman plan no. BUP 12150 P1 Preliminary 12/12/17
1308
skale skale.com.au
building design
[email protected]
A.C.N. 123 976 296 QBCC: 1143 609 at
180/6 Hastings Street
Noosa Heads
drawn
scale (A3) 1:100, 1:500, 1:1000
BT
Rev Details Date
drawing number
1.0 P3 © Skale Building Design
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take up to a minute.
Full text of the other 9 pages
Page 2
¿ play your part - print on recycled paper 5m 4 3 2 1
-
NOOSA COUNCIL
APPROVED PLAN
51991.652.02 14 SEP 2018
A B New fabric awning over entry door. C D
Refer to Restaurant fit out details by others.
3 450 8 840 4 800
New concrete block wall to engineer design and
detail. Wall to achieve min. 90/90/90 FRL
Existing window/wall to be removed Existing door.
2 135
1 1
New suspended
concrete stairs
A A
4 990
3.1 3.1
Proposed Restaurant
(Detail by others)
2 135
2 2
1 500
Existing stairs unchanged.
3 3
New suspended
concrete landing.
Existing wall unchanged.
A B C D
Floor plan : Ground floor
1:100
/Users/benthornton/Documents/Cadfiles/1308 - Sellman/Archicad/
22082018/1308.pln
sbt designs pty ltd t/a
Skale Building Design project Class 4 Residence lot no. 30 P3 Preliminary 22/8/18
project number
Mobile: 0412 025 657
31 Church Street Gympie Q 4570 for Gary Sellman plan no. BUP 12150 P1 Preliminary 12/12/17
1308
skale skale.com.au
building design
[email protected]
A.C.N. 123 976 296 QBCC: 1143 609 at
180/6 Hastings Street
Noosa Heads
drawn
scale (A3)
BT
1:100 Rev Details Date
drawing number
1.1 P3 © Skale Building Design
Page 3
-
NOOSA COUNCIL
APPROVED PLAN
51991.652.02 14 SEP 2018
Page 4
¿ play your part - print on recycled paper 5m 4 3 2 1
-
NOOSA COUNCIL
APPROVED PLAN
51991.652.02 14 SEP 2018
A B New fabric awning over entry door. C D
Refer to Restaurant fit out details by others. 4.80 m
3 450 8 840 4 800
New concrete block wall to engineer design and
detail. Wall to achieve min. 90/90/90 FRL
Terrace to have new waterproofing and
selected external tiles installed to Existing window/wall to be removed
manufacturers specifications.
1 1
New suspended
concrete stairs
Bedroom
Tile
A A
4 990
3.1 Dining Lounge 3.1
Tile Tile
New suspended concrete floor to engineer Ens
Tile
design and detail. Floor to achieve min. self-closing –/60/30 fire
30/30/30 FRL door.
NEW CLASS 4 RESIDENCE
2 2
1 500
Existing stairs unchanged.
3 3
New timber framed balustrade wall to 1.0m above terrace floor level. Timber framed wall to be in accordance with
structural engineers design and detail. Provide 6.0mm Hardiflex™ sheeting installed in accordance with New suspended
manufacturers specifications. Cover battens over sheeting to be varied aluminium battens with Concept Click concrete landing.
screens by Woodform Architectural. (Batten pattern : 50 x 62, 25 x 42, 60 x 32, 25 x 42, 66 x 25 :
18mm spacings)
Provide rebated stainless steel planter box to top of wall.
Varied aluminium battens with Concept Click screens by Woodform Architectural. (Batten pattern : 50 x 62, 25 x 42,
60 x 32, 25 x 42, 66 x 25 :
18mm spacings) to form screen over balustrade to 1.5m above terrace floor level.
A B C D
Floor plan : First floor
1:100
/Users/benthornton/Documents/Cadfiles/1308 - Sellman/Archicad/
22082018/1308.pln
sbt designs pty ltd t/a
Skale Building Design project Class 4 Residence lot no. 30 P3 Preliminary 22/8/18
project number
Mobile: 0412 025 657
31 Church Street Gympie Q 4570 for Gary Sellman plan no. BUP 12150 P1 Preliminary 12/12/17
1308
skale skale.com.au
building design
[email protected]
A.C.N. 123 976 296 QBCC: 1143 609 at
180/6 Hastings Street
Noosa Heads
drawn
scale (A3)
BT
1:100 Rev Details Date
drawing number
1.2 P3 © Skale Building Design
Page 5
¿ play your part - print on recycled paper 5m 4 3 2 1
-
NOOSA COUNCIL
APPROVED PLAN
51991.652.02 14 SEP 2018
A B C D
3 450 8 840 4 800
New suspended concrete landing Existing concrete block wall to be extended
over shown dashed. in height to engineers design and detail.
Wall to achieve min. 90/90/90 FRL.
1 1
5° Pitch
5° Pitch
A A
4 990
3.1 3.1
1° Pitch
2° Pitch
2° Pitch
2 2
1 500
3 3
New insulated roof panels with Colorbond Ultra sheeting to Line of external wall under shown dashed.
manufacturers specifications. Wall to be min. 3.0m from fire source feature
New 316 Stainless steel box gutter to be
Existing concrete block wall to be extended in height to engineers fully supported with 19mm Marine grade
design and detail. Wall to achieve min. 90/90/90 FRL. formply. Gutter to have fall to rwo to
hydraulic engineers design and detail.
A B C D
Roof plan
1:100
/Users/benthornton/Documents/Cadfiles/1308 - Sellman/Archicad/
22082018/1308.pln
sbt designs pty ltd t/a
Skale Building Design project Class 4 Residence lot no. 30 P3 Preliminary 22/8/18
project number
Mobile: 0412 025 657
31 Church Street Gympie Q 4570 for Gary Sellman plan no. BUP 12150 P1 Preliminary 12/12/17
1308
skale skale.com.au
building design
[email protected]
A.C.N. 123 976 296 QBCC: 1143 609 at
180/6 Hastings Street
Noosa Heads
drawn
scale (A3)
BT
1:100 Rev Details Date
drawing number
1.3 P3 © Skale Building Design
Page 6
¿ play your part - print on recycled paper 5m 4 3 2 1
1 2 3 Existing concrete block wall to be extended -
in height to engineers design and detail.
150 x 40mm Custom folded 4 990 1 500 Wall to achieve min. 90/90/90 FRL. NOOSA COUNCIL
Colorbond Ultra barge flashing to
detail. APPROVED PLAN
51991.652.02 14 SEP 2018
STRATCO Edge guttters in
COLORBOND® Ultra steel to be
fixed in accordance with Folded Colorbond Ultra blade wing walls to detail.
manufacturers specifications.
8 410
Ceiling
New timber framed balustrade wall to 1.0m above terrace floor level. Timber
chs splayed posts to be in framed wall to be in accordance with structural engineers design and detail.
accordance with structural Provide 6.0mm Hardiflex™ sheeting installed in accordance with manufacturers
engineers design and detail. Posts specifications. Cover battens over sheeting to be varied aluminium battens with
to have hot dip galv. finish and Concept Click screens by Woodform Architectural. (Batten pattern : 50 x 62, 25 x
painted finish. 42, 60 x 32, 25 x 42, 66 x 25 :
18mm spacings)
5 700 Provide rebated stainless steel planter box to top of wall.
First floor Varied aluminium battens with Concept Click screens by Woodform Architectural.
Frameless clear glass panels to (Batten pattern : 50 x 62, 25 x 42, 60 x 32, 25 x 42, 66 x 25 :
provide balustrade. Balustrade 18mm spacings) to form screen over balustrade to 1.5m above terrace floor level.
panels to be fixed with rebated 316
stainless steel glazing channel.
Balustrade to be a min. 1000mm
high above finished floor level. New fabric awning over entry door.
Refer to Restaurant fit out details by others.
2 500
Ground floor
Northern Elevation
N/01 1:100
D C B A
New concrete block wall to engineer design and
detail. Wall to achieve min. 90/90/90 FRL
4 800 8 840 3 450
Folded Colorbond Ultra blade wing walls to detail.
Existing concrete block wall to be extended in
height to engineers design and detail. Wall to chs splayed posts to be in accordance with structural
achieve min. 90/90/90 FRL. engineers design and detail. Posts to have hot dip
galv. finish and painted finish.
New timber framed balustrade wall to 1.0m above terrace floor level. Timber framed
8 410 wall to be in accordance with structural engineers design and detail. Provide 6.0mm
Ceiling Hardiflex™ sheeting installed in accordance with manufacturers specifications. Cover
battens over sheeting to be varied aluminium battens with Concept Click screens by
Woodform Architectural. (Batten pattern : 50 x 62, 25 x 42, 60 x 32, 25 x 42, 66 x 25 :
New concrete block wall to engineer design and
18mm spacings)
detail. Wall to achieve min. 90/90/90 FRL
Provide rebated stainless steel planter box to top of wall.
Varied aluminium battens with Concept Click screens by Woodform Architectural.
(Batten pattern : 50 x 62, 25 x 42, 60 x 32, 25 x 42, 66 x 25 :
5 700 18mm spacings) to form screen over balustrade to 1.5m above terrace floor level.
First floor
New concrete block wall to engineer design and
detail. Wall to achieve min. 90/90/90 FRL STRATCO Edge guttters in COLORBOND® Ultra steel
to be fixed in accordance with manufacturers
specifications.
2 500
Ground floor
Eastern Elevation
E/01 1:100
/Users/benthornton/Documents/Cadfiles/1308 - Sellman/Archicad/
22082018/1308.pln
sbt designs pty ltd t/a
Skale Building Design project Class 4 Residence lot no. 30 P3 Preliminary 22/8/18
project number
Mobile: 0412 025 657
31 Church Street Gympie Q 4570 for Gary Sellman plan no. BUP 12150 P1 Preliminary 12/12/17
1308
skale skale.com.au
building design
[email protected]
A.C.N. 123 976 296 QBCC: 1143 609 at
180/6 Hastings Street
Noosa Heads
drawn
scale (A3)
BT
1:100 Rev Details Date
drawing number
2.1 P3 © Skale Building Design
Page 7
¿ play your part - print on recycled paper 5m 4 3 2 1
3 2 1 -
New window to be min. 3.0m from fire source feature
NOOSA COUNCIL
1 500 4 990
APPROVED PLAN
New concrete block wall to engineer
design and detail. Wall to achieve min. 51991.652.02 14 SEP 2018
90/90/90 FRL
Existing concrete block wall to be extended in height to
engineers design and detail. Wall to achieve min.
90/90/90 FRL.
8 410
Ceiling
New concrete block wall to engineer
design and detail. Wall to achieve min.
90/90/90 FRL
New suspended concrete roof to be provided over
existing walls.
5 700
First floor
New concrete block wall to engineer
design and detail. Wall to achieve min.
90/90/90 FRL
2 500
Ground floor
Southern Elevation
S/01 1:100 A B C D
New window to be min. 3.0m from fire source
feature
3 450 8 840 4 800
Folded Colorbond Ultra blade wing walls to detail.
Existing concrete block wall to be extended in
height to engineers design and detail. Wall to
STRATCO Edge guttters in COLORBOND® Ultra steel to be fixed in achieve min. 90/90/90 FRL.
accordance with manufacturers specifications.
8 410
Ceiling
chs splayed posts to be in accordance with structural engineers
design and detail. Posts to have hot dip galv. finish and painted finish.
5 700
First floor
2 500
Ground floor
Western Elevation
W01 1:100
/Users/benthornton/Documents/Cadfiles/1308 - Sellman/Archicad/
22082018/1308.pln
sbt designs pty ltd t/a
Skale Building Design project Class 4 Residence lot no. 30 P3 Preliminary 22/8/18
project number
Mobile: 0412 025 657
31 Church Street Gympie Q 4570 for Gary Sellman plan no. BUP 12150 P1 Preliminary 12/12/17
1308
skale skale.com.au
building design
[email protected]
A.C.N. 123 976 296 QBCC: 1143 609 at
180/6 Hastings Street
Noosa Heads
drawn
scale (A3)
BT
1:100 Rev Details Date
drawing number
2.2 P3 © Skale Building Design
Page 8
¿ play your part - print on recycled paper 5m 4 3 2 1
-
NOOSA COUNCIL
APPROVED PLAN
51991.652.02 14 SEP 2018
A B C D
New window to be min. 3.0m from fire source
feature
3 450 8 840 4 800
Folded Colorbond Ultra blade wing walls to
detail. Existing concrete block wall to be extended in
height to engineers design and detail. Wall to
STRATCO Edge guttters in COLORBOND® Ultra steel to be achieve min. 90/90/90 FRL.
fixed in accordance with manufacturers specifications.
8 410
Ceiling
chs splayed posts to be in accordance with structural
engineers design and detail. Posts to have hot dip galv. finish
and painted finish.
5 700
First floor
Existing wall and windows to be removed.
2 500
Ground floor
A B C D
New timber framed balustrade wall to 1.0m above terrace floor level. Timber framed
wall to be in accordance with structural engineers design and detail. Provide 6.0mm
Hardiflex™ sheeting installed in accordance with manufacturers specifications.
Cover battens over sheeting to be varied aluminium battens with Concept Click
screens by Woodform Architectural. (Batten pattern : 50 x 62, 25 x 42, 60 x 32, 25 x
42, 66 x 25 :
18mm spacings)
Provide rebated stainless steel planter box to top of wall.
Varied aluminium battens with Concept Click screens by Woodform Architectural.
(Batten pattern : 50 x 62, 25 x 42, 60 x 32, 25 x 42, 66 x 25 :
18mm spacings) to form screen over balustrade to 1.5m above terrace floor level.
Section A
A/3.1 1:100
/Users/benthornton/Documents/Cadfiles/1308 - Sellman/Archicad/
22082018/1308.pln
sbt designs pty ltd t/a
Skale Building Design project Class 4 Residence lot no. 30 P3 Preliminary 22/8/18
project number
Mobile: 0412 025 657
31 Church Street Gympie Q 4570 for Gary Sellman plan no. BUP 12150 P1 Preliminary 12/12/17
1308
skale skale.com.au
building design
[email protected]
A.C.N. 123 976 296 QBCC: 1143 609 at
180/6 Hastings Street
Noosa Heads
drawn
scale (A3)
BT
1:100 Rev Details Date
drawing number
3.1 P3 © Skale Building Design
Page 9
NOOSA COUNCIL
APPROVED PLAN
51991.652.04 20 JUNE 2023
20184339
Proposed Floor Plan (1)
Prepared by Crane Investments Noosa Pty Ltd
Revision A
13/03/2023
Page 10
NOOSA COUNCIL
APPROVED PLAN
51991.652.04 20 JUNE 2023
20184339
Proposed Floor Plan (2)
Prepared by Crane Investments Noosa Pty Ltd
Revision A
13/03/2023