Plans and drawings: the text below has words only, no drawings.

Log in to see the plans as drawn
¿ play your part - print on recycled paper                                                                                                                                                                                                                                         5m         4         3         2          1




                                                       3             2                                    1                                                                                                                                                                                       -

                                                                                                                   New window to be min. 3.0m from fire source feature
                                                                                                                                                                                                                                                                 NOOSA COUNCIL
                                                             1 500                     4 990
                                                                                                                                                                                                                                                                 APPROVED PLAN
     New concrete block wall to engineer
     design and detail. Wall to achieve min.                                                                                                                                                                                                                 51991.652.02 14 SEP 2018
     90/90/90 FRL

                                                                                                                   Existing concrete block wall to be extended in height to
                                                                                                                   engineers design and detail. Wall to achieve min.
                                                                                                                   90/90/90 FRL.
    8 410
    Ceiling
     New concrete block wall to engineer
     design and detail. Wall to achieve min.
     90/90/90 FRL
                                                                                                                   New suspended concrete roof to be provided over
                                                                                                                   existing walls.
    5 700
    First floor


     New concrete block wall to engineer
     design and detail. Wall to achieve min.
     90/90/90 FRL



    2 500
    Ground floor




                                         Southern Elevation
     S/01                                                        1:100                 A                      B                                                                C                                 D
                                                                                                                                                                                                                     New window to be min. 3.0m from fire source
                                                                                                                                                                                                                     feature
                                                                                                  3 450                                       8 840                                        4 800

     Folded Colorbond Ultra blade wing walls to detail.
                                                                                                                                                                                                                     Existing concrete block wall to be extended in
                                                                                                                                                                                                                     height to engineers design and detail. Wall to
     STRATCO Edge guttters in COLORBOND® Ultra steel to be fixed in                                                                                                                                                  achieve min. 90/90/90 FRL.
     accordance with manufacturers specifications.



                             8 410
                             Ceiling



     chs splayed posts to be in accordance with structural engineers
     design and detail. Posts to have hot dip galv. finish and painted finish.

                             5 700
                             First floor




                             2 500
                             Ground floor




                                           Western Elevation
     W01                                                         1:100
                                                                                                                                                                                                                                                                          /Users/benthornton/Documents/Cadfiles/1308 - Sellman/Archicad/
                                                                                                                                                                                                                                                                                                                     22082018/1308.pln
                         sbt designs pty ltd t/a
                         Skale Building Design                                   project       Class 4 Residence                             lot no.                                 30     P3     Preliminary                                                  22/8/18
                                                                                                                                                                                                                                                                            project number
                         Mobile: 0412 025 657
                         31 Church Street Gympie Q 4570                          for           Gary Sellman                                  plan no.                         BUP 12150     P1     Preliminary                                                 12/12/17
                                                                                                                                                                                                                                                                            1308
skale skale.com.au
  building design
                         [email protected]
                         A.C.N. 123 976 296 QBCC: 1143 609                       at
                                                                                               180/6 Hastings Street
                                                                                               Noosa Heads
                                                                                                                                             drawn
                                                                                                                                             scale         (A3)
                                                                                                                                                                                     BT
                                                                                                                                                                                   1:100   Rev     Details                                                        Date
                                                                                                                                                                                                                                                                            drawing number
                                                                                                                                                                                                                                                                            2.2                   P3             © Skale Building Design
Log in to download the original file

Compiled Plans - Approved - 51991.652.04.pdf · 4.2 MB (large file)