                                                                                                                                                        30



            Performance outcomes                              Acceptable outcomes                                         Response
storing in bulk.                                                                                          stored in the bushfire hazard area


Access and Evacuation Routes
PO6                                           AO6.1                                                   R6.1
Roads provide for easy and safe evacuation of The road layout provides for through-roads and
                                                                                                         The Waste Management Centre has internal
residents of premises and access by           avoids cul-de-sacs and dead-end roads.
                                                                                                          private roadways and a single access point
emergency services.
                                                                                                          onto a public roadway.
                                              OR
                                                                                                         However, the centre is separated from all
                                                                                                          areas of hazardous vegetation by sufficient
                                               AO6.2
                                                                                                          firebreak and fire management lines.
                                               The development has a perimeter road reserve
                                               with a minimum width of 20 metres and
                                               maximum gradient of 12.5%.

                                               OR

                                               AO6.3
                                               Cul-de-sacs or no-through roads are provided with
                                               fire trails or access easements, which are capable
                                               of being navigated by conventional vehicles and
                                               which link to through roads.

                                               AO6.4
                                               Safe access and egress is available at all times to
                                               all of the development for emergency vehicles
                                               and personnel.

                                               AO6.5
                                               Where an emergency access point is required, it

                                  RFA24-059 – Noosa Land Fill and Waste Management Facility – Bushfire Management Plan

Rob Friend & Associates Pty Ltd                                                10th of October 2024
Log in to download the original file

UPDATED DA - Attachment 6 - Bushfire Management Plan.pdf · 28.4 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.