NO. DESCRIPTION DATE
Door Schedule Window Schedule
No Description Level Qty Comments Mark Type Count Level Comments
D01 2100h x 1000w Alumn. Frame Glass Entry GROUND FLOOR FFL 2 Entry W01 2100h x 500w Louvre Window - Glass 152mm 2 GROUND FLOOR FFL Entry
Door W02 2100h x 700w Louvre Window - Anodised Alumn. Blade 2 GROUND FLOOR FFL Garage
D02 2100h x 2800w XO SGD w/ side lights louvres GROUND FLOOR FFL 2 152mm Blades - Bed 2 W03 500h x 1500w Sliding window OX - White Translucent 2 GROUND FLOOR FFL Bath / Laundry
D03 2100h x 5600w Garage Door Slimline GROUND FLOOR FFL 2 Panel Lift W04 2100h X 1000w Fixed Glass Window - 3 eq. panels 2 SECOND FLR FFL Entry Void - 3 eq.
D04 2100h x 1800w XO SGD GROUND FLOOR FFL 2 Garage bottom panel only, white translucent panels
D05 2100h x 2100w OX SGD GROUND FLOOR FFL 2 Bed 3 W05 1650h x 2600w Combination Awning Window 2 SECOND FLR FFL Bed 1
D06 2100h x 910w External Alumn. Frame (White GROUND FLOOR FFL 2 Bath / Laundry W06 500h x 700w Awning Window - White Translucent 2 SECOND FLR FFL Ensuite
Trans Glazing) W07 1200h x 500w Fixed / Awning Window - White Translucent 2 SECOND FLR FFL Ensuite
D07 2100h x 820w Internal Hinge Door GROUND FLOOR FFL 2 Garage W08 1200h x 1200w Sliding window OX 2 SECOND FLR FFL Kitchen
D08 2100h x 820w Internal Hinge Door GROUND FLOOR FFL 2 Bed 2 W09 1200h x 2100w Louvre / Awning / Louvre Window 2 SECOND FLR FFL Kitchen
D09 2100h x 820w Internal Hinge Door GROUND FLOOR FFL 2 Bed 3 PROJECT ADDRESS:
W10 1200h x 500w Awning Window - White Translucent 2 SECOND FLR FFL Powder
D10 2100h x 820w Internal Hinge Door GROUND FLOOR FFL 2 Bath W11 500 x 5000 Fixed Glass Window - White Translucent 2 SECOND FLR FFL Highlight 3 Corsair Cres,
D11 2100h x 3400w Sliding Robe Door GROUND FLOOR FFL 2 Bed 3 Robe W12 1300h x 700w Louvre Window - Anodised Alumn. Blade -Unit 2 only 1 SECOND FLR FFL Entry Void
D12 2100h x 3400w Sliding Robe Door GROUND FLOOR FFL 4 Bed 2 Robe
Sunrise Beach Qld
W13 2100h X 700w Fixed Glass Window - Unit 1 only 1 SECOND FLR FFL Entry Void
D13 2100h x 720w Internal Hinge door SECOND FLR FFL 2 Powder Room Grand total: 24 AUSTRALIA 4567
D14 2100h x 5358w 6 Panel SGD SECOND FLR FFL 2 Living
D15 2100h x 820w Internal Hinge Door SECOND FLR FFL 2 Bed 1
D16 2100h x 720w Internal Hinge door SECOND FLR FFL 2 Ensuite
CLIENT:
D17 2100h x 3000w Sliding Robe Door SECOND FLR FFL 2 Bed 1 Robe A. Warner /
D18 2100h x 1800w XO SGD SECOND FLR FFL 2 Rear Deck CLIENT APPROVAL OF WINDOW SCHEDULE K & C Hendrie
D19 28" x 84" GROUND FLOOR FFL 1 C/- PO Box 1234
Grand total: 39 SIGNATURE______________________DATE_________ Noosa Heads QLd 4567
DESIGNER:
Annette Warner Pty Ltd
CLIENT APPROVAL OF DOOR SCHEDULE
Building Design Consultants
PO Box 1234
SIGNATURE______________________DATE_________ Noosa Heads Qld 4567 Australia
ph: +61 7 5447 4893
DRAFTING:
NOTE:
Doors/windows with OXXO type notations:
O - fixed glass panel PO BOX 687,
X - operable glass panel NOOSA HEADS, QLD 4562
EMAIL: [email protected]
example - OX = left hand glass panel fixed, right hand QBCC: 1285397
glass panel slides as viewed from outside.
JOB NO.
ALL WINDOW HEAD HEIGHTS +2100 ABOVE FFL UNO KL15B13
NO FLYSCREENS TO DOORS AND WINDOWS
DRAWING TITLE
WINDOW & DOOR
SCHEDULE
DRAWING NUMBER
A100.2
NOTES Scale as shown @ A3
1. GENERALLY THE BUILDER SHALL COMPLY WITH THE REQUIREMENTS 3. FIGURE DIMENSIONS ONLY ARE TO BE USED, WITH NO DIRECT SCALING FROM 5. BUILDING METHODS ARE SUGGESTED ONLY. THE CONTRACTOR REMAINS
OF THE LOCAL AUTHORITIES AND ADHERE TO THE PROVISIONS OF THE THE DRAWINGS ALLOWED. RESPONSIBLE FOR ALL METHODS AND MATERIALS CONFORMING TO THE Rev Date : Rev No :
BUILDING CODE OF AUSTRALIA APPROPRIATE CODES AND STANDARDS
2. ALL DIMENSIONS SHOWN ON THE DRAWINGS ARE TO BE CHECKED
4. ALL LEVELS AND DIMENSIONS ARE TO BE CHECKED
6. ALL SCHEDULES ARE PROVIDED TO ASSIST WITH ESTIMATION ONLY.
CONSTRUCTION ISSUE 17/01/19 F
AND VERIFIED ON SITE BEFORE BUILDING WORK COMMENCES
ON SITE BEFORE WORK COMMENCES, ANY QUIERIES ARE TO BE DIRECTED IT IS THE RESPOSIBILITY OF THE BUILDER / CONTRACTOR
TO CONFIRM ALL QUANTITIES
TO THE DESIGN AUTHORITY - ANNETTE WARNER PTY LTD FOR CONSTRUCTION Drawn by : Checked by :
AXK AW
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
KL15B13_Corsair 19A17_FC.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.