Architectural Plans Received 11.8.2020 · MCU20/0087
Plans and drawings: the text below has words only, no drawings.
SHS SHS
90
90
INSITU SHOWER RECESSES CONSTRUCT 1760
AS PER BCA PART 3.8.1
NOTE: ENGINEER'S DETAILS & SPECIFICATIONS 90 7750 90
TO TAKE PRECEDENCE OVER THESE DRAWINGS.
SEAL WET AREAS IN ACCORDANCE
WITH AS 3740 & THE BCA RECESS FOR SLIDING DOOR
90
6620
6620
SUBTERRANEAN TERMITE PROTECTION METHOD TO BE IN ACCORDANCE 1760
WITH AS. 3660.1. TERMITE PROTECTION - KORDON TO ALL PENETRATIONS
AND KORDON TO PERIMETER OF BUILDING.
ANY OTHER SYSTEM USED MUST BE A CERTIFIED SYSTEM TO BCA REQUIREMENTS. 1940 6080 2880
190 2000 3800 190
90 1760
190
190
90
1000 4190 3690 3690
SHS
190
1840
1750
90 3600
700
0
2840
90
RECESS FOR GRATE TO SUIT
190
SHS
1000
90 3600
190
1400
1400
5090
1310
CONCRETE BLOCKWORK RETAINING WALLS
1210
FOR UPPER FLOOR LOWER FLOOR SLAB LAYOUT
4200
90
190
SHS
190
90
7670
4100
1400
1400
1310
2340
190
1210
1970
25mm RECESSED
WET AREA
90
5660
190
SHS
1400
1400
1310
1210
190
SUB FLOOR POST LAYOUT
BY STRUCTURAL ENGINEER
90
FULL HEIGHT POSTS
190 3940 (CONCRETE SLAB FLOOR
190
2580
2580
TO ENGINEERS
2580
2490
2490
DETAILS)
190
190 190
2160
4000 3500 6520
1970
3500
100
190 190 6150 4560
2780
7500
190
0
CONCRETE BLOCKWORK RETAINING WALLS
2447
SHS
810 190 844 SUB FLOOR POST LAYOUT
5180
4920
5010
BY STRUCTURAL ENGINEER
FULL HEIGHT POSTS
SUB FLOOR POST LAYOUT
SUB FLOOR POST LAYOUT BY STRUCTURAL ENGINEER 3650 CONCRETE BLOCKWORK RETAINING WALLS
BY STRUCTURAL ENGINEER FULL HEIGHT POSTS FOR UPPER FLOOR
FOR UPPER FLOOR
6370
SUB FLOOR POST LAYOUT
2400
FULL HEIGHT POSTS
BY STRUCTURAL ENGINEER
FULL HEIGHT POSTS
SHS SHS SHS
90
190 2447 7638 4015
1890
190 3480 90 4170 90 2790 90
SWIMMING POOL - ON UPPER LEVEL
(FINAL DESIGN BY POOL BUILDER)
10900
CONCRETE BLOCKWORK BASE TO TILED DECKS & POOL WALL
5280
14100
SLAB LAYOUT PLAN
SCALE 1:100
No. Description Date
Working Drawings Slab Layout Plan - Lower
29/07/2020 8:13:43 AM
Ric Stevens
199 Maximillian Road Project number 2440 REV 3 Revision
D E S I G N E RS : T I M & P H I L C H R I S T O P H E R & AS SOCIATES
email : [email protected] www.christopherdesigngroup.com.au BDAQ member
North Shore Date 29-7-20 Sheet 11
Drawn by TC
CHRISTOPHER DESIGN GROUP PTY LTD QBCC LICENSE No. 1307316
5/70 Bulcock Street CALOUNDRA Qld AUSTRALIA
ACN 604467450
OFFICE PH: 07 5491 4666
Proposed Residence Checked by TC Scale 1 : 100
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Architectural Plans Received 11.8.2020.pdfRelated documentApplication case desk ↗
About this file
- File size
- 4.2 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.