Council archive · source document
Architectural Plans Received 11.8.2020 · MCU20/0087
Plans and drawings: the text below has words only, no drawings.
TRUSSES TO TRUSS MANUFACTURERS SPECIFICATIONS
W COLORBOND CUSTOM ORB ULTRA ROOF SHEETING TO BE USED
W 6 FOR ROOF PITCHES OF 5 DEG OR GREATER.
8
5 DEG ROOF PITCH. COLORBOND CUSTOM ORB ROOF SHEETING
(TO SUIT ENVIRONMENT) FIXED AND FLASHED TO MANUF. SPECS ROOF INSULATION DETAILS:
W W
12A 12B 2000 900 BULK INSULATION : ANTICON UNDER ROOF SHEETING & BATTS TO CEILING
TO BE AS PER ENERGY ASSESSORS REQUIREMENTS
PINE TRUSSED ROOF FRAMING TO ALL AREAS EXCEPT WHERE
SHOWN AS RAKED OR RAFTERED CEILING.
SARKING TO BE PROVIDED TO ALL EXTERNAL WALLS.
INSULATION TO ALL WALLS AS PER ENERGY REQUIREMENTS
WALL CONSTRUCTIONS INCLUDE:
1. JAMES HARDIE LINEA 180 CLADDING WITH A PAINTED FINISH
ALL CONSTRUCTION TO BE CARRIED OUT IN ACCORDANCE
PLASTERBOARD LINING TO CEILING WITH THE BCA, A.S., INCL AS1684, QDC AND THE STANDARD
BUILDING REGULATIONS, ALONG WITH LOCAL COUNCIL REQUIRMENTS
AND ESTATE COVENANTS.
NO SUBSTITUTION OF PRODUCTS OR MATERIALS SPECIFIED
FINISHED HEIGHT
IS ALLOWED WITHOUT PRIOR PERMISSION FROM THE AUTHOR.
2700
NO RESPONSIBILTY WILL BE TAKEN BY CHRISTOPHER DESIGN GROUP FOR
ANY AMENDMENTS OR VARIATIONS MADE TO THESE PLANS
WITHOUT WRITTEN CONSENT.
ALL DIMENSIONS ARE TO BE VERIFIED BY THE BUILDER
PRIOR TO ORDERING ANY MATERIALS
DIMENSIONS ON THESE PLANS ARE TO BE USED OVER SCALE
SEAL WET AREAS IN ACCORD.
WITH AS 3740 & THE BCA. (NCC)
ALL CONSTRUCTION TO BCA REQUIREMENTS,
OPEN UNDER FLOOR S.B.R AND THE AUSTRALIAN STANDARDS.
SHS POST LAYOUT
TO ENGINEERS DRAWINGS BUILDER TO VERIFY ALL DIMENSIONS
PRIOR TO ORDERING ANY MATERIALS.
TIMBER FLOOR FRAMING NOTE: ALL PRIMARY BUILDING ELEMENTS TO BE
TERMITE RESISTANT.
CONCRETE BLOCKWORK RETAINING WALLS PLASTERBOARD LINING THROUGHOUT WALLS & CEILINGS INTERNALLY.
TO ENGINEERS DETAILS HARDIFLEX EAVES LINING OR SIMILAR FC USED IN SOFFIT AND EXTERNAL CEILING
UNLESS NOTED OTHER, ALL WITH A PAINTED FINISH TO MANUF. SPECS.
BUSHFIRE RATING - BAL 12.5
(PROVIDED BY FIRE RATING ASSESSOR)
ALL CONSTRUCTION IN THIS HOME MUST MEET
THE BAL 12.5 REQUIREMENTS AS SET OUT IN
Section
1 1 : 50 1-1 90 x 90mm SHS GALV SUPPORT POSTS
AS 3959-2009 AND ITS LATEST AMENDMENTS.
ALL TIMBER USED IN THIS HOME MUST MEET
TO ENGINEERS DETAILS
THIS CODE AND APPENDIX E, F, & H
No. Description Date
Working Drawings Section 1
29/07/2020 8:13:44 AM
Ric Stevens
199 Maximillian Road Project number 2440 REV 3 Revision
D E S I G N E RS : T I M & P H I L C H R I S T O P H E R & AS SOCIATES
email : [email protected] www.christopherdesigngroup.com.au BDAQ member
North Shore Date 29-7-20 Sheet 15
Drawn by TC
CHRISTOPHER DESIGN GROUP PTY LTD QBCC LICENSE No. 1307316
5/70 Bulcock Street CALOUNDRA Qld AUSTRALIA
ACN 604467450
OFFICE PH: 07 5491 4666
Proposed Residence Checked by TC Scale As indicated
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Architectural Plans Received 11.8.2020.pdfRelated documentApplication case desk ↗
About this file
- File size
- 4.2 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.