Original source · versioned page text
16216 Proposal Plans Part 3 of 3
Attached to the e-mail Proposal Plans 3 of 3 MCU17/0014.
X:\Archicology Projects\16416 Doonella Units\16416 SD model
\16416 SD model.pln
Issue 1 by NF on 24/06/16 for Client Review
Issue 2 by NF on 11/07/16 for Rev. Height
Issue 3 by NF on 24/08/16 for Re-Design Client Review
Issue 4 by NF on 01/09/16 for Rev.
Issue 5 by NF on 07/10/16 for Rev.
Issue 6 by NF on 18/10/16 for Rev.
Issue 7 by NF on 02/02/17 for Rev. Commercial / Communal
Site Boundary
Site Boundary
South Elevation 1
1
1:100
Site Boundary
Site Boundary
ELEVATION LEGEND
Fibre Cement + Battens
Render Finish
Colorbond Roof
FC Weatherboard
Matrix Wall System
Aluminium Battening
Vine Screen
Balustrade
Windows + Doors Powdercoated
South Elevation 2
2
1:100
ARCHICOLOGY
ph 5446 3113 fax 5446 3613
Po Box 579 Coolum Beach 4573
Site Boundary
Site Boundary
The builder shall check and verify all dimensions and
verify any errors and omissions to the architect. Do not
scale off drawings. Drawings shall not be issued for
construction purposes until issued by the Architect for
construction. In the first instance contact :
Mr Adrian Just on 0412 117772
Client Name
Project Name
Site Boundary
Doonella Units
30 & 32 Doonella St, Tewantin
QLD, 4566
Drawing Title:
Elevations
Scale: As shown Date: 2016
Status: SD Checked By: ACJ
West Elevation
3 Project No: Drawing No.:
1:100
16416 SD08
Plot Date: 3/02/2017
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original (16216 Proposal Plans Part 3 of 3.pdf)
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 2 pages
Page 2
X:\Archicology Projects\16416 Doonella Units\16416 SD model
\16416 SD model.pln
Issue 1 by NF on 24/06/16 for Client Review
Issue 2 by NF on 11/07/16 for Rev. Height
Issue 3 by NF on 24/08/16 for Re-Design Client Review
Issue 4 by NF on 01/09/16 for Rev.
Issue 5 by NF on 07/10/16 for Rev.
Issue 6 by NF on 18/10/16 for Rev. Dimensions
Issue 7 by NF on 02/02/17 for Rev. Commercial / Communal
3,093
2,643
8m above existing natural ground
C D
SD10 SD10 N
7.5° 7.5°
RL +13,850
A A Roof
SD09 SD09
Site Boundary
2,550
Site Boundary
Bed 1 Ens Hall Bed 1 Bed 1 Bed 1 Hall Ens Bed 1
RL +11,300
Level 2
350
6,262
8,962
7,205
8,962
Bed 2 Living Bed 2 Living Bed 2 Living Living Bed 2 Living Bed 2
2,550
B B
RL +8,400
SD09 SD09 Level 1
200
existing natural ground
Carpark
2,500
RL +5,700
Ground / Carpark
C D
SD10 SD10
Section Plan Section A
1 2
1:500 1:100
1,953 19,190 1,800 16,750 21,148
2,553 17,990 3,000 19,000 14,800 3,498
Site Boundary
8m above existing natural ground
RL +13,850
Roof
12.5° 12.5°
RL +11,300
Level 2
3,000
Site Boundary
2,800
6,092
5,023
2,800
7,610
6,275
Commercial Commercial Commercial
5,483
6,079
RL +8,400
Level 1
existing natural ground Carpark
ARCHICOLOGY
ph 5446 3113 fax 5446 3613
RL +5,700
Po Box 579 Coolum Beach 4573
Ground / Carpark
The builder shall check and verify all dimensions and
verify any errors and omissions to the architect. Do not
scale off drawings. Drawings shall not be issued for
construction purposes until issued by the Architect for
construction. In the first instance contact :
Section B
3 Mr Adrian Just on 0412 117772
1:100
Client Name
Project Name
Doonella Units
30 & 32 Doonella St, Tewantin
QLD, 4566
Drawing Title:
Sections
Scale: As shown Date: 2016
Status: SD Checked By: ACJ
Project No: Drawing No.:
16416 SD09
Plot Date: 3/02/2017
Page 3
X:\Archicology Projects\16416 Doonella Units\16416 SD model
\16416 SD model.pln
Issue 1 by NF on 24/06/16 for Client Review
Issue 2 by NF on 11/07/16 for Rev. Height
Issue 3 by NF on 24/08/16 for Re-Design Client Review
Issue 4 by NF on 01/09/16 for Rev.
Issue 5 by NF on 07/10/16 for Rev.
Issue 6 by NF on 18/10/16 for Rev. Dimensions
Issue 7 by NF on 02/02/17 for Rev. Commercial / Communal
C D
Site Boundary
SD10 SD10 N
20°
5,506
nd
8m above existing natural grou 2,506 3,000
A A RL +13,850
SD09 SD09
Roof
Site Boundary
2,550
6,000 Fire Stairs Bed 2 Bed 1 Balcony
2°
RL +11,300
Level 2
350
10,350
7,573
8,467
6,342
Lift Fire Stairs Ens Bath Bed 2 Balcony
2,550
B B
SD09 SD09 RL +8,400
Level 1
200
existing natural ground Carpark Fire Stairs
2,500
RL +5,700
C D
SD10 SD10 Ground / Carpark
Section Plan Section C
3 1
1:500 1:100
Site Boundary
6,000 5,058
2,050 3,008
7.5° 7.5°
nd
8m above existing natural grou
RL +13,850
Roof
Site Boundary
2,550
Entry Dining Kitchen Balcony
6,000
RL +11,300
Level 2
5,129
350
ARCHICOLOGY
7,784
9,633
7,000
2,800
Commercial Communal Space Entry Kitchen Dining Living Balcony ph 5446 3113 fax 5446 3613
2,550
Po Box 579 Coolum Beach 4573
RL +8,400
Level 1 The builder shall check and verify all dimensions and
200
verify any errors and omissions to the architect. Do not
scale off drawings. Drawings shall not be issued for
Carpark
2,500
construction purposes until issued by the Architect for
l ground
existing natura construction. In the first instance contact :
RL +5,700 Mr Adrian Just on 0412 117772
Ground / Carpark
Client Name
Project Name
Section D Doonella Units
2
1:100 30 & 32 Doonella St, Tewantin
QLD, 4566
Drawing Title:
Sections
Scale: As shown Date: 2016
Status: SD Checked By: ACJ
Project No: Drawing No.:
16416 SD10
Plot Date: 3/02/2017