Original source · versioned page text
RAP15/0008 - Attachment 1
r.p.d.
lot 01 DP 1198266
CNR OVERTON WAY AND MAIN STREET
KIN KIN
50.0
site area 1688.5 SQ.M 54.0 53.0 52.0
site cover 205 SQ.M 11.9% 51.0
55.0 50.00
72857 102°55'50"
2.010
56.0
4.427
FILL SEPTIC
TRANSPIRATON
PIT
901
OVERTON WAY
19.
20513
196°42'
9.0 X 6.0 SHED
PROPOSED RESIDENCE
FFL 53.700
CUT PAD LEVEL 53.500
PROPOSED DRIVEWAY
3
348°
0
2746 5'40"
32.767
6.039
3.300
23715
53599
EXISTING TREE
284°24'15"
EXISTING TREE EXISTING TREE EXISTING TREE
EXISTING TREE
CROSS OVER
SITE PLAN
SCALE 1 : 200 MAIN STREET
THIS DRAWING REMAINS THE PROPERTY OF IPHORM Scale 1 : 200 C / O AXIS CERTIFICATION
PRINCIPAL DESIGNER LUKE STEPHENS Sheet No.
BUILDING DESIGNS AND LUKE STEPHENS Drawn by LCS
QBSA LIC NO 1105547 AND IS PROVIDED FOR THE USE AS DESCRIBED ABOVE
LOT 1 OVERTON WAY KIN KIN
E : [email protected] AND MAY NOT BE USED OR REPRODUCED IN WHOLE OR Date MAY 2015
SITE LAYOUT WD02
M : 0432 597 538 ANY PART WITHOUT WRITTEN PERMISSION Issue Job number .
A : 220 Darlington Drive Banora Point A
ATTACHMENT 1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 4 pages
Page 2
SPECIFICATION NOTES 18000
roof access panel
TIE-DOWN AND BRACING AS PER STRUCTURAL
ENGINEERS' DETAILS. S indicates smoke detector
WALL FRAMING 78 5896 78 5896 78 5896 78
WALL FRAMING TO FRAMING notes :
MANUFACTUERES SPECIFICATIONS 78 4100 78 1. lift-off doors to be fitted to wc
INTERNAL LININGS 2. smoke alarms to comply with BCA class 1&10
ALL INTERNAL WALL AND CEILING LININGS 1 part 3.7.2 and with AS. 3786.
WD08
GENERALLY TO BE PLASTERBOARD.
3. bathroom windows to be glazed obscure
VILLABOARD TO WET AREAS TO BE TILED.
78
78
STORE
3883
3883
2040
820
78
78
8000
8000
2040
CARPORT LOUNGE 820
3883
3883
ASW
BED 04
0.9 / 1.8
2040
820
78
78
1.8 / 0.9 1.5 / 1.8
DH ASW
1799
1122
78 5896 78 5896 78 5896 78
GROUND FLOOR AREA
GARAGE 47.7 SQ.M
GROUND FLOOR 96.3 SQ.M
TOTAL AREA
1
GROUND FLOOR PLAN WD08 144 SQ.M
SCALE 1 : 100
THIS DRAWING REMAINS THE PROPERTY OF IPHORM Scale 1 : 100 C / O AXIS CERTIFICATION
PRINCIPAL DESIGNER LUKE STEPHENS Sheet No.
BUILDING DESIGNS AND LUKE STEPHENS Drawn by LCS
QBSA LIC NO 1105547 AND IS PROVIDED FOR THE USE AS DESCRIBED ABOVE
LOT 1 OVERTON WAY KIN KIN
E : [email protected] AND MAY NOT BE USED OR REPRODUCED IN WHOLE OR Date MAY 2015
GROUND FLOOR PLAN WD04
M : 0432 597 538 ANY PART WITHOUT WRITTEN PERMISSION Issue Job number .
A : 220 Darlington Drive Banora Point A
ATTACHMENT 1
Page 3
18000
78 2800 78 7154 78 1600 78 1000 78 1900 78 3000 78
78 1900 78 4000 78
1
WD08
78
78
3000
3340
KITCHEN BED 03
DINING
78
8000
8000
160 600
2188
WIR
78
MASTER BED LOUNGE BED 02
3744
2500
ENS
78
VERANDAH
3000
78 2300 78 3600 78 7560 78 650 3500 78
roof access panel
18000
S indicates smoke detector
UP
UP notes :
1. lift-off doors to be fitted to wc
2. smoke alarms to comply with BCA class 1&10
1 part 3.7.2 and with AS. 3786.
WD08
3. bathroom windows to be glazed obscure
UPPER FLOOR PLAN
SCALE 1 : 100
THIS DRAWING REMAINS THE PROPERTY OF IPHORM Scale 1 : 100 C / O AXIS CERTIFICATION
PRINCIPAL DESIGNER LUKE STEPHENS Sheet No.
BUILDING DESIGNS AND LUKE STEPHENS Drawn by LCS
QBSA LIC NO 1105547 AND IS PROVIDED FOR THE USE AS DESCRIBED ABOVE
LOT 1 OVERTON WAY KIN KIN
E : [email protected] AND MAY NOT BE USED OR REPRODUCED IN WHOLE OR Date MAY 2015
UPPER FLOOR PLAN WD05
M : 0432 597 538 ANY PART WITHOUT WRITTEN PERMISSION Issue Job number .
A : 220 Darlington Drive Banora Point A
ATTACHMENT 1
Page 4
600 deep window hoods
FCL
2420
2420
FFL
FCL
2700
2700
FFL
EAST ELEVATION 600 deep window hoods
SCALE 1 : 100
HARDIEFLEX SHEET CLADDING WITH BATTEN
600 deep window hoods COVER STRIPS WITH APPLIED PAINT FINISH.
INSTALLED TO MANUFACTURERS
to all windows with no eaves SPECIFICATIONS.
SELECT COLORBOND C.G.I. ROOF SHEETING
PC ALUM SLIDING DOORS &
WINDOWS TO AS 2047/48
FCL
2420
FFL
FCL
2700
FFL
NORTH ELEVATION
SCALE 1 : 100
THIS DRAWING REMAINS THE PROPERTY OF IPHORM Scale 1 : 100 C / O AXIS CERTIFICATION
PRINCIPAL DESIGNER LUKE STEPHENS Sheet No.
BUILDING DESIGNS AND LUKE STEPHENS Drawn by LCS
QBSA LIC NO 1105547 AND IS PROVIDED FOR THE USE AS DESCRIBED ABOVE
LOT 1 OVERTON WAY KIN KIN
E : [email protected] AND MAY NOT BE USED OR REPRODUCED IN WHOLE OR Date MAY 2015
ELEVATIONS WD06
M : 0432 597 538 ANY PART WITHOUT WRITTEN PERMISSION Issue Job number .
A : 220 Darlington Drive Banora Point A
ATTACHMENT 1
Page 5
FCL
2420
2420
FFL
FCL
2700
FFL
WEST ELEVATION
SCALE 1 : 100
FCL
2420
2100
JOINERY HEIGHT
FFL
FCL
2700
FFL
SOUTH ELEVATION
SCALE 1 : 100
THIS DRAWING REMAINS THE PROPERTY OF IPHORM Scale 1 : 100 C / O AXIS CERTIFICATION
PRINCIPAL DESIGNER LUKE STEPHENS Sheet No.
BUILDING DESIGNS AND LUKE STEPHENS Drawn by LCS
QBSA LIC NO 1105547 AND IS PROVIDED FOR THE USE AS DESCRIBED ABOVE
LOT 1 OVERTON WAY KIN KIN
E : [email protected] AND MAY NOT BE USED OR REPRODUCED IN WHOLE OR Date MAY 2015
ELEVATIONS WD07
M : 0432 597 538 ANY PART WITHOUT WRITTEN PERMISSION Issue Job number .
A : 220 Darlington Drive Banora Point A
ATTACHMENT 1