Tuesday, 15 June 2021

Our Ref: 21038
Council Ref: MCU21/0031


        NOOSA COUNCIL
        PO BOX 141
        TEWANTIN QLD 4565

        ATTENTION: PATRICK MURPHY


Dear Patrick

INFORMATION RESPONSE
497 BLACK MOUNTAIN ROAD, BLACK MOUNTAIN
LOT 7 RP 838780

Further to your information request for the abovementioned development application we now
respond to all of the information requested.
1.    Amended plans and supporting written response demonstrating that the proposal complies, or
      proposed variations are suitably justified, with the relevant assessment benchmarks within the
      Low Density Housing Code.

Response
Please refer to the amended plans and assessment of the Low Density Housing Code at Attachments
1 and 2 respectively.


2.    Amended plans to accurately demonstrate the slope on which the proposed building is to be
      sited and an assessment of the proposal against AO15 of the Rural Zone Code.

Response
Please refer to the amended plans at Attachment 1. The proposed accessway is not on land with
a slope greater than 25%.

3.    Demonstrate compliance with the requirements of the Regional Infrastructure Overlay Code.

Response
An assessment against Table 8.2.9.4 of the Regional Infrastructure Overlay Code is provided at
Attachment 2. The electricity transmission line corridor is 119m wide. The proposed secondary
dwelling is setback 27.9m from the easement and greater than 58m (approx.) from the overhead lines.
The proposed siting of the secondary dwelling clearly provides adequate separation and does not
compromise the operation of the electricity infrastructure.


4.    Provide detailed plans, prepared by a RPEQ, clearly indicating the location and alignment of the
      proposed access to the proposed secondary dwelling, including details on, but not limited to:

      4.1.     dimensions, materials proposed to be used, gradients, cross falls, longitudinal section,
               cross-sections, extent of batters, etc.
Log in to download the original file

Information Response.pdf · 9.7 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

Full text of the other 23 pages

Page 2

Response
The attached long-section (refer Attachment 1) has been derived from levels from Council’s mapping
and shows that the new driveway has reasonable longitudinal grades ranging from 7% to 13.6% and
will therefore function satisfactorily. Cross-sections can only be provided properly when accurate
levels are obtained from a site survey. Due to relatively minor nature of the driveway works it is not
unreasonable to assume that RPEQ designed driveway and erosion and sediment control will meet all
Council’s Engineering design standards. At this stage of the application process, it is recommended
that conditions of approval requiring RPEQ driveway design and erosion and sediment control
measures could reasonably be applied.

5.    Provide a detailed Erosion and Sediment Control Management Plan, prepared by a
      CPESC or RPEQ, which includes information on, but not limited to:

      5.1. Layout of proposed controls during construction;
      5.2. How “dirty” water will be managed;
      5.3. How “clean” water will be diverted from the destabilised area;
      5.4. How the works will be stabilised immediately after being completed;
      5.5. How areas that are not part of the final cut/fill pad but will be disturbed as part of the works
          (access tracks, manoeuvring areas, etc.) will be stabilised in the short and long term;
      5.6. Maintenance regime of the proposed controls;
      5.7. Where the topsoil will be stockpiled and how it will be stabilised.

Response
As per response to 4. above. Due to relatively minor nature of the driveway works it is not
unreasonable to assume that RPEQ designed driveway and erosion and sediment control will meet all
Council’s Engineering design standards. At this stage of the application process, it is recommended
that conditions of approval requiring RPEQ driveway design and erosion and sediment control
measures could reasonably be applied.


6.    Provide CPESC or RPEQ certification that all proposed E&S controls have been sized in
      accordance with relevant standards and legislation, and suitable contingency measures will be
      available onsite, or able to be deployed to site prior to being required.

Response
As per responses 4 and 5 above. It is appropriate for Council to condition the approval to require
RPEQ certification be submitted prior to a Development Permit for Buildings Works being issued.


Part 3: Information Request has now concluded and the application is now in Part 5: Decision.

Should you have any questions with respect to the above, please do not hesitate to contact me direct.

Yours faithfully
PROJECT URBAN



Amanda Madden
Senior Planner
Email: [email protected]

Page 3

ATTACHMENT 1
 Amended Plans


[OCR of page images]
ATTACHMENT 1

 

Amended Plans

Page 4

       NORTH




  CONTOUR INTERVAL: 1.0m
  CONTOUR INFORMATION DERIVED FROM 'NOOSA
  COUNCIL ENTERPRISE MAPPING SYSTEM' WEBSITE
  MODULE:              PROPERTY RECREATION UTILITIES
  LAYER:               CONTOURS (1m)
  DATE DOWNLOADED: 08/04/2021


  AERIAL PHOTOGRAPH SOURCED
  FROM NEARMAP 'VERTICAL' CAPTURE
  DATED: 27/04/2020


  PROPOSED BUILDING ENVELOPE LINEWORK
  DERIVED FROM LINEA DESIGN & DRAFTING PLAN:
  'PROPOSED SECONDARY DWELLING'
  JOB NO.:   2020788
  SHEET NO.: 1
  DATED:     26/10/2020


  EASEMENT A ON RP135782 LINEWORK
  DERIVED FROM QUEENSLAND SPATIAL
  CATALOGUE (QSPATIAL) DCDB.
  DATED: 09/02/2021

                                                                                                                                                LEGEND:
  THIS IS A SITE PLAN ONLY AND IS SUBJECT TO
  LOCAL AUTHORITY APPROVAL AND ENGINEERING
                                                                                                                                                          PROPOSED BUILDING ENVELOPE
  CONSTRAINTS.
  DISTANCES ARE APPROXIMATE ONLY AND
  SUBJECT TO FINAL SURVEY.                                                                                                                                EXISTING BUILDING ENVELOPE


 0      10      20        30   40   50             75        100 Metres                                                                                   EXISTING DRIVEWAY

  Original Scale 1:1000                                                                                                                                   CONTOUR



DAVID WRIGHT HOUSE REMOVERS & DEMOLITION                                            REVISION
                                                                                        -
                                                                                                DATE
                                                                                               080421
                                                                                                                DESCRIPTION
                                                                                                               FOR APPROVAL
                                                                                                                                        DRAWN CHECKED
                                                                                                                                          TT    AM
DWG NO. 21038.01.D             DATE 070521     SCALE 1:1000 @ A3     SHEET 1 OF 4      A       150421   UPD PROPOSED BLDG ENV & D'WAY     TT    AM
                                                                                       B       220421   UPDATED PROPOSED DRIVEWAY         TT    AM
                                                                                       C       300421   UPD ACCESS & TURNING AREA ADD     TT    AM

SITE PLAN - PROPOSED SECONDARY DWELLING                                                D       040521    PRO DRIVEWAY SECTIONS ADDED      TT    AM
                                                                                                                                                        Sunshine Coast
                                                                                                                                                        tel. 07 5443 2844
                                                                                                                                                                                [email protected]
OF LOT 7 ON RP838780                                                                                                                                                             www.ProjectUrban.com.au
                                                                                                                                                                                     Project Urban Pty Ltd
497 BLACK MOUNTAIN ROAD, BLACK MOUNTAIN QLD                                                                                                                                   ACN 608 895 923 ABN 97 608 895 923

Page 5

       NORTH




  LANDSLIDE HAZARD AREAS (HIGH & MODERATE)
  INFORMATION DERIVED FROM 'NOOSA COUNCIL
  ENTERPRISE MAPPING SYSTEM' WEBSITE
  MODULE:        NOOSA PLAN 2020
  LAYERS:        HIGH HAZARD AREA
             &   MODERATE HAZARD AREA
  DATE DOWNLOADED: 08/04/2021


  CONTOUR INTERVAL: 1.0m
  CONTOUR INFORMATION DERIVED FROM 'NOOSA
  COUNCIL ENTERPRISE MAPPING SYSTEM' WEBSITE
  MODULE:              PROPERTY RECREATION UTILITIES
  LAYER:               CONTOURS (1m)
  DATE DOWNLOADED: 08/04/2021


  AERIAL PHOTOGRAPH SOURCED
  FROM NEARMAP 'VERTICAL' CAPTURE
  DATED: 27/04/2020


  PROPOSED BUILDING ENVELOPE LINEWORK
  DERIVED FROM LINEA DESIGN & DRAFTING PLAN:
  'PROPOSED SECONDARY DWELLING'
  JOB NO.:   2020788
  SHEET NO.: 1
  DATED:     26/10/2020


  EASEMENT A ON RP135782 LINEWORK                                                                                                               LEGEND:
  DERIVED FROM QUEENSLAND SPATIAL
  CATALOGUE (QSPATIAL) DCDB.                                                                                                                              PROPOSED BUILDING ENVELOPE
  DATED: 09/02/2021

                                                                                                                                                          EXISTING BUILDING ENVELOPE
  THIS IS A SITE PLAN ONLY AND IS SUBJECT TO
  LOCAL AUTHORITY APPROVAL AND ENGINEERING
                                                                                                                                                          EXISTING DRIVEWAY
  CONSTRAINTS.
  DISTANCES ARE APPROXIMATE ONLY AND
  SUBJECT TO FINAL SURVEY.                                                                                                                                HIGH LANDSLIDE HAZARD AREA


 0      10      20        30   40   50             75        100 Metres                                                                                   MODERATE LANDSLIDE HAZARD AREA

  Original Scale 1:1000                                                                                                                                   CONTOUR



DAVID WRIGHT HOUSE REMOVERS & DEMOLITION                                            REVISION
                                                                                        -
                                                                                                DATE
                                                                                               080421
                                                                                                                DESCRIPTION
                                                                                                               FOR APPROVAL
                                                                                                                                        DRAWN CHECKED
                                                                                                                                          TT    AM
DWG NO. 21038.01.D             DATE 070521     SCALE 1:1000 @ A3     SHEET 3 OF 4      A       150421   UPD PROPOSED BLDG ENV & D'WAY     TT    AM
                                                                                       B       220421   UPDATED PROPOSED DRIVEWAY         TT    AM
                                                                                       C       300421   UPD ACCESS & TURNING AREA ADD     TT    AM

SITE PLAN - LANDSLIDE HAZARD AREA                                                      D       040521    PRO DRIVEWAY SECTIONS ADDED      TT    AM
                                                                                                                                                        Sunshine Coast
                                                                                                                                                        tel. 07 5443 2844
                                                                                                                                                                                [email protected]
OF LOT 7 ON RP838780                                                                                                                                                             www.ProjectUrban.com.au
                                                                                                                                                                                     Project Urban Pty Ltd
497 BLACK MOUNTAIN ROAD, BLACK MOUNTAIN QLD                                                                                                                                   ACN 608 895 923 ABN 97 608 895 923

Page 6

       NORTH




 PROPOSED DRIVEWAY
     PLAN VIEW
            SCALE 1:500




                                                                                                                                                    PROPOSED DRIVEWAY
                                                                                                                                                 LONGITUDINAL SECTION A-A1
                                                                                                                                                                   SCALE 1:250




  AERIAL PHOTOGRAPH SOURCED
  FROM NEARMAP 'VERTICAL' CAPTURE
  DATED: 27/04/2020                                   LEGEND:
                                                               PROPOSED BUILDING ENVELOPE
  PROPOSED BUILDING ENVELOPE LINEWORK
  DERIVED FROM LINEA DESIGN & DRAFTING PLAN:
  'PROPOSED SECONDARY DWELLING'                                EXISTING DRIVEWAY
  JOB NO.:   2020788
  SHEET NO.: 1
  DATED:     26/10/2020                                        CONTOUR


  EASEMENT A ON RP135782 LINEWORK
  DERIVED FROM QUEENSLAND SPATIAL                  PROPOSED DRIVEWAY SECTIONS DERIVED FROM
  CATALOGUE (QSPATIAL) DCDB.                       NOOSA COUNCIL CONTOUR INFORMATION
  DATED: 09/02/2021

                                                   CONTOUR INTERVAL: 1.0m
  THIS IS A SITE PLAN ONLY AND IS SUBJECT TO       CONTOUR INFORMATION DERIVED FROM 'NOOSA
  LOCAL AUTHORITY APPROVAL AND ENGINEERING         COUNCIL ENTERPRISE MAPPING SYSTEM' WEBSITE
  CONSTRAINTS.                                     MODULE:              PROPERTY RECREATION UTILITIES
  DISTANCES ARE APPROXIMATE ONLY AND               LAYER:               CONTOURS (1m)
  SUBJECT TO FINAL SURVEY.                         DATE DOWNLOADED: 08/04/2021

                                                                                                                                                  PROPOSED DRIVEWAY
 0               5         10           15           20        25 Metres                                                                           CROSS SECTION B-B1
                                                                                                                                                             SCALE 1:250
  Original Scale 1:250



DAVID WRIGHT HOUSE REMOVERS & DEMOLITION                                                 REVISION
                                                                                             -
                                                                                                     DATE
                                                                                                    080421
                                                                                                                     DESCRIPTION
                                                                                                                    FOR APPROVAL
                                                                                                                                             DRAWN CHECKED
                                                                                                                                               TT    AM
DWG NO. 21038.01.D        DATE 070521          SCALE 1:1000 @ A3       SHEET 4 OF 4         A       150421   UPD PROPOSED BLDG ENV & D'WAY     TT    AM
                                                                                            B       220421   UPDATED PROPOSED DRIVEWAY         TT    AM
                                                                                            C       300421   UPD ACCESS & TURNING AREA ADD     TT    AM

SITE PLAN - DRIVEWAY LONG SECTIONS                                                          D       040521    PRO DRIVEWAY SECTIONS ADDED      TT    AM
                                                                                                                                                             Sunshine Coast
                                                                                                                                                             tel. 07 5443 2844
                                                                                                                                                                                   [email protected]
OF LOT 7 ON RP838780                                                                                                                                                                www.ProjectUrban.com.au
                                                                                                                                                                                        Project Urban Pty Ltd
497 BLACK MOUNTAIN ROAD, BLACK MOUNTAIN QLD                                                                                                                                      ACN 608 895 923 ABN 97 608 895 923

Page 7

                             NORTH-EAST ELEVATION                                                                                                                NORTH-WEST ELEVATION




                                                                   THIS PLAN COINCIDES WITH         RL INFORMATION DERIVED FROM CONTOUR                          PROPOSED SECONDARY DWELLING LINEWORK          THIS IS A PROPOSAL PLAN ONLY
                                                                   SITE PLAN 21038.01 REVISION D.   INFORMATION FROM 'NOOSA COUNCIL                              DERIVED FROM LINEA DESIGN & DRAFTING          AND IS SUBJECT TO LOCAL
                                                                                                    ENTERPRISE MAPPING SYSTEM' WEBSITE                           PLAN:     PROPOSED SECONDARY DWELLING         AUTHORITY SUBDIVISION APPROVAL
 0       1       2       3   4      5                  10 Metres                                    MODULE:              PROPERTY RECREATION UTILITIES           JOB NO:    2020788                            AND ENGINEERING CONSTRAINTS.
                                                                                                    LAYER:               CONTOURS (1m)                           SHEET NO: 4                                   HEIGHTS ARE APPROXIMATE ONLY
  Original Scale 1:100                                                                              DATE DOWNLOADED: 08/04/2021                                  DATED:     26/10/2020                         AND SUBJECT TO FINAL SURVEY.



DAVID WRIGHT HOUSE REMOVERS & DEMOLITION                                                                                                       REVISION DATE
                                                                                                                                                   -    200521
                                                                                                                                                                            DESCRIPTION
                                                                                                                                                                           FOR APPROVAL
                                                                                                                                                                                               DRAWN CHECKED
                                                                                                                                                                                                 TT    AM
DWG NO. 21038.02                 DATE 200521   SCALE 1:100 @ A3    SHEET 2 OF 2


PROPOSED SECONDARY DWELLING ELEVATIONS WITH APPROXIMATE RL SHOWN                                                                                                                                               Sunshine Coast
                                                                                                                                                                                                               tel. 07 5443 2844
                                                                                                                                                                                                                                     [email protected]
OF LOT 7 ON RP838780                                                                                                                                                                                                                  www.ProjectUrban.com.au
                                                                                                                                                                                                                                          Project Urban Pty Ltd
497 BLACK MOUNTAIN ROAD, BLACK MOUNTAIN QLD                                                                                                                                                                                        ACN 608 895 923 ABN 97 608 895 923

Page 8

                             SOUTH-WEST ELEVATION                                                                                                                SOUTH-EAST ELEVATION




                                                                   THIS PLAN COINCIDES WITH         RL INFORMATION DERIVED FROM CONTOUR                          PROPOSED SECONDARY DWELLING LINEWORK          THIS IS A PROPOSAL PLAN ONLY
                                                                   SITE PLAN 21038.01 REVISION D.   INFORMATION FROM 'NOOSA COUNCIL                              DERIVED FROM LINEA DESIGN & DRAFTING          AND IS SUBJECT TO LOCAL
                                                                                                    ENTERPRISE MAPPING SYSTEM' WEBSITE                           PLAN:     PROPOSED SECONDARY DWELLING         AUTHORITY SUBDIVISION APPROVAL
 0       1       2       3   4      5                  10 Metres                                    MODULE:              PROPERTY RECREATION UTILITIES           JOB NO:    2020788                            AND ENGINEERING CONSTRAINTS.
                                                                                                    LAYER:               CONTOURS (1m)                           SHEET NO: 4                                   HEIGHTS ARE APPROXIMATE ONLY
  Original Scale 1:100                                                                              DATE DOWNLOADED: 08/04/2021                                  DATED:     26/10/2020                         AND SUBJECT TO FINAL SURVEY.



DAVID WRIGHT HOUSE REMOVERS & DEMOLITION                                                                                                       REVISION DATE
                                                                                                                                                   -    200521
                                                                                                                                                                            DESCRIPTION
                                                                                                                                                                           FOR APPROVAL
                                                                                                                                                                                               DRAWN CHECKED
                                                                                                                                                                                                 TT    AM
DWG NO. 21038.02                 DATE 200521   SCALE 1:100 @ A3    SHEET 1 OF 2


PROPOSED SECONDARY DWELLING ELEVATIONS WITH APPROXIMATE RL SHOWN                                                                                                                                               Sunshine Coast
                                                                                                                                                                                                               tel. 07 5443 2844
                                                                                                                                                                                                                                     [email protected]
OF LOT 7 ON RP838780                                                                                                                                                                                                                  www.ProjectUrban.com.au
                                                                                                                                                                                                                                          Project Urban Pty Ltd
497 BLACK MOUNTAIN ROAD, BLACK MOUNTAIN QLD                                                                                                                                                                                        ACN 608 895 923 ABN 97 608 895 923

Page 9

 PLANNING ACT – 2016
Date:           18/12/2020

ZĞĨĞƌĞŶĐĞEŽ͗ RAB20/0253
   This Plan Accompanies the
 Concurrence Agency Response


[OCR of page images]
 

NOTE:

1. WATER CLOSET DOORS OPENING INWARDS TO BE FITTED
WITH LIFT OFF HINGES & BE FITTED TO ALLOW THE DOOR
TO BE REMOVED WHEN IN THE CLOSED POSITION

2. PROVIDE SMOKE ALARMS IN ACCORDANCE,

WITH THE B.C.A. PART 3.7.2

 

 

NOTE:

EXISTING REMOVAL DWELLING.
EXISTING PINE TIMBER FRAME.
EXISTING UPPER FLOOR BRACING TO
COMPLY WITH AS 1684.2-2010

 

 

 

75
7

 

 

[540

2700

2780

75
75 “|

 

 

910 |[620|

7855
91
75
75

 

 

3325
3325

75
75

 

 

 

 

 

/_- EXISTING WALL LAYOUT PLAN

Yo) SCALE -1 : 100

 

 

 

 

 

 

|, 1300 2250 11055 1435
!
2250 3550 2510 1500 _ || 3120
75 75 75 1175 75
1585 || 4215 2510 885 || 2670 | 2500
175 75 75 75 175

 

 

 

 

 

 

 

 

 

 

 

 

 

  

 

 

 fridgel

     

 

 

 

 

 

PLANNING ACT — 2016

Date: 18/12/2020
Reference No: RAB20/0253

This Plan Accompanies the
Concurrence Agency Response

2320 \) 1910 |j
!

{75

3325

 

 

7095

2670

990 ||

 

 

 

75 75

2250 9990

75 “75
2500

 

 

 

 

 

     

p 54 929 655

f 54 929 659

m 0438 871 237

e [email protected]

LINEA

PESIGN # PRAFTING

This grawing shall remain the
roperty of Linea Design & Drafting

and Sd

and shall not be copied in whole
or in part without written approval
of the author.

©COPYRIGHT

PROJEC

   

" PROPOSED SECONDARY DWELLING

P.& A. SCIVYER

497 BLACK MOUNTAIN ROAD
BLACK MOUNTAIN

CLIENT

ADDRESS

JOB No.

2020788

 

SHEET No.

02

 

 

Date 26 OCT. 2020 Scale 1:100 Drawn AJL

QBCC:1139817

 

 

LP: SIP =

“7 House Removers & Demolition

a - House Removing - Demolition - Asbestos Removal -

ph: 07 38882234
240 Bruce Hwy Eastern Service Road, Burpengary East
www.davidwright.com.au

 

Page 10

 PLANNING ACT – 2016
Date:           18/12/2020

ZĞĨĞƌĞŶĐĞEŽ͗ RAB20/0253
   This Plan Accompanies the
 Concurrence Agency Response


[OCR of page images]
 

NOTE:
1. WATER CLOSET DOORS OPENING INWARDS TO BE FITTED

WITH LIFT OFF HINGES & BE FITTED TO ALLOW THE DOOR

 

 

TO BE REMOVED WHEN IN THE CLOSED POSITION 6)
2. PROVIDE SMOKE ALARMS IN ACCORDANCE,

WITH THE B.C.A. PART 3.7.2 4
NOTE:

EXISTING REMOVAL DWELLING. ELEVATION KEY

EXISTING PINE TIMBER FRAME.
EXISTING UPPER FLOOR BRACING TO
COMPLY WITH AS 1684.2-2010

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

    
          
 
    

 

 

 

 

 

 

  
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

| 1300 2250 11055 1435
2250 3550 2510 1500 _ | 3120
75 75 75 {| 75 75
1585 || 4215 2510 885 | 2745 | 2500
4175 75 75 475 4
wo 09.24sw 0906sw lo
ny ~ —_ OOO TT OTT OD ~~
Tio 1 *
wo 3
{oF °o 2
. Wigs | s| 8
zg | Bedroom 2 »
8 3 Bedroom 1 | ah
6 Snfoke L
N | = Aan
Smok 3
= ham ® = 3 S
e Ge < | “Is
t iN So
B smok 3 S
2 a 0 = wo Alam: 2 | >=
= 1—— Line of existing wall PLAN NING ACT _ 20 16
removed 2 ‘9
2 Ny
1, 5
| i 8 Date: 18/12/2020
lo lo 8 1—— New 100x100 hwd posts.
g| 8 3 | pasion oes a: Ref No: RAB20/0253
o o | columns below. © ererence NO:
New 150x42 LVL 15 % . .
| beam over-Continuous. ~ lo This Plan Accompanies the
re Je [! 1 | 2im12 bolts to each post. _ = Concurrence Agency Response
Remove hi Noosa Plan 2020
‘emove hip roof over.
1585 | 7160 5845 A03
A secondary dwelling:
75 ry dwelling
(| 600 a) has a maximum gross floor area of 65m?;
6495 | 2645 b) has no more than 2 bedrooms;
75 75 | 100 c) does not occur on any property covered by a Building Unit Plan; and
| 4300 2250 6645 3345 2500 d) does not occur on a property that already contains a dual occupancy or secondary dwelling.

 

 

 

Gross floor area
gross floor area for a building, means the total floor area of all storeys of the building, measured from the
outside of the external walls and the centre of any common walls of the building, other than areas used for—

 

 

 

 

 

 

 

 

FLOOR AREAS a) building services, plant or equipment; or

TT b) access between levels; or

LIVING AREA: 65.00 m? c) a ground floor public lobby; or

PORCH AREA: 16.70 m? d) a mall; or
(- > P RO POS E D P LAN DECK AREA: 34.00 m? e) parking, loading or manoeuvring vehicles; or

. 2 f) unenclosed private balconies, whether roofed or not.
Yo) SCALE -1: 100 TOTAL AREA: 115.70 m’
Noosa Shire Planning Scheme - Definitions

 

 

 

PROJEC

        

p 4 920655 " PROPOSED SECONDARY DWELLING /"°**

y
i CLIENT 2020788 5) a se Dodvi Aa en
LINEA mn o438 871 237 P. & A. SCIVYER Or a $4 House Removers & Demolition

497 BLACK MOUNTAIN ROAD

 

ESIGN = PRAFTING
BESIDE RETIN: ne seine ara BLACK MOUNTAIN 03 ph: 07 38882234
and shall not be copied in whole .
or in part without written approval 240 Bruce Hwy Eastern Service Road, Burpengary East
©COPYRIGHT Date 26 OCT. 2020 Scale 1:100 Drawn AJL QBCC:1139817 www.davidwright.com.au

 

 

 

 

 

Page 11

                     ATTACHMENT 2
 Planning Scheme Code Assessment:
          Low Density Housing Code
Regional Infrastructure Overlay Code

Page 12

Table 9.3.1.3 - Criteria for assessment

Location 9.3.1.3 Criteria for assessment (part)



Performance outcomes                                    Acceptable Outcomes                                 Compliance
Location
PO1                                                     AO1.1                                           Not relevant to this application.
Dwelling houses, rooming accommodation,                 Dwelling houses (including secondary dwellings)
community residences and short-term                     and community residences are anticipated in the
accommodation (for holiday homes) are                   Low density residential zone, Rural residential
located where they:                                     zone and Rural zone.

 1.   provide a high level of comfort and amenity for AO1.2
      occupants;                                      Rooming accommodation provides housing
 2.   maintain amenity and privacy of neighbouring choice within urban boundaries.
      premises;
 3.   are compatible with the character and
      streetscape of the local area; and
 4.   do not occupy land intended for higher density
      living.

Effects of Use 9.3.1.3 Criteria for assessment (part)

Performance outcomes                                    Acceptable Outcomes                                  Compliance
Effects of Use
Removal homes                                           AO2.1                                                Complies with A02.1
PO2                                                     Any part of a removal home that is affected by       The proposed removal home is in good condition and free from
A removal home—                                         termite attack, borers, dry rot or severe            termite attack, borers, dry rot and severe weathering.
                                                        weathering or is damaged as a consequence of
 1.   does not have an adverse impact on the            relocation, is repaired or replaced using new or
      amenity of the premises or surrounding            sound second-hand materials.
      premises; and
 2.   maintains the safety of people and property.      AO2.2                                                Not relevant to this application.
                                                        Where located within the urban boundary,
                                                        external surfaces of the building are cleaned and
                                                        painted.

Page 13

Performance outcomes                                  Acceptable Outcomes                                 Compliance
                                                      Editor’s Note— the urban boundary is indicated
                                                      on the zone maps contained within Schedule 2.

                                                      Editor’s Note— applicants will be required to pay
                                                      a performance bond to Council before
                                                      final building approval is granted. The bond is
                                                      held by Council until all external building works
                                                      are completed to a satisfactory level, usually
                                                      within a 12 to 24 month time frame.

Housing choice                                                                                            Complies with A03.
PO3                                                   AO3                                                 The proposed secondary dwelling has a maximum gfa of 65m2 and
A secondary dwelling:                                 A secondary dwelling:                               contains two (2) bedrooms. It is noted gfa excludes unenclosed
                                                                                                          private balconies, whether roofed or not. The land is not covered
 1.   forms part of a dwelling house and is not        1.   has a maximum gross floor area of 65m²;       by a Building Unit Plan and only contains a single dwelling house.
      subdivided from the balance of the dwelling      2.   has no more than 2 bedrooms;
      house;                                           3.   does not occur on any property covered by
 2.   contributes to housing choice for members of          a Building Unit Plan; and
      the one household;                               4.   does not occur on a property that already
 3.   protects the low density residential, rural           contains a dual occupancy or secondary
      residential or rural character of the zone;           dwelling.
 4.   does not occur on a property covered by
      a Building Unit Plan or any property already
      containing more than one dwelling;
 5.   is accompanied by sufficient car parking.
PO4                                                    AO4                                                Not relevant to this application.
Rooming accommodation is located on a site with        Rooming accommodation provides housing
convenient access to employment or education as        choice within urban boundaries is limited to sites
well as goods and services including public transport. within:

                                                       1.   1,500 metres walking distance, via a sealed
                                                            pathway, of land within the Major centre
                                                            zone, District centre zone or 800 metres of
                                                            land within the Neighbourhood centre zone;
                                                            or
                                                       2.   800 metres walking distance, via a sealed
                                                            pathway of a pedestrian access point of
                                                            a hospital or tertiary education
                                                            establishment; or
                                                       3.   400 metres walking distance, via a sealed
                                                            pathway, of a Translink bus stop.

Page 14

Building design and services 9.3.1.3 Criteria for assessment (part)

Performance outcomes                                   Acceptable Outcomes                                  Compliance
Building design and services
Service and utilities
PO5                                                    AO5.1                                             Not relevant to this application.
Development is provided with:                          If located within the urban boundary,
                                                       the dwelling is connected to reticulated water
 1.   a level of infrastructure and services that is   supply, sewerage, stormwater drainage and
      appropriate to its setting and sufficient for thetelecommunications infrastructure networks (where
      intended use;                                    available to the lot).
 2.   an effluent treatment and disposal system that
      does not have an adverse effect on ecologically Editor’s Note—the urban boundary is indicated on
      important areas or water quality; and             the zone maps contained within Schedule 2.
 3.   adequate onsite water storage to support the
      efficient use of water and is adequate for        AO5.2
      everyday use of the occupants.                    Where there is no reticulated water supply, the     Can be conditioned to comply with A05.2.
                                                        premises is serviced with a rainwater tank with the
                                                        following minimum water supply capacity:

                                                        1.   for dwellings with no more than 3 bedrooms –
                                                             45,000 litres; or
                                                        2.   for dwellings of more than 3 bedrooms or
                                                             where including a secondary dwelling on the
                                                             same premises – 60,000 litres.

                                                       AO5.3                                                 Not relevant to this application.
                                                       If located on a lot where reticulated sewerage is not
                                                       available to the lot, the dwelling is connected to an
                                                       on-site effluent treatment and disposal system.
Landscaping                                                                                                 Not relevant to this application.
PO6                                                     AO6
Buildings and structures allow for sufficient space for Soft landscaping is provided and retained to a
outdoor activities, garden areas and screening to       minimum of 20% of the site area.
surrounding land uses.

Car parking                                                                                                 Not relevant to this application.
PO7                                                    AO7
Sufficient car parking is provided to accommodate      Car parking is provided in accordance with Table
the number of vehicles likely to use the site.         9.4.1.4 of the Driveways and parking code.
Driveway and crossover

Page 15

Performance outcomes                                Acceptable Outcomes                                  Compliance
Editor’s Note—In addition to the following benchmarks for accepted development subject to requirements for driveway and crossovers, approval is required from Council
to construct or modify all crossovers.
Access Design                                                                                            Can be conditioned to comply with A08.1
PO8                                                 AO8.1                                                A new driveway crossover is proposed to provide access to the
The design, management and maintenance of           Driveways and crossovers are designed to comply      dwelling house from Easement B in Lot 6 RP 838780. The
the access facilitates:                             with Council's standard drawings RS-049, RS-         driveway and crossover will be designed to comply with Council’s
                                                    050, RS-056 and addendum as applicable.              standard drawing.
 1.   safe and convenient use for vehicles,
      pedestrians and cyclists;                     AO8.2                                                Not relevant to this application – there is no footpath.
 2.   vehicles negotiating without contacting the   Where a footpath exists, the driveway meets
      driveway or crossover surface; and            the road reserve at the level of the existing
 3.   stormwater disposal without any negative      footpath.
      impacts on the surrounding area.
                                                    AO8.3                                                Complies with A08.3
                                                    Driveways within the property:                       The attached long-section (refer Attachment 1) has been derived
                                                                                                         from levels from Council’s mapping and shows that the new
                                                     1.   have a maximum gradient of 20% and vertical driveway has reasonable longitudinal grades ranging from 7% to
                                                          curves to ensure no scraping for a standard    13.6% and will therefore function satisfactorily.
                                                          vehicle; or
                                                     2.   have a maximum gradient of 25% provided–
                                                            1. the length of the driveway steeper than
                                                                 20% does not exceed 6 metres; and
                                                            2. there is a change in gradient not less
                                                                 than 2 metres in length and not greater
                                                                 than 12:5% at the ends of the 25%
                                                                 section of the driveway.
PO9                                                 AO9                                                  Complies with A09
The driveway and crossover design avoids using      The driveway and crossover is designed without       The proposed driveway and crossover is from land contained
structures within the road reserve.                 significant alteration to the existing road          within an access easement and does not require any alteration to
                                                    reserve whereby the finished surface level of the    the road reserve.
                                                    driveway is consistent in height with the existing
                                                    height of the road reserve.

                                                    Editor’s Note—Should the design not comply with
                                                    the standard drawings, including any cut or fill
                                                    within the road reserve, an operational works
                                                    application to Council for a non-standard driveway
                                                    is required.
Materials                                                                                                Not relevant to this application.
PO10                                                AO10
Driveways and crossovers are to be able to          No pavers or permeable pavement systems are

Page 16

Performance outcomes                                   Acceptable Outcomes                                   Compliance
withstand loadings from vehicles and the use of        used within the road reserve.
pavers is avoided.
                                                       Editor’s Note—Examples of the types of pavers to
                                                       avoid include clay, concrete and permeable
                                                       pavement products.
Surface water                                                                                                Not relevant to this application.
PO11                                                   AO11
Driveways are designed to:                             Driveways have a minimum grade of 1% away from
                                                       any adjoining buildings and are formed to drain to
 1.   prevent water from ponding or entering           landscaped areas.
      buildings;
 2.   provide an opportunity for filtering of
      stormwater prior to it leaving the site; and
 3.   not reduce the stormwater carrying capacity of
      roadways.
Protection of infrastructure                                                                              Complies with A012
PO12                                                   AO12                                               Stormwater infrastructure is not located within 1m of the
Driveways do not damage or interfere with the          Driveways are located not less than 1.0 metre from proposed driveway.
location, function of, or access to Council            stormwater infrastructure.
infrastructure.
                                                       Editor’s Note—If the driveway covers or is within
                                                       1.0 metre of stormwater infrastructure, an
                                                       operational works application to Council for a non-
                                                       standard driveway is required.
Streetscape and effect on traffic network                                                                    Can be conditioned to comply with A013.1
PO13                                                   AO13.1
The visual impact of driveways on the streetscape      Areas adjoining driveways disturbed as a result of
and surrounding area is minimised and significant      the driveway construction are grassed or planted to
adverse impacts on the traffic network are avoided.    minimise visual impact and stabilise the soil.

                                                       AO13.2                                                Complies with A013.2
                                                       Vehicular access avoids disturbance to the tree       Vehicular access has been sited to ensure no clearing of
                                                       protection zone of trees on public land.              vegetation is required.
Driveway Location                                                                                        Complies with A014.1
PO14                                                AO14.1                                               One driveway and crossover is provided directly from the road
Driveways and crossovers are located so they do not Only one driveway and crossover is provided.         reserve while a second driveway will be provided for the
impede the safe and efficient use of the road                                                            secondary dwelling from a rear access handle within an easement.
network.                                            AO14.2
                                                    Where the premises has frontage to more than one Not relevant to this application.
                                                    formed and sealed road and the roads have
                                                    differing orders in the Road Hierarchy, the driveway

Page 17

Performance outcomes                                   Acceptable Outcomes                                    Compliance
                                                       and cross-over is provided on the frontage with the
                                                       lower order.

                                                       AO14.3                                                 Not relevant to this application.
                                                       For corner lots, driveways and crossovers are
                                                       located in accordance with Council's standard
                                                       drawings.

                                                       AO14.4                                                 Complies with A014.4
                                                       If in the Rural zone or Rural Residential zone, the    The driveway is not located in road reserve however has been
                                                       driveway and cross-over is located to provide          located to achieve safe sight distances.
                                                       minimum safe sight distances in accordance with
                                                       Austroads.

                                                       Editor's Note - An operational works application is
                                                       required for a second driveway.
Bushfire Hazard Management                                                                                     Complies with A015
PO15                                                    AO15                                                   The site is located within a Potential impact buffer area and has
Where located in a Bushfire Hazard Area as shown        Within a bushfire hazard area where there is no        access to on-site water tanks and a swimming pool for firefighting
on the Bushfire Hazard Overlay Map in Schedule 2        reticulated water supply, the premises has:            purposes. The secondary dwelling will also be provided with a
and not in a water service area, an adequate, reliable,                                                        tank for water supply and will also be fitted with a standard fire
safely located and freely accessible water supply is     1. an accessible dam, swimming pool or water          brigade fitting.
provided for fire fighting purposes, which is in              tank available for firefighting purposes with an
addition to day to day water supply.                          onsite water volume of not less than 5,000
                                                              litres; and
                                                         2. a water supply outlet pipe 50 millimetres in
                                                              diameter and fitted with a standard fire
                                                              brigade fitting connected to the water supply
                                                              (other than where the water supply is in a
                                                              swimming pool or dam).

                                                       Editor’s Note — Water supply capacity for
                                                       firefighting purposes is in addition to water supply
                                                       capacity for household use.
Flood Hazards                                                                                                  Not relevant to this application.
PO16                                                   AO16.1                                                  The site is not located in the Flood Hazard Area.
Development is designed and sited to ensure risk to    Where the development is located in the Flood
people and property from flooding is avoided or        Hazard Area as shown on Flood Hazard Overlay
minimised.                                             Map in Schedule 2,
                                                       the finished floor level of habitable rooms is at least
                                                       300 millimetres above the Defined flood event
                                                       (DFE).

Page 18

Performance outcomes                                 Acceptable Outcomes                                       Compliance

                                                     OR

                                                     AO16.2
                                                     Where the DFE has not been modelled for the area,
                                                     the finished floor level of habitable rooms is at least
                                                     500 millimetres above the highest recorded flood.

                                                     Editor's Note—The QDC mandatory provisions
                                                     MP3.5 also apply to the construction of buildings in
                                                     flood hazard areas.
PO17                                                                                                           Not relevant to this application.
Underground car parking areas are designed to        No acceptable outcome provided
drain and function safely during a flood event and
power failure.

Editor's note—Basements should have flood
immunity above the 1%AEP defined flood event with
alternative means to mechanical pumping used to
achieve such immunity.
Major Electricity Infrastructure & Substations                                                             Alternate solution proposed to A018.1
PO18                                                   AO18.1                                              The secondary dwelling is setback 27.9m from the transmission
Development is sufficiently separated from major       Development including any sensitive land uses is at line easement. The proposed secondary dwelling is setback
electricity infrastructure and substations to minimise least:                                              greater than 58m (approx.) from the overhead lines. The proposed
the likelihood of nuisance or complaint.                                                                   siting of the secondary dwelling clearly provides adequate
                                                        1. 50 metres from a transmission substation;       separation and does not compromise the operation of the
                                                        2. 10 metres from any other substation; and        electricity infrastructure. Compliance is therefore achieved with
                                                        3. 30 metres from a transmission line easement. PO18.

                                                     AO18.2
                                                     Habitable buildings are not located within an
                                                     easement for a distribution line.
PO19                                                 AO19                                                      Not relevant to this application
Development is located and designed to avoid or      Noise emissions do not exceed 5db(A) above                There is no noise associated with the overhead electricity
minimise noise nuisance from the use of              background noise level internal to a                      infrastructure.
infrastructure.                                      habitable building measured in accordance with
                                                     AS1055.
PO20                                                 AO20                                                  Not relevant to this application.
Wherever practicable habitable buildings are         Where adjoining substations or major electricity
orientated to avoid direct overlooking of major      infrastructure, habitable buildings are orientated so
electricity infrastructure or substations.           that the majority of outdoor living areas and

Page 19

Performance outcomes                                     Acceptable Outcomes                                  Compliance
                                                         windows of habitable rooms face away from
                                                         the infrastructure.
Earthworks and Drainage                                                                                       Not relevant to this application.
PO21                                                     AO21                                                 Minimal earthworks are proposed. The proposed secondary
Earthworks and drainage operational works do not         Filling other than accessways:                       dwelling will be transported to the site and sits on a stumps.
directly, indirectly or cumulatively cause adverse
impacts external to the development site by:              1.   does not extend more than the equivalent of
                                                               3 metres around the main building, measured
 1.   causing ponding of water on the site or nearby           from the outer walls of the building;
      land;                                             2.     is limited to a maximum of 500m2; and
 2.   increasing flooding, which adversely affects the 3.      does not impact on the local drainage of
      safety or use of any land upstream and                   adjoining properties.
      downstream;
 3.   adversely affecting the flow of water in any
      overland flow path; and
 4.   adversely affecting the privacy or visual amenity
      of surrounding property.

Editor's Note—Development should ensure that
filling does not impact on the amenity and usability
of neighbouring properties (including loss of privacy
caused by relative level changes) or offsite drainage.
Landslide Hazard Area                                                                                         Not relevant to this application.
PO22                                                     AO22.1                                               The proposed secondary dwelling, including associated access is
Development maintains the safety of people,              Development, including associated access, is not     located outside the moderate, high and very high landslide hazard
property and hazardous materials stored in bulk          located on land identified as a landslide hazard     areas on the Landslide Hazard Overlay Map. Please refer to
from the risk of landslide.                              area on a Landslide Hazard Overlay Map.              Drawing No 21038.01D, Sheet 3 of 4 at Attachment 1 for
                                                                                                              confirmation.
                                                         AO22.2
                                                         Development, including associated access, is
                                                         located outside moderate, high and very high
                                                         landslide hazard areas and areas with 15% slope or
                                                         greater, as determined by a site-specific slope-
                                                         analysis.

                                                         Editor's Note—A site- specific geotechnical
                                                         assessment may be used to demonstrate that
                                                         although the proposed development is shown on
                                                         the Landslide Hazard Overlay as being in the
                                                         moderate, high or very high landslide hazard area,
                                                         the landslide risk is low or very low.

Page 20

Performance outcomes   Acceptable Outcomes                                      Compliance
                       OR

                       AO22.3
                       A site-specific geotechnical assessment is prepared
                       by a registered professional engineer to certify that:
                        1. the stability of the site, including associated
                             buildings and infrastructure, will be
                             maintained and operational for the life of the
                             development;
                        2. the site is not subject to the risk of landslide
                             activity originating from other land, including
                             land above the site; and
                        3. development of the site will not increase the
                             risk of landslide activity on other land.

                       Editor's Note— PSP8 Natural Hazards provides
                       further guidance on assessing landslide hazard.

                       AO22.4
                       Any specific measures identified in a site specific
                       geotechnical assessment for stabilising the site or
                       development are to be fully implemented.
                           You have reached the end of the page.

Page 21

Table 8.2.9.4 Criteria for assessable development - Gas pipeline and Major Electricity Infrastructure


Performance outcomes                               Acceptable outcomes                                    Compliance

Gas pipeline corridor and buffer area
PO1                                                AO1.1                                                Not relevant to this application.
Development, including uses and works are          Buildings and structures are setback a minimum of 40 The site is not in a gas pipeline corridor and buffer area on the
constructed and operated to avoid:                 metres from a gas pipeline corridor.                 Regional Infrastructure Overlay Map.

 1.   compromising the viability of the gas        AO1.2
      pipeline corridor; or                        The use does not involve the storage of flammable,
 2.   damaging or adversely affecting the          explosive or other hazardous materials within 200
      existing or future operation of a gas        metres of the gas pipeline corridor.
      pipeline within the gas pipeline corridor.   OR

                                                   AO1.3
                                                   Written conformation of the pipeline license holder
                                                   of Petroleum Pipeline License 32 that
                                                   the setback distance and design of the development
                                                   does not impact the future use of the gas pipeline.

                                                   Editor's note- should a lesser setback distance be
                                                   proposed, it is recommended that the applicant
                                                   consult with the relevant gas pipeline manager prior
                                                   to the lodgement of a development application to
                                                   determine how compliance with the performance
                                                   outcome can be achieved.

Page 22

Performance outcomes                                  Acceptable outcomes                                   Compliance

Major Electricity Infrastructure

PO2                                                                                                         Complies with PO2.
Development does not increase risk to                 No acceptable outcome provided                        The electricity transmission line corridor is 119m wide. The
community health or safety, or the operation                                                                proposed secondary dwelling is setback 27.9m from the
and reliability of major electricity infrastructure                                                         easement and greater than 58m (approx.) from the overhead
                                                                                                            lines and will not increase risk to community health or safety or
                                                                                                            the operation of the electricity infrastructure.
PO3                                                   AO3.1                                                 Alternate solution to A03.1 proposed
Development involving a sensitive land use is         With the exception of class 10 buildings, buildings   The secondary dwelling is setback 27.9m from the transmission
sufficiently separated from major electricity         associated with a sensitive land use maintain         line easement. The proposed secondary dwelling is setback
infrastructure and substations to minimise the        a setback of at least:                                greater than 58m (approx.) from the overhead lines. The
likelihood of nuisance or complaint.                                                                        proposed siting of the secondary dwelling clearly provides
                                                                                                            adequate separation and does not compromise the operation
                                                       a) 50 metres from a transmission substation;         of the electricity infrastructure.
                                                       b) 10 metres from any other substation; and
                                                       c) 30 metres from a transmission line easement.


                                                      AO3.2                                                 Complies with A03.2
                                                      Buildings are not located within an easement for a    The proposed secondary dwelling is not located within the
                                                      distribution line.                                    easement.

PO4                                                   AO4                                                   Not relevant to this application. The proposed secondary
Development adjoining substations are located         For development adjoining substations, noise          dwelling does not adjoin a substation.
and designed to avoid noise nuisance from             emissions do not exceed 5db(A) above background
infrastructure.                                       noise level at the sensitive receptor of
                                                      a building associated with a sensitive land use,
                                                      measured in accordance with AS1055.

PO5                                                   AO5                                                 The majority of the site is occupied by easement containing
Wherever practicable new lots and buildings are       Buildings are orientated so that the majority of    overhead electricity lines running through the site in a
orientated to avoid direct overlooking of             outdoor living areas and windows of habitable rooms north/south direction. It is not possible to avoid direct
electricity infrastructure.                           face away from towers or other major electricity    overlooking of electricity infrastructure.
                                                      infrastructure.

Page 23

PO6                                                  AO6                                                   Not relevant to this application. There are no poles or towers
For sensitive land uses, there is sufficient space   A minimum 3 metres wide densely planted               that need to be screened.
within the site to establish landscaping which       landscaped buffer is provided along the boundary
substantively screens and softens poles, towers,     adjoining the electricity infrastructure, including
or other structures and equipment associated         provision for advanced trees and shrubs that will
with major electricity infrastructure and            grow to a minimum height of 10 metres.
substations.
                                                     Editor's note- Applicants may find guidance in
                                                     Powerlink Queensland's brochure
                                                     "Using Vegetation to screen transmission
                                                     lines". Applicants should also note
                                                     that vegetation will need to maintain statutory
                                                     clearances.

PO7                                                  AO7.1                                                 Not relevant to this application. Planting of additional
Vegetation does not pose a risk to the safety or     Vegetation planted within the easement of an          vegetation within the easement in not warranted as a result of
reliability of electricity infrastructure.           overhead powerline or, where there is no easement,    this application.
                                                     the area of influence of a powerline, has a mature
                                                     height of no more than 3.5 metres.

                                                     AO7.2                                                 Not relevant to this application.
                                                     Vegetation planted within an underground powerline
                                                     easement does not have a mature root system in
                                                     excess of 150 millimetres in depth and is not located
                                                     directly over the powerline.

                                                     AO7.3                                                 Not relevant to this application. Existing vegetation is
                                                     Regardless of the width of the                        maintained adjoining the easement to ensure it does not pose
                                                     easement, vegetation adjoining easements must be      a risk to the safety or reliability of electricity infrastructure.
                                                     separated from the power pole or other
                                                     infrastructure by a distance at least equal to the
                                                     maximum mature height of the vegetation.

PO8                                                  AO8.1                                                 Complies with A08.1
Any earthworks are undertaken in a way which:        For overhead distribution infrastructure, no          There will be no earthworks undertaken within 10m of a tower,
                                                     earthworks are undertaken within 10 metres of a       pole or stay.
a) ensures stability of the land on or adjoining     tower, pole or stay.
   the electricity infrastructure;
b) does not otherwise impact on the safety and AO8.2                                                       Complies with A08.2
   reliability of the electricity infrastructure; and For overhead transmission infrastructure, no         There will be no earthworks undertaken within 20m of a tower,
c) does not restrict the placement or use of the earthworks are undertaken within 20 metres of a           pole or stay.
   electricity infrastructure provider's equipment. tower, pole or stay.

Page 24

PO9                                                AO9.1                                                 Complies with A09.1
Services and infrastructure works (such as         Underground services are not located within 20        Underground services will not be located within 20m of a tower,
stormwater, sewerage, water and the like) do       metres of a tower, pole, stay or substation boundary. pole, stay or substation boundary.
not impact on the safety and reliability of
substations or major electricity infrastructure.   AO9.2                                                   Complies with A09.2
                                                   No valve pits occur within:                             There will be no valve pits within 20 or 60m of the electricity
                                                                                                           infrastructure.
                                                    a)   for transmission infrastructure, 60 metres of a
                                                         tower, pole or stay; or
                                                    b)   for distribution infrastructure, 20 metres of a
                                                         tower, pole or stay.

                                                   AO9.3                                                 Complies with A09.3
                                                   Underground services traversing an easement cross There are no underground services traversing the easement.
                                                   at right angles to the overhead or underground lines.