Approved Plans - OPW21/0160 - Engineering Plans - 9 Butler St, Tewantin
Plans and drawings
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn LEGEND
DIAL1100
BEFORE YOU DIG EXISTING SEWER
EXISTING ABANDONED SEWER
EXISTING COMBINE DRAIN
DRIVEWAY
TURNAROUND AREA EXISTING TELSTRA
EXISTING OPTIC FIBRE
EXISTING WATER
EXISTING STORMWATER
EXISTING FOUL WATER
EXISTING GAS
Y
TC
E
IC
LR
T
H
IO
N
/G
S
ITE
X
I
Y
TC
E
IC
LR
T
G
IU
N
/G
S
ITE
X
I
EXISTING KERB INVERT
EXISTING CONTOURS
DESIGN CONTOURS
PROPOSED KERB
PROPOSED ROAD ℄
PROPOSED DRIVEWAY
P
R
O
PO
S
T
S
E
R
DM
WA
E
T
R
PROPOSED SEWER
SEWER TO BE ABANDONED
PROPOSED WATER
PROPOSED RETAINING WALL
PROPOSED FENCE
SECTION OF EXISTING
PROPOSED DOWEL JOINT
CROSSOVER TO REMOVED
PROPOSED SAWCUT JOINT
PROPOSED WATER CONDUIT
PROPOSED ELECTRICAL CONDUIT
WIDENING OF EXISTING
PROPOSED TELECOM CONDUIT
CROSSOVER TO BETTER ALIGN
WITH PROPOSED DRIVEWAY EXISTING SPOT LEVEL
VISITOR PARKING PROPOSED SPOT LEVEL
SPACE
WARNING
BEWARE OF UNDERGROUND SERVICES
The locations of underground services are approximate only.
It is the responsibility of the contractor to prove the
exact position of all services on site.
No guarantee is given that all existing services are shown.
Locate all underground services before commencement of works
DIAL 1100 BEFORE YOU DIG
www.1100.com.au
DRIVEWAY LAYOUT CUT 200mm LONG PIECE
REFER DETAIL
OUT OF EVERY 2nd 6mm SAW CUT
SCALE 1:100 A
WIRE 6
PROPOSED ROADSEAL SL JOINT
SEALANT RECESSED
DRIVEWAY
3mm BELOW SURFACE
30
LEVEL
CLOSED CELL
PROPOSED SLAB
SL72 MESH
REINFORCEMENT
SAW CUT JOINT (SJ) POLYETHYLENE BACKING
(N32) N.T.S. ROD
50mm COVER
50mm(MAX) SAW CUT JOINTS WITHIN 12
BEDDING SAND HOURS OF CASTING SLAB
DETAIL A
125
N.T.S.
SEALANT SL72 MESH
CONCRETE SLAB DETAIL - DRIVEWAY REFER DETAIL B WITH REINFORCEMENT
20
5
N.T.S. BACKING ROD 50mm COVER
75
1x50ØELECTRICAL CONDUIT 1x50Ø TELECOM CONDUIT
(WITH DRAW WIRES (WITH DRAW LINES
INSTALLED) INSTALLED) 75
10
50Ø CONDUIT
125
MINIMUM SEPARATION TO MINIMUM SEPERATION TO SEALANT
50
FOR 32Ø WATER ALL OTHER SERVICES ALL OTHER SERVICES - 25 EXPANSION BOND BREAKER
SERVICE CUP
BACKING ROD
300mm LONG R12 DOWEL BARS @
APPROVED PLANS
150 150 BOND
300mm CENTRES or 300mm LONG BREAKER
DRIVEWAY TYPICAL SECTION R16 DOWEL BARS @ 450mm FILLER FILLER
NOTE:
REFER TO TITLE SHEET 201102-T01 FOR DRAWING SCALE 1:20 OPW21/0160 CENTRES
INDEX & SITE LAYOUT. REFER TO NOTES SHEET
201102-N01 FOR ALL PROJECT NOTES. NOOSA COUNCIL DOWEL JOINT (DJ) DETAIL B
11 AUGUST 2021 N.T.S. N.T.S.
FILE: 201102.dwg DATE: 01-06-2021 USER: NATHANFLANDERS
-
XREFS: X_Design, X_Titleblock, X_Survey
FIRST DESIGN DRAWN CHECK APPROVED DATE STATUS SCALE CLIENT PROJECT DRAWING TITLE
AMENDMENT DETAILS All setting out should be carried
ISSUE
A
NF
NF
PM
PM
KS
KS KS 28.07.21 RFI RESPONSE ISSUED FOR APPROVAL
0 1 2 4 out in accordance with Council's
standard drawings or as
K. COURTNEY 9 BUTLER ST, TEWANTIN DRIVEWAY
A
M
E
nominated on hard copy plans.
Any digital information supplied by
OPERATIONAL WORKS LAYOUT PLAN
N
D
M
APPROVED this office is for information only.
Any discrepancies should be
DA No. RAL21/008 & DETAILS
E BY: A. K. Sani RPEQ 10697 PROJECT No. DRAWING No. REVISION
N discussed with the superintendent.
T
S
SIGN: DATE: 28.07.21
© Ferg & Roeds Consulting Pty Ltd
ABN 60 646 316 056
201102 DW01 A
D:\Projects\200701 11 O'Leary Ave, Burpengary\CAD\200701-rev1.dwg Plotted by: ###### on 11/18/2020 11:09:57 AM