BUNNINGS WAREHOUSE, NOOSAVILLE
SURFACE WATER MANAGEMENT PLAN J) Cardno
Runoff Generation Parameters
Parameter Urban Commercial
I Field Capacity (mm)
Residential
200 80
Infiltration Capacity Coefficient a 50 200
Infiltration Capacity Exponent b 1 1
Rainfall Threshold (mm) 1 1
Soil Capacity (mm) 400 120
Initial Storage (%) 10 25
Daily Recharge Rate (%) 25 25
Daily Drainage Rate (%) 5 5
t Initial Depth (mm) 50 50
Pollutant Export Relationships
Land Use Parameter Total Suspended Total Phosphorus Total Nitrogen
Source Solids (mg/L) i (mg/L) (mg/L)
Nodes
Base Storm Base Storm Base Storm
L_^Flow Flow Flow Flow Flow Flow
Urban Mean 0.10 2.18 -0.97 -0.47 0.20 0.26
Residential
Std Dev. 0.34 0.39 0.31 0.31 0.20 0.23
Commercial Mean 0.78 2.16 -0.60 -0.39 -0.32 0.37
Std Dev. 0.39 0.38 0.50 0.34 0.30 0.34
t
t
P
L
I
I Bunnings Warehouse
J \3501-54\WP\SWMP doc
Version 1
Commercial in Confidence
15 December 2006