Referral Agency Response - Planning RAP20 0036 · RAP20/0036

of 1

Text shows just the words. Original shows the document exactly as it was published.

Officer: 	Billy Glover
Direct Telephone: 	5329 6245
Our Reference:	RAP20/0036
Your Reference:	n/a
5 November 2020
JDBA Certifiers
PO Box 1365
MOOLOOLABA  QLD  4557

[email protected]
Dear Sir
Referral Agency Response
Planning Act 2016
I refer to your application and advise that Council, as a concurrence agency for the application, completed its assessment of the application on 23 September 2020. You are advised that Council requires conditions to be attached to any development approval. The conditions are listed below.
application details
Application No:	RAP20/0036
Street address:	30 Elanda Street Sunshine Beach Qld 4567
Real property description:	Lot 162 RP 48113
Planning Scheme:	The Noosa Plan (8 June 2018)
type of development
The applicant seeks the following type of development approval:
Concurrence Agency Response - Development Permit for Building Works (Detached House)
concurrence agency conditions
PLANNING
When Conditions must be Complied With
Unless otherwise stated, all conditions of this Decision Notice must be complied with prior to the use commencing, and then compliance maintained at all times while the use continues.
Approved Plans
Development undertaken in accordance with this approval must generally comply with the approved plans of development. The approved plans are listed in the following table unless otherwise amended by these conditions.

Plan No.	Rev.	Plan/Document Name	Date
DD-00	B	Ground floor Plan, prepared by kanvas design	24/09/2020
DD-01	B	Ground floor Plan, prepared by kanvas design	24/09/2020
DD-02	B	Upper floor Plan, prepared by kanvas design	24/09/2020
DD-03	B	Elevations, prepared by kanvas design	24/09/2020
DD-04	B	Elevations, prepared by kanvas design	24/09/2020
CW-03	A	Site Plan, prepared by Structures Engineering design	21/09/2020
Building Height
The maximum height of the development must not exceed 8.0 metres above the finished ground level and the natural ground surface.
Certification must be submitted to Council from a Licensed Surveyor which certifies that the building does not exceed the maximum height requirement of this Decision Notice.
Roof Form
Eaves must be minimum 600mm to the outermost projection.
Performance Bond
Security in the form of a cash bond or trading bank guarantee to the sum of $5000 must be submitted to Council, to secure performance of all conditions of this approval, prior to the issue of a Development Permit for Building Works or prior to the pre-start meeting. The cash bond or trading bank guarantee will be returned on performance of the conditions of approval less any costs incurred by Council in respect of enforcing performance of this permit. Council reserves the right to call upon the bond or guaranteed sum to effect compliance with conditions.
Landscaping
A minimum of 20% of the site must be retained as soft landscaping.
Existing trees on the site must be retained, except where required to be removed to accommodate the approved dwelling.
Where it is necessary to remove the existing street tree during construction of the driveway, the applicant must provide, at their cost, a replacement street tree suitable for placement beneath overhead power lines.  The replacement tree must be of a species agreed in writing by Council and planted in the verge fronting the site with the final location to be determined in consultation with Council’s landscape assessment officer prior to installation.
Trees to be retained must be protected from clearing or construction activities by:
clearly marking vegetation to be retained with flagging tape
installing protective fencing around the drip line of the vegetation
restricting stockpiling, storage and vehicle parking to those areas which are already cleared
using low impact construction techniques around vegetation.
The arbors in the rear courtyard and at the entrance gateway must be planted with soft, native climbing species capable of maintaining a minimum 50% foliage cover to soften the structural elements within the front and rear setbacks.  The arbour planting must be maintained at all times while the structure remains.
The rear courtyard within the 4.5m building setback area must comprise at least 50% soft landscaping and permeable paving to help minimise potential for noise to be deflected to nearby residences by hard surfaces.
Site Access and Driveways
A sealed access driveway must be provided from Elanda Street to all parking and manoeuvring areas of the development. The works must be undertaken generally in accordance with Council standard drawings RS-049 and RS-050.
The driveway must be constructed to grades that ensure that vehicles will not bottom out or scrap on the driveway or the road formation when entering and exiting the site.
Stormwater Drainage
The site must be provided with a stormwater drainage system connecting to a lawful point of discharge.  The works must be undertaken in accordance with a site specific Stormwater Management Plan (SWMP), prepared by a suitably qualified person.
The site specific SWMP must be approved as part of the subsequent Building Permit.
The site specific SWMP must be consistent with the site specific geotechnical report’s recommendations.
Easements
Unless otherwise agreed in writing by the relevant service provider, any public or third party infrastructure located on the subject site must be placed within an easement registered against the title of the property.
All easements must be designed in accordance with the planning scheme and granted at no cost to the Grantee.  Where the Grantee is Council or a service authority, the easement documentation must be in accordance with the Grantee’s standard easement terms.  Draft easement documentation must be submitted to Council for endorsement.
All works must be kept clear of any existing or proposed easements on the subject land, unless agreed otherwise in writing by the Grantee.
Earthworks and Retaining Walls
Earthworks carried out on site must not affect the structural integrity of any of the adjoining lands and/or buildings and/or structures and/or services.
All works must be carried out in accordance with a Geotechnical Report (or part thereof) prepared by a qualified person* and endorsed through the Building Permit. The geotechnical report must identify the building foundation requirements and stability considerations necessary for the stability of the subject site (and associated ancillary structures) and the adjoining properties for the longer term.
*(Refer to Advisory Notes)
The site specific geotechnical report must be consistent with the site specific SWMP’s recommendations.
All earthworks must be contained entirely within the subject site unless written permission from the respective landowner(s) is provided to Council. All earthworks must be undertaken in accordance with the provisions of Australian Standard AS3798: Guidelines on Earthworks for Commercial and Residential Developments.
Where the development involves excavation or filling over, or adjacent to, drainage, water supply or sewerage infrastructure, all access chamber surface levels must be adjusted to provide a freeboard of 100mm above the finished ground surface level.
All retaining walls must be designed and constructed in accordance with the planning scheme and must be certified by an RPEQ where exceeding 1.0m in height. All retaining walls that are publicly accessible and exceed 1.0m in height must be fitted with a commercial grade safety fence.
Damage to Services and Assets
Any damage caused to existing services and assets as a result of the development works must be repaired at no cost to the asset owner at the following times:
where the damage would cause a hazard to pedestrian or vehicle safety, immediately; or
where otherwise, upon completion of the works associated with the development.
Any repair work which proposes to alter the alignment or level of existing services and assets must first be referred to the relevant service authority for approval.
reasons for inclusion of conditions
The proposal is subject to specific built form parameters outlined in The Noosa Plan2006.
Advisory notes
The following notes are included for guidance and information purposes only and do not form part of the referral agency conditions:
Qualified Person
For the purpose of preparing a Geotechnical Report, and for certifying geotechnical stability for the development, a qualified person is considered to be a person who:
is a Registered Professional Engineer of Queensland (RPEQ); and
has a degree in civil engineering or engineering geology; and
has a minimum of 5 years experience in the field of geotechnical engineering or engineering geology.
Construction Management
The proposed development (demolition, excavation, deliveries, staff parking etc) has the potential to impact on the local area. If the construction of the proposed development requires occupation of the road reserve (verge area and/or road formation) for either short term or long term, a road reserve permit must be obtained from Council prior to any occupation of the road reserve. Please note any damage to the existing road reserve
Infrastructure Charges
All developments and/or changes to existing developments may require payment of “Infrastructure Charges” (as applicable) in accordance with Council’s “Charges Resolution” made pursuant to the planning legislation and regulations current at the time of issue.
rEPRESENTATIONS ABOUT REFERRAL AGENCY RESPONSE
The applicant may make representations to Council about this referral agency response at any time before the application is decided pursuant to section 30 of the Development Assessment Rules.

Yours faithfully,

Patrick Murphy
Coordinator Planning

Enc:	Approved Plans/Documents

[word/footer2.xml]
Page 4 of 5

[word/footer3.xml]
PO Box 141		P. (07) 5329 6500	[email protected]	
	TEWANTIN  QLD  4565	F. (07) 5329 6501	www.noosa.qld.gov.au
				Page 1 of 5

[word/header1.xml]
3

Used in these records

About this file

File size
83 KB (small file)
File type
DOCX

No other editions are linked here.

Original file

Log in to download the original file

Referral Agency Response - Planning RAP20 0036.docx · 83 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.