Log in to see the plans as drawnPOOL SAFETY
POOL SAFETY BARRIERS TO BE PROVIDED IN ACCORDANCE WITH QUEENSLAND DEVELOPMENT CODE MP3.4, AS1926.1 & 2 AND THE BUILDING ACT
(CHAPTER 8). RESUSCITATION SIGNS MUST BE MOUNTED IN PROMINENT POSITIONS.
WARNING SIGN PROVIDED TO SERVE THE PROPERTY PRIOR TO CONSTRUCTION OF THE POOL OR SPA IN ACCORDANCE WITH SECTION 233 OF THE
BUILDING ACT 1975. THE WARNING SIGN MUST BE DISPLAYED UNTIL A BUILDING CERTIFIER HAS PROVIDED A CERTIFICATE IN THE APPROVED
FORM STATING THE POOL IS A COMPLYING POOL.
PRIOR TO FILLING THE POOL TO A DEPTH EXCEEDING 300MM THE BUILDING CERTIFIER MUST INSPECT AND PROVIDE CONFIRMATION (FORM 17)
THAT THE POOL SAFETY BARRIERS ARE IN ACCORDANCE WITH THE BUILDING ACT
4 3 5 6
C60.0
1
C7.1
° 4800
1
120
61°
C60.0 LVL 1 POOL
55.59 m³
2556
2083
°
120
59°
250
*SE
2200
DECK OVER 25
0
1491 14886
*S 1194
E SPILLWAY WATER
FEATURE 1200w
POOL PLAN - LEVEL 1
SCALE: 1 : 50
3000
DECK OVER - REFER TO
FINISHES SCHEDULE 3140
940
ACCESS HATCH OVER
1LEVEL1
WL 2600 2700
2600
LVL 1 POOL
55.59 m³
BT POOL 3
2.20 m³
2000l MIN
1100
GATEHOUSE
ENTRY
1800 APPROX
POOL SECTION - LEVEL 1 OVERSPILL SECTION
SCALE: 1 : 10
SCALE: 1 : 20
CLIENT: Hunter Hopkins PROJECT: INFINITY
www.chriscloutdesign.com.au GENERAL NOTES:
Use written dimensions only. DO NOT scale drawings. Contractors SITE ADDRESS: Lot1-RP66483 & Lot1-RP70165,217-219 Gympie Terrace, Noosaville 4567
PO BOX 135, NOOSAVILLE, QLD 4566 to verify all dimensions on site prior to commencing works. Site
E: [email protected] location in accordance with engineers details. These drawings are to DRAWING TITLE: POOL DETAILS - LEVEL 1 (GROUND)
P: (07) 54748 107 be read in conjunction with engineers design and details, the
accompanying building specification and schedule of finishes. If in DATE: 07/08/19 SCALE:As indicated
@ A2 DRAWN BY: DWL
F: (07) 54748 108 BSA LICENCE: 1127508
doubt, please request clarification. DO NOT ASSUME. ISSUE: MINOR CHANGE AMENDMENT SET