Log in to see the plans as drawn GENERAL NOTES:
SHEET ISSUE
DRAWINGS TO BE READ IN CONJUNCTION WITH OTHER CONSULTANTS DOCUMENTATION.
REFER ANY DISCREPANCIES TO DESIGNER FOR WRITTEN DIRECTION.
SHEET NUMBER REV SHEET NAME STATUS REV ID
C2.0 F BASEMENT MINOR CHANGE AMENDMENT SET PLANNING UPDATES WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH RELEVANT CURRENT. SAA
CODES AND STATUTORY AUTHORITIES REQUIREMENTS.
C3.1 F LEVEL 1 MINOR CHANGE AMENDMENT SET PLANNING UPDATES
C3.2 D LEVEL 2 MINOR CHANGE AMENDMENT SET PLANNING UPDATES ALL DIMENSIONS AND LEVELS TO BE VERIFIED ON SITE BY BUILDER.
REFER ANY DISCREPANCIES TO DESIGNER FOR WRITTEN DIRECTION.
C6.0 F ELEVATIONS MINOR CHANGE AMENDMENT SET PLANNING UPDATES
C6.1 F ELEVATIONS MINOR CHANGE AMENDMENT SET PLANNING UPDATES FIGURED DIMENSIONS TO BE USED DO NOT SCALE DIMENSIONS.
C7.0 F BUILDING SECTION - TERRACE MINOR CHANGE AMENDMENT SET PLANNING UPDATES ALL STRUCTURAL ELEMENTS TO BE IN ACCORDANCE WITH ENGINEERS DESIGN AND
C7.1 E BUILDING SECTION - DINING & POOL MINOR CHANGE AMENDMENT SET PLANNING UPDATES DETAILS.
C60.0 F POOL DETAILS - LEVEL 1 (GROUND) MINOR CHANGE AMENDMENT SET PLANNING UPDATES ALL SERVICES INCLUDING FIRE FIGHTING SERVICES, OCCUPANT WARNING SYSTEMS,
C71.1 B STAIR DETAILS (FIRE ESCAPE) MINOR CHANGE AMENDMENT SET PLANNING UPDATES LIGHTING, POWER, WATER SUPPLY, SANITARY DRAINAGE, STORMWATER, MECHANICAL
VENTILATION AND AIR CONDITIONING TO BE IN ACCORDANCE WITH RELEVANT
C71.2 A STAIR DETAILS PERSPECTIVE MINOR CHANGE AMENDMENT SET PLANNING UPDATES CONSULTANTS DETAILS.
C73.0 A PUMP HOUSE MINOR CHANGE AMENDMENT SET PLANNING UPDATES
BUILDER TO VERIFY LOCATION OF EXISTING SERVICES AND PROPERTY BOUNDARIES PRIOR
TO COMMENCEMENT OF WORKS.
ALL EXTERNAL MATERIALS AND FINISHES TO BE IN ACCORDANCE WITH THESE DOCUMENTS
AND WRITTEN SCHEDULE OF FITTINGS AND FINISHES.
ALL INTERNAL FITOUT SELECTIONS TO BE IN ACCORDANCE WITH THESE DOCUMENTS AND
WRITTEN SCHEDULE OF FITTINGS AND FINISHES.
REFER ANY DISCREPANCIES TO DESIGNER FOR WRITTEN DIRECTION.
FLOOR LEVELS ARE INDICATIVE ONLY AND ARE TO CONFIRMED WITH SURVEYOR FOR
APPROPRIATE POSITION TO MINIMISE CUT & FILL
CLIENT: Hunter Hopkins PROJECT: INFINITY
www.chriscloutdesign.com.au GENERAL NOTES:
Use written dimensions only. DO NOT scale drawings. Contractors SITE ADDRESS: Lot1-RP66483 & Lot1-RP70165,217-219 Gympie Terrace, Noosaville 4567
PO BOX 135, NOOSAVILLE, QLD 4566 to verify all dimensions on site prior to commencing works. Site
E: [email protected] location in accordance with engineers details. These drawings are to DRAWING TITLE: SHEET LIST
P: (07) 54748 107 be read in conjunction with engineers design and details, the
accompanying building specification and schedule of finishes. If in DATE: 07/08/19 SCALE: 1 : 100 @ A2 DRAWN BY: C.CLOUT
F: (07) 54748 108 BSA LICENCE: 1127508
doubt, please request clarification. DO NOT ASSUME. ISSUE: PRELIMINARY TENDER ISSUE
C0.1 [E]