Council archive · source document
Response to Information Request [As Published] · 132008.107
1 2 3 4 5
1,500 4,500 5,000 1,000 4,000 1,000 3,000 3,000
1,000 3,500 1,000 3,000 1,000 3,000 1,000
1,973
Fixed glass gable infill Gable infill wall
Selected Spitters rh
6 5 rh
90
A A
1,000
Fixed glass louvre celestory windows
Celestory windows m in high wall
100
in high wall
fall
fall
Metal awning to future detail
B B
4,500
fall
Box gutter behind
3,305
deep fascia Selected Spitters Box gutter behind
deep fascia
Polycarbonate
4,500
sheeting with
m dp battens under.
10 deg. FALL (Batten direction D
3,000
100
shown) no gutter.
B B
3,000
fall
Fixed P/coated Alumin. batten Rainhead Fixed glass gable infill
rh
spit spit
2,905
frame insert within cantilevered
C roof framing C C
1,000
Fixed glass celestory
23.5 deg. FALL
windows with mitred corners
in high wall. see elevation
m
m
90
fall
fall
fall
10 deg. FALL
10 deg. FALL
5,000
3,000
A A
2,860
23.5 deg. FALL
W5 W6
fall
fall
fall
over over
m
dp
1,000
90
11
10
12
9
8
7
6
5
4
3
2
1
E E rh
D D
13
14 dwn
spit spit
bulkhead at 2100H
Rainhead Fixed P/coated Alumin. batten
W7
W4 frame insert within cantilevered
3,500
over RL 18.400 roof framing
11 44 Box Gutter with deep Fixed glass
fall
4,500
STUDIO SW fascia & rainheads D gable infill wall
fall
selected to each side.
Kliplock or equal roof timber floor Celestory windows
6,500
at 5 deg. fall. Box Gutter with deep in high wall
fall
fascia & outlet spitters
W3 W2 to each side. Box gutter behind
over over deep fascia
fall
louvre celestory windows rh
in high wall Gable infill wall
fall
rh Metal awning to future detail
E E
300
Rainhead & D.P
C Box Gutter behind parapet wall
& rainhead at box gutter outlet
6 5
LEGEND :
SW sliding window
dp down pipe
1 2 3 4 5
NOTES :
PROPOSED UPPER FLOOR & ROOF PLAN
Where notes refer to 'selected' please refer to Architects Specification
Where notes refer to 'future detail' please refer to Architects Specification
unless location indicated otherwise.
SCALE 1 : 100
All work to coply with Building Code of Australia and its most current
0 5m amendments, this construction being of class 1.
Before commencing construction, all dimensions, existing levels,
finished levels & site services are to be verified are to be verified.
Architectural drawings are to be read in conjunction with any
associated consultants drawings.
NOTES AMENDMENTS COPYRIGHT THESE DRAWINGS DRAWING
DRAFTING CLIENT PROJECT
RL's added
TO BE USED ONLY WITH ROBINSON Architects REVISED BA / TENDER ISSUE
MR & MRS C & L BROWN PROPOSED RESIDENCE AT
ARCHITECTS WRITTEN CONSENT Kenneth Robinson B.Arch A.R.A.I.A. 127 DUKE RD DOONAN QLD 4562
Grid lines added to elevations & sections Reg No. 001991
P.O BOX 866 DRAWN RP
DO NOT SCALE OFF DRAWINGS Jolyon Robinson B.Arch B.B.E NOOSA HEADS QLD 4567 DESIGN to DETAIL
LOT 10 TRISTANIA DRIVE
Ground line at garage wall amended Reg No. 003589
DATE 080208
REFER ANY DISCREPANCIES TO Alexander Robinson Dip Arch. Tech. Ph. (07) 54710455 ROBERT PATTERSON
MARCUS BEACH, QLD, AUSTRALIA.
Building Design Lic No. 1057760 QBSA Lic.No. 1095554
ARCHITECT Fax. (07) 54710780
fax : (07) 5449 1899
SCALE AS SHOWN
VERIFY ALL DIMENSIONS ON SITE Email. [email protected] m : 0401 394 964
NO. 05
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records