E D C B A
A B C D E
High mount windows s/steel 1/2 round gutter
Selected wall cladding over timber
framed walls to eng'r design
Tapered rafter tails Alumin. awning over window
boundary
Frameless glass Pivot entry door
with frameless side glass Fixed P/coated Alumin. Batten insert to
cantilevered roof over deck as spec.
Louvred roof over entry deck Corner glass Garage parapet wall beyond
mitred join, no mullion with box gutter & flat roof behind. High mount windows
Tapered rafter tails
300
High mount windows
Selected wall cladding selected cladding
Corner glass
bulkhead ( spandeck) over timber bulkhead
Roofline beyond mitred join, no mullion
framed walls to eng'r design hidden gutter behind parapet
2,100
2,100
Reinforced Concrete block
Corner glass parapet wall with w/proof texture
mitred join, no mullion coat render finish & zinc capping UPPER FLOOR
FL 18.400 to box gutter & flat roof behind. FL 18.400
3.5m Average Height gutter spitter to future detail
300
300
boundary
2,700
Selected wall cladding Selected panellift garage door
selected louvre shutter window
2,400
2,400
'spandeck finish'
frameless glass H/rail
FL 15.700 FL 15.700 at 1000H to future detail
GROUND FLOOR
boundary
steel beam with tapered
natural ground line ends to eng'r design
fixed glass window selected p/c Alumin framed
boundary
3,000
to garage windows & doors
Reinforced concrete block wall base Selected wall cladding over timber
with selected w/proof render finish framed walls to eng'r design
boundary
LOWER FLOOR Reinforced concrete block wall base
FL 12.700 with selected w/proof render finish
WESTERN ELEVATION
800
HWD batten infill between
11.900
floor & ground
SCALE 1 : 100
Reinforced concrete block wall base HWD stair
selected bifold doors core filled block wall
A B C D E with selected w/proof render finish gal. steel stringers
with render finish.
steel beam with tapered selected louvre steel beams with tapered ends
ends to eng'r design shutter window supported by steel columns
to eng'rs detail.
E D C B A
EASTERN ELEVATION
SCALE 1 : 100
A B C D E E D C B A
metal awning over window
selected cladding over
to future detail Frameless glass Pivot door
timber framed wall
selected p/coat alumin. & Fixed Glass side windows
parapet wall to front of garage framed stacking windows to entry beyond
23.5 deg roof pitch selected s/steel rainhead 15 deg. fall to roof
hidden gutters behind parapet polycarb roof over from box gutter behind Exposed HWD rafters with polycarb sheeting over.
1/2 round s/steel gutters
stained hwd battens reo conc block parapet wall stained HWD battens under, to future detail
exposed HWD truss tails cavity sliding doors
to future detail. to partition wall remote operated glass bulkhead bifold panellift windows
louvre windows installed to manufac. spec. metal awning over window
to future detail
2,100
hidden gutter
FL 18.400 FL 18.400
gutter spitter to future detail
300
selected bifold
300
tapered exposed HWD rafter tails panellift windows
BREEZE-WAY selected p/coat alumin.
2,700
installed to manufac.
BREEZE-WAY framed windows
2,400
frameless glass H/rail spec.
/ FOYER
2,400
/ FOYER at 1000H to future detail
frameless glass
balustrade to 1000 H
FL 15.700 FL 15.700
Steel beam with tapered ends w/proof texture coat finish to reinforced
frameless glass H/rail to eng'r design block retaining walls under suspended
3,000
at 1000H to future detail window floor framing.
around corner Suspended timber
framed floor
boundary
boundary
ea. side w/proof texture coat finish to reinforced
steel beams supporting block retaining walls under suspended
FL 12.700 timber framed floor to eng'r design. floor framing.
800
SECTION / ELEVATION 6
11.900 no gutters for this roof.
SCALE 1 : 100 taper rafter tails
boundary
boundary
Steel beams supporting
A B timber floor C
Steel beams under
D E E D C B A
SECTION / ELEVATION 5
SCALE 1 : 100
NOTES AMENDMENTS COPYRIGHT THESE DRAWINGS DRAWING
DRAFTING CLIENT PROJECT
RL's added
TO BE USED ONLY WITH ROBINSON Architects REVISED BA / TENDER ISSUE
MR & MRS C & L BROWN PROPOSED RESIDENCE AT
ARCHITECTS WRITTEN CONSENT Kenneth Robinson B.Arch A.R.A.I.A. 127 DUKE RD DOONAN QLD 4562
Grid lines added to elevations & sections Reg No. 001991
P.O BOX 866 DRAWN RP
DO NOT SCALE OFF DRAWINGS Jolyon Robinson B.Arch B.B.E NOOSA HEADS QLD 4567 DESIGN to DETAIL
LOT 10 TRISTANIA DRIVE
Ground line at garage wall amended Reg No. 003589
DATE 080208
REFER ANY DISCREPANCIES TO Alexander Robinson Dip Arch. Tech. Ph. (07) 54710455 ROBERT PATTERSON
MARCUS BEACH, QLD, AUSTRALIA.
Building Design Lic No. 1057760 QBSA Lic.No. 1095554
ARCHITECT Fax. (07) 54710780
fax : (07) 5449 1899
SCALE AS SHOWN
VERIFY ALL DIMENSIONS ON SITE Email. [email protected] m : 0401 394 964
NO. 07
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Response to Information Request [As Published]Related documentApplication case desk ↗
About this file
- File size
- 3.8 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.