4.0 Planning Report

Attached to the e-mail Industrial Business Type 2, 3 x Ancillary Dwelling Units & Op Works - MCU18/0062 & OPW18/0084.

of 38

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

12 March 2018




The Chief Executive Officer
Noosa Council
PO Box 141
Tewantin QLD 4565
Via email: [email protected]



RE: DEVELOPMENT APPLICATION (CODE ASSESSMENT) FOR MATERIAL
CHANGE OF USE & OPERATIONAL WORKS TO ESTABLISH INDUSTRIAL
BUSINESS – TYPE 2 & ANICLLARY DWELLING UNIT (3).

Fee calculation:

The proposed development onsite is defined as Industrial Business Type 2 and Ancillary
Dwelling Unit with a combined use area of 1342.5 sq.m

MCU applicable Industrial Business Type 2 fee……………………………$6,574.00

MCU applicable Ancillary Dwelling Unit fee………………………………$2,162.00

OPW applicable fee (1,401–5,000 sq.m)…………………………………....$5,143.00




ADDRESS: 6 Vision Court, Noosaville 4556
LOT: 7 SP295958
AREA: 1864.84 sq.m
PLANNING SCHEME: The Noosa Plan 2006
PLANNING AREA: Noosaville locality
ZONE: Industry




                                                               Building Suncoast Green   1
Log in to download the original file

4.0 Planning Report.pdf · 2.4 MB (large file)

The download may take up to a minute.

Full text of the other 37 pages

Page 2

Considerations.
This report has been prepared subject to a Material Change of Use and Operational Works application
for a proposed development to accommodate the business and use of our client. Aspects of this
application are general in structure but details are specific to our client’s needs.



REPORT DETAILS

 Report Prepared by:                                Will Johnson (Building Suncoast Green)

 Report Authorised by:                              Debbie Johnson (Building Suncoast Green)

 Report Prepared for:                               Paul Winter acting on behalf of all owners as per
                                                    the current registered title (attached)
 Distribution:                                      Noosa Shire Council
                                                    Unitywater
 Land Ownership:                                    PETER BARRY BREWER &
                                                    HELEN ANNE BREWER TRUSTEE 3/20
                                                    UNDER INSTRUMENT 718542717

                                                    MARTIN EDWARD GREEN &
                                                    JANETTE ANN GREEN TRUSTEE 3/20
                                                    UNDER INSTRUMENT 718542717

                                                    PAUL TIMOTHY WINTER &
                                                    ELIZABETH MARY WINTER TRUSTEE 2/5
                                                    UNDER INSTRUMENT 718542717

                                                    SUNRISE SLIPSTREAM PTY LTD A.C.N. 622
                                                    325 482
                                                    TRUSTEE 3/10
                                                    UNDER INSTRUMENT 718542717


The following attachments support this application;

       Building Design Plans ISSUE I, Project No 2017-43 (Part 1 &2) prepared by Building
        Suncoast Green
       Civil Design Plans Drawing No. 27287 prepared by SCG Engineers.
       Detail Survey ISSUE A, Drawing No 12482-DTM-01 prepared by Land Surveying Dynamics
       Land owners consent & Registered title
       DA form 1




                                                                                Building Suncoast Green   2

Page 3

Contents
       Considerations................................................................................................................................. 2
1.0 Introduction ...................................................................................................................................... 4
   1.1 Proposal ........................................................................................................................................ 4
   1.1 Site Summary ................................................................................................................................ 5
   1.2 Development Synopsis .................................................................................................................. 5
2.0 Site Context ....................................................................................................................................... 6
   2.1 Site location .................................................................................................................................. 6
3.0 State Planning Consideration ............................................................................................................ 8
4.0 State Planning Policy Consideration ................................................................................................. 8
5.0 Level of assessment .......................................................................................................................... 9
6.0 Local planning consideration .......................................................................................................... 10
   6.1 Land Use Definition ..................................................................................................................... 10
   6.2 Locality and Zone ........................................................................................................................ 11
7.0 Applicable codes and overlays ........................................................................................................ 12
   7.1 Biodiversity Overlay Code ........................................................................................................... 14
   7.2 Caretaker’s Unit – (Ancillary Dwelling Unit) ............................................................................... 14
   7.3 Earthworks Code ......................................................................................................................... 14
   7.4 Erosion and Sediment Control Code ........................................................................................... 14
   7.5 Existing Services Code ................................................................................................................. 15
   7.6 Transport, Roads and Drainage Code ......................................................................................... 15
   7.7 Waste Management Code .......................................................................................................... 15
   7.8 Water Sensitive Design Code ...................................................................................................... 15
8.0 Conclusion ....................................................................................................................................... 15
Appendix 1. ........................................................................................................................................... 16




                                                                                                                 Building Suncoast Green                     3

Page 4

1.0 Introduction

Dear Sir/Madam
This report has been prepared subject to a development application for a combined material
change of use and associated operational works to develop vacant land in accordance with the
regulatory provisions of the Noosa Plan.

We as the applicants have been engaged by our client, Paul Winter whom is acting on behalf
of all land owners as outline on the attached registered title.

1.1 Proposal


Development is proposed, comprising seven individual tenancies within one building. The building is
of a tilt-slab concrete construction, with each tenancy divided by a tilt-panel fire insulated wall. Each
tenancy has been designed to be of similar size (being 123.4-125.0sq.m respectively excluding
mezzanines) and shape, with the exception of tenancy 1 which has been configured due to the site
constraints. Three tenancies have proposed caretaker’s residences, these are located in buildings 7, 6
and 5 and are positioned towards the rear of the site. All buildings have been designed and orientated
towards the east, ensuring afternoon heat and glare from the west is absorbed into the rear tilt-panel
concrete wall. Eaves are incorporated into the building design and are an essential element of the built
form.

Car parking has been proposed on the eastern boundary and is separated from the property boundary
by 1.15M (approximately). This area is proposed as landscaping. Additional landscaping has been
provided at the front of the site between Vision Crt and the proposed building, and at the rear of the
site between the rear property boundaries and the building. Landscape species selected are endemic to
the Noosa shire and the design achieves bulk, scale and clumping so as to mitigate the visual scale and
bulk of the built structure.




                                                                             Building Suncoast Green        4

Page 5

1.1 Site Summary
Site Address:                   6 Vision Court, NOOSAVILLE
Lot/Plan:                       Lot 7 SP295958
Area:                           1864.84 sq.m
Existing Use:                   Vacant Industrial Land
Local Government Area:          Noosa Shire
Planning Locality:              Noosaville, QLD
Zone:                           Industrial
Overlays:                       Biodiversity
                                Natural Hazards


1.2 Development Synopsis
GFA                             1100.0sq.m – Industrial Business Type 2
                                242.5sq.m – Ancillary Dwelling Unit (total)
                                - Dwelling Unit 7 78.8sq.m
                                - Dwelling Unit 6 78.8sq.m
                                - Dwelling Unit 5 84.9sq.m
                                Total GFA – 1342.5sq.m
Landscaping                     15% required – 15% provided (280.6sq.m)
Building Height                 7.142M (approx.) Height
Building Setbacks               - 6.5M Front boundary where parallel
                                - 4.5M Front Boundary where not parallel
                                - 3.0M Rear boundary
                                - 0.0M Side boundary (west)
                                - 12.95M Side boundary (east)
Car Parking                     17 car parks and 3 motorcycle parks have
                                been provided.
                                SRV loading bay provided on site.
Access and Servicing            One primary street access from Vision
                                Court – 6.0M wide.
Refuse Storage and Collection   On site storage and collection of refuse
                                located within the property boundary in an
                                unobtrusive location.




                                                        Building Suncoast Green   5

Page 6

2.0 Site Context

        2.1 Site location
The site is part of the Noosa Industrial Park which is centrally located amongst the
established industrial precinct of Noosaville (see figure 1). Situated 7 minutes’ drive from
Hastings Street and less than 1 Kilometre from Noosa’s Shire business centre and shopping
centre.


Noosa Eumundi Road acts as a major feeder road in and out of the Noosa region from the
Bruce Highway and is the main spine road through the Noosaville industrial precinct.
Noosaville Industrial Park offers access to Eumundi Road from both Venture Drive and
Gateway Drive and will link road the two precincts together improving traffic flow and the
volume of passing traffic through the area.


Venture Drive, to the east is a mix of existing industrial developments, comprising of local
businesses. Gateway Drive to the south-east is also a mix of industrial developments,
accommodating a diverse mix of local businesses – excluding the newly developed Bunnings
Warehouse. The subject site is one of many newly created lots that now link the two
industrial precincts together.
Figure 2 indicates zoning.

The existing vacant site subject of this application forms as a second stage to the newly
created lots fronting Venture Drive. Development has been recently completed on several lots
on Venture Drive, with future development planned to begin in the near future also. The site
is clear of any mature vegetation as a result of operational works and the creation of lots. The
proposed development on site includes a mix of deep rooted and soft planted landscaping,
totalling 15.0% of the sites area, and will result in the provision of endemic species and shade
trees to soften the built form and visual appearance of the street.




                                                                       Building Suncoast Green     6

Page 7

Figure 1.




Figure 2.




            Building Suncoast Green   7


[OCR of page images]
 

 

Building Suncoast Green

Page 8

3.0 State Planning Consideration

The proposed development is located within the Urban Footprint of the South East
Queensland Regional Plan.

Urban Footprint Intent;

       The Urban Footprint identifies land that can meet the region’s urban development
needs to 2031 in a more compact form (SEQRP, 2017).

Description;

       The Urban Footprint includes established urban areas, broad hectare and remnant
broad hectare areas that could be suitable for future urban development. It incorporates the
full range of urban uses, including housing, industry, business, infrastructure, community
facilities and urban open space (SEQRP, 2017).

Further to this Local Government planning schemes are the main instrument to which will
refine the desired use of the land and the preferred timing of development within the Urban
Footprint.

       Comment; Upon consideration of this proposed development against the provisions of
the Noosa Planning Scheme and the relevant parts of the South East Queensland Regional
Plan, the proposed development is consistent with the overall intent for the land and area of
which it is proposed.

4.0 State Planning Policy Consideration


The proposed development was considered against the criteria of the State Planning Policy
(SPP), Part E – Assessment Benchmarks. It was identified that the subject application does
not require assessment against assessment benchmarks within Part E of the Policy, as matters
associated with the climate condition storm tides and flooding have been dealt with via the
local planning instrument and the statements atop of this page (State Planning Consideration).




                                                                      Building Suncoast Green    8

Page 9

5.0 Level of assessment

5.1 Synopsis

 Description of Use                               Industrial Business Type 2
                                                  Ancillary Dwelling Unit
 Approval Being Sought                            Material Change of Use & Operational
                                                  Works
 Level of Assessment                              Code Assessment.


 Referral Agencies                                None applicable.




Chapter 3, Part 1 of the Planning Act 2016 (PA), stipulates Types of Development and
Assessment. Section 44 of the PA lists the categories of development as follows;

(1) There are 3 categories of development, namely prohibited, assessable or accepted
development.

(2) Prohibited development is development for which a development application may not be
made.

(3) Assessable development is development for which a development approval is required.

(4) Accepted development is development for which a development approval is not required.

Section 45, point (1) of the PA then refers categories of assessment as Code and Impact when
development is Assessable.

Section 45, point (2) of the PA then gives authority of a categorizing instrument to determine
the categories of assessment that must be carried out for the development.

For this application, the relative categorizing instrument is that of which is prescribed by the
Noosa Plan; Division 11 – Table 11.9 (Assessment Table for the Industry Zone)




This application seeks approval for a material change of use of vacant industrial land to be
developed and accommodate Industrial Business Type 2 activity and three Ancillary Dwelling



                                                                        Building Suncoast Green    9

Page 10

Units. Approval is also sought for operational works which involves earthworks, vehicle
parking, access way, hardstand pedestrian infrastructure, landscaping and connection to
reticulated water, sewerage and underground electricity.


The Planning Act 2016 defines this work as assessable development, and is deemed a code
assessment application under the provisions of Division 11 – Table 11.9 (Assessment Table
for the Industry Zone)


The operational works component of this application is code assessment, being work
consistent with the industrial business activity.


The development does not require referral to any external referral agencies.

6.0 Local planning consideration

       6.1 Land Use Definition
The proposed development at the above mentioned address, has been defined by the Noosa
Plan as;

Primary Use – Business

Use Class – Industrial Business; means the conduct of an industrial business activity, where
goods or products are produced, manufactured, dismantled, altered, repackaged, repaired or
stored at a scale of greater than that defined by retail business. The use includes the sale of
goods, resulting from such operations, provided that sales space does not exceed 20% of the
use area. Any space dedicated for administration or accounting work in connection with such
operations does not exceed 20% of the use area. The term includes the following types


Use – Type 2 Production, alteration, repackaging & repairing.
The use of premises for the production, manufacturing, dismantling, altering, cleaning, re-
packaging, freezing or repairing of goods. The use includes food industries, textiles,
mechanical, boat repair, sandblasting


Primary Use – Residential


Use – Ancillary Dwelling Unit.



                                                                        Building Suncoast Green   10

Page 11

Ancillary dwelling unit means the use of premises for a caretaker’s residence or employee
residence associated with a non-residential use on the same premises where:

   •   There is no other dwelling unit on the premises, except where the non-residential use
       is an agricultural use;
   •   The gross floor area of the dwelling unit does not exceed 150m2;
   •   The dwelling unit is subordinate to the non-residential use;
   •   The dwelling unit is attached to or within 25m of the non-residential use; and
   •   The dwelling unit is occupied by the owner of the non-residential use or somebody
       employed in the non-residential use.


       6.2 Locality and Zone
The subject development is located in the Noosaville locality – Map area 8, within the
industry zone of the Noosa Council.

       The overall outcomes sought for the Noosaville Locality are the following—

       a) New uses and works are located, designed and managed to—

              1. be compatible with other uses and works;
              2. maintain the safety of people and works;
              3. avoid significant adverse impacts on the amenity enjoyed by users of other
                  premises, including acoustic and visual qualities; and
              4. avoid significant adverse effects on the natural environment, including
                  native habitat removal, fragmentation and attrition;

       b) Development is consistent with the Priority Infrastructure Plan in Part 15.

The proposed development is recognised as a consistent use and is compatible with and
complimentary to the mix of industrial business uses within the surrounding area.


All development works and business operations will be carried out according to work health
and safety requirements. The proposed development includes landscaping for visual
screening and potential acoustic impacts will be managed to a level that is acceptable within
an Industrial area.


The subject site is currently vacant as it has been cleared for the development and
reconfiguring of new lots creating further available lots in the industrial park.



                                                                         Building Suncoast Green   11

Page 12

7.0 Applicable codes and overlays

The following Codes and Overlays have been identified as needed assessment against the
proposed development.
      Noosaville Locality Code; (refer section 8.2.1 – 8.2.3)
      Business Uses Code;
      Landscaping Code;
      Biodiversity Overlay Code;
      Ancillary Dwelling Unit – (Caretakers Unit)
      Natural Hazards Overlay Code;
      Engineering Works Codes;
       o Driveways and Car parking Code;
       o Earthworks Code;
       o Erosion and Sediment Control Code;
       o Existing Services Code;
       o Transport, Roads and Drainage Code;
       o Waste Management Code;
       o Water Sensitive Design Code;


Comment: An assessment of the Business Use Code, Landscaping Code and Driveways and
Car parking Code has been completed and included in Appendix 1.


This code assessment has determined that the proposal generally complies with all probable
solutions and specific outcomes. The proposal has been determined not to comply with the
probable solutions with respect to bicycle parking and car parking. Further, the proposal has
also failed to comply entirely with the Building Works code with respect to building setbacks
as specified in schedule 1. We believe the proposal does comply with the Specific Outcomes
of the relevant codes, and has been discussed below accordingly.


The proposed development does not comply with Probable Solution 31.2 of the Business
Uses code (Bicycle Parking). As per Figure 14.1, 1 bicycle space per 100sq.m GFA is require
for Industrial Business Type 2 activity. The proposal has provided 1 bicycle space per
tenancy equating to a total of 7 spaces. We believe this generally still complies with the
intentions of the planning scheme, ensuring development promotes alternative means of



                                                                       Building Suncoast Green   12

Page 13

transport other than a motor vehicle. Further, given the small nature of the proposed tenancies
being approximately 180 sq.m (including mezzanines) and the anticipated low staff and or
visitor numbers based on intended use, we believe further bicycle parking is not warranted
and should be reconsidered in this context.


The proposed development does not comply with Probable Solution 7.1 of the Driveways and
Parking code (Table 14-51 Vehicle Parking Requirements). The proposal has provided a total
of 20 car parks and 3 motorcycle parks. Table 14-51 determines the industrial activity GFA
attracts 18 car spaces with an additional 3 spaces required for the caretakers residences
(Ancillary dwelling unit). To achieve compliance with Noosa Councils Motorcycle and
Scooter Parking Policy the proposal replaced a vehicle car park for 3 motorcycle spaces. As a
result the total number of parking is 1 short of the planning schemes requirement.


We believe the proposed development complies the Specific Outcome (7) of the Driveways
and Parking code as sufficient parking (all vehicle types) are provided for onsite based on the
intended activity and intensity of the use. At this time the exact business types are unknown,
however due to the small nature of the proposed tenancies, it is not anticipated that being 1
car space short will have negatively impact on surrounding business nor future on-site
businesses.


The proposed development does not comply with the Probable Solution 1.1 of the Building
Works code – Schedule 1, Minimum Boundary Setbacks. The subject sites front boundary is
not parallel to the rear boundary. As such has resulted in parts of the building fronting the
street having a setback of less than 6.0M. The specific dimensions of the conflict can be seen
on the attached Building Design Plans by Building Suncoast Green. In summary the building
is setback from the street 6.5M and an average of 4.5M. However, the building has been
designed to mitigate the visual impacts of this encroachment via stepping the building. The
building also includes 600mm eaves overhang which reduces the visual bulk of the
encroachment. We believe the proposal complies and achieves the specific outcomes of this
code.




                                                                        Building Suncoast Green   13

Page 14

The remainder of the Codes identified in section 7.0 above in Italics have been addressed
below fittingly.


       7.1 Biodiversity Overlay Code
The proposed development is identified as being in the Environmental Protection Area. The
subject site is located within the industrial zone on land that has been cleared and prepared
for future development purposes. Currently the site does not contain any natural and
regulated vegetation or regional ecosystems. At most, vegetation on the site is sections of re-
growth and small to medium sized groupings of grass species. The proposed development
will include landscaped sections facing the street totalling 269.2sqm which will include
preferred endemic species suited to the area, (refer to attached landscape plans for details).
This is meets the required landscape requirements as specified in the relevant sections of the
Planning Scheme.


As a result vegetation and biodiversity of the site will be improved, as will surrounding sites
with future development anticipated. Erosion and sediment control measures will be
implemented during construction and appropriate drainage networks will be put in place to
ensure minimal impact on the surrounding waterways from runoff from the site.


       7.2 Caretaker’s Unit – (Ancillary Dwelling Unit)
The proposed development includes three ancillary dwelling units in three separate premises.
This is a consistent use within the Industrial Business Area of which this development is
proposed. In consideration of the definition of the Ancillary Dwelling Unity (Caretaker’s
Unit) it was found that the proposal was compliant with the parameters of the definition, and
that the proposed Units are ancillary to the industrial activity. Please see attached Building
Design Concept Drawings reflecting this statement


       7.3 Earthworks Code
The proposed development achieves the specific outcomes of the Earth Works Code as
detailed in the attached Engineering Drawings.

       7.4 Erosion and Sediment Control Code
The proposed development achieves the specific outcomes of the Erosion and Sediment
Control Code as detailed in the attached Engineering Drawings.




                                                                        Building Suncoast Green   14

Page 15

        7.5 Existing Services Code
 The proposed development achieves the specific outcomes of the Existing Services Code as
 detailed in the attached Engineering Drawings


        7.6 Transport, Roads and Drainage Code
 The proposed development achieves the specific outcomes of the Transport, Roads and
 Drainage Code as detailed in the attached Engineering Drawings. There is no existing
 pedestrian/cycle path infrastructure completed at present, however the proposed development
 has been designed to accommodate such infrastructure in this proposal. Refer to Empire
 Engineers civil drawings.


        7.7 Waste Management Code
 The proposed development achieves the specific outcomes of the Waste Management Code
 as contained within Table 14-60. Please refer to the attached Building Design Drawings
 prepared by us reflecting the detail, location, storage and waste management receptor as
 required within the applicable table


        7.8 Water Sensitive Design Code
 The proposed development achieves the specific outcome of the Water Sensitive Design
 Code as detailed in the attached Engineering Drawings.

8.0 Conclusion

In conclusion we find this development to be compliant with the overall outcomes of the
applicable codes and provisions of the Noosa Planning Scheme. If Council requires any further
assistance regarding this application please do not hesitate to contact our office.


Yours Sincerely




Debbie Johnson
[email protected]




                                                                      Building Suncoast Green   15

Page 16

Appendix 1.




              This page has been intentionally left blank




                                                            Building Suncoast Green   16


[OCR of page images]
Appendix 1.

This page has been intentionally left blank

 

Building Suncoast Green

Page 17

Division 26. Specific Outcomes and Probable Solutions for the Industry Zone


                      column 1                                          column 2
                  Specific Outcomes                                 Probable solutions
  11.51    Consistent uses
  O186 The following defined uses and use classes
  are consistent uses and are located in the Industry   Complies – The proposed
  Zone—                                                 development is for Industrial
                                                        Business Type 2 – Alterations,
  a)   Industrial business Types 1 or 2;                packaging, repairing & dispatch, and
  b)   Retail business Types 3, 5 or 6;                 three Ancillary Dwelling Units and is
                                                        a consistent use of the land
  c)   Retail business Type 4 if a vehicle sales
       premises and located with frontage to Lionel
       Donovan Drive;
  d)   Education Type 3 if trade related vocational
       training
  e)   Emergency Service Type 2;
  f)   Service and utility;
  g)   Transport Types 1, 2 or 3; and
  h)   Ancillary dwelling unit.
  11.52    Inconsistent uses
  O187 The following defined uses and use classes
  are inconsistent uses and are not located in the      N/A
  Industry Zone—

  a)   All Agricultural Uses;
  b)   Commercial business;
  c)   Entertainment and dining business;
  d)   Home-based business;
  e)   Industrial business Type 3
  f)   Retail business Types 1, 2 or 7;
  g)   Retail business Type 4 if not a vehicle sales
       premises located with frontage to Lionel
       Donovan Drive
  h)   Education if not Type 3 and trade related
       vocational training;
  i)   Emergency Service Type 1;
  j)   Open Space;
  k)   Wellbeing;
  l)   Transport Type 4;
  m)   Detached house;
  n)   Community residence;
  o)   Multiple housing; and
  p)   Visitor accommodation




                                                                          Building Suncoast Green   17

Page 18

               column 1                                              column 2
           Specific Outcomes                                     Probable solutions
11.53     Effects of use


Amenity                                      Complies – The proposed development is a
O188 Uses are predominantly of an            Industrial Business, Type 2 – Production,
industrial nature ordinarily expected in     alteration, repairing and packaging. The
an industrial estate with ancillary uses     ancillary dwelling units are intended to be
compatible with industrial businesses.       ancillary to the primary use being Industrial
                                             Business, Type 2.
O189 Industry business uses are
located, designed and operated to            Complies – The proposed industrial
avoid significantly changing the             development is situated central to other future
amenity enjoyed by users of                  and existing industrial business uses. The
surrounding premises.                        proposed development will include
                                             landscaping for visual screening, and noise
                                             will be consistent with what is expected for
                                             industrial business in the area, and will not
                                             adversely impact on the surrounding
                                             environment and amenity.




Storage of materials                         Complies – It is intended that the storage of
O190 Materials stored outside of             materials will be kept inside in allocated areas
buildings do not exceed half the height of   of the development, where materials will be
the on-site buildings; OR                    stored externally, appropriate screening will
O191 If there are no on-site buildings,      be constructed so as to not be seen from the
the stored materials do not exceed 5m;       street and adjoining properties.
AND
O192 Storage areas are screened from
the street and adjoining properties by
buildings, landscaping or fencing.




                                                                           Building Suncoast Green   18

Page 19

                                                                                .
Frontages                                    S193.1 A landscaped                N/A
O193 The frontage of each site contains      building setback of 10m is to
landscaping without adversely screening      be provided to Walter Hay
the business or visitor carparking;          Drive, Eumundi-Noosa               N/A
                                             Road and Eenie Creek
AND                                          Road, unless this is the only
                                             frontage to the site, in which     N/A - The proposed
                                             case it can be reduced to          development does not
                                             6m; AND                            front onto Walter Hay
                                                                                Drive,
                                             S193.2 This setback area           Eumundi-Noosa Road or
                                             is to include a minimum of         Eenie Creek Road.
O194 Vehicle display is focused on and       2m of soft landscaping
orientated towards Lionel Donovan Drive      behind which uncovered
rather than Walter Hay Drive, Eumundi-       visitor carparking may be
Noosa Road or Eenie Creek Drive;             located;
AND                                          AND
O195 Development fronting Walter Hay
Drive, Eumundi-Noosa Road and Eenie          S194.1 There is no display
Creek Road is sympathetic to the             of motor vehicle for sale or
character of the area and suitable for its   hire on Walter Hay Drive,
position along the entry roads to the        Eumundi-Noosa Road or
coastal urban part of Noosa.                 Eenie Creek Road frontages;
                                             AND

                                             S195.1 No direct vehicular
                                             access is taken off Eenie
                                             Creek Road or Walter Hay
                                             Drive where the property
                                             has access to any other
                                             road



Environmental Protection                     No solution provided.               Complies - The proposed
O196 Industrial development is                                                   development is located on
conducted in an environmentally                                                  land that has been
responsible manner, operating without                                            previously
deleterious impacts on immediate,                                                cleared and filled for
surrounding or downstream                                                        development purposes.
communities, environments and                                                    The proposed
environmental processes.                                                         development will be
                                                                                 conducted in an
                                                                                 environmentally
                                                                                 responsible
                                                                                 manner. Erosion and
                                                                                 sediment control
                                                                                 measures will be
                                                                                 implemented during
                                                                                 construction and
                                                                                 appropriate
                                                                                 drainage networks will be
                                                                                 put in place to ensure
                                                                                 minimal impact on the
                                                                                 surrounding waterways
                                                                                 from runoff from the site.




                                                                              Building Suncoast Green         19

Page 20

11.54    Built form

Visual amenity and character                 No solution provided   Complies – The proposed
O197 Buildings are designed and sited to                            development reflects
provide visual interest and amenity by—                             articulated facades so as
a)     providing well articulated                                   provide visual interest and
       buildings with strong horizontal                             amenity. The development
       and vertical design                                          will include strong
                                                                    horizontal and vertical
                                                                    design patterns in keeping
                                                                    with the overall character
                                                                    of the building. Please refer
                                                                    to attached Building Design
                                                                    Drawings for details.


elements and features;
b)   using a variety of external building
     materials within external walls where                          Complies – The proposed
     such walls are visible from the                                development reflects the use
     street; and                                                    of varying materials to create
c)   providing for interesting and                                  features and textures so as to
     varied site layouts and roof                                   vary the site layout and roof
     designs;                                                       design.

AND
O198 Buildings are designed to provide
for a range of potential users by allowing                          Complies – The proposed
for adaptable floor plans and adequate                              development has
floor to ceiling heights.                                           been designed with high
                                                                    ceiling spaces to allow future
                                                                    range of uses. The floor plans
                                                                    are wide and deep providing
                                                                    for opportunities at a future
                                                                    point in time for other uses.




                                                                    Building Suncoast Green          20

Page 21

BUSINESS USES CODE
14.12 Specific Outcomes and Probable Solutions for the Business Uses Code

           column 1 Specific Outcomes                                       column 2
                                                             Probable solutions (if code assessable)
14.16    Effects of use

Electricity infrastructure            S18.1 No solution provided
O18 The development does not                                                   Complies – The proposed
adversely impact on existing or                                              development on site will not
future electricity supply                                                    adversely impact on existing or
infrastructure;                                                              future electricity supply or
                                                                             infrastructure.
AND
                                                                              Complies - Premises is not
O19 All uses and works maintain an                                            located within 50m of an
adequate safe distance from                                                   electricity substation.
electrical infrastructure including
substations, overhead power lines,
power poles and transformers.
                                                                              Complies – Is not built
                                                                              within easement or overhead
                                                                              power lines.

                                      S19.1 Development for uses adjacent
                                       to or within 50m of an existing
                                       electricity substation incorporates
                                       noise attenuation measures to
                                       mitigate noise impacts;
                                      AND

                                      S19.2 Buildings and structures
                                       (including swimming pools, sheds,
                                       tennis courts and outbuildings) are
                                       not constructed under overhead
                                       electricity transmission lines, or
                                       within electricity easements




                                                                             Building Suncoast Green       21

Page 22

Noise                                 No solution provided    Complies – The proposed
O20 Development is designed and                               building design consists of tilt
sited to avoid noise emissions that                           slab construction with heavily
unreasonably diminish the amenity                             insulated roof. Limited
of the area or surrounding uses.                              openings
                                                              reduce the escape of sound.
                                                               The level of noise from the
                                                               operation is less than one
                                                              would expect from an
                                                              industrial activity.




                                                             Building Suncoast Green        22

Page 23

Mechanical plant and equipment
and storage areas                         S21.1 Mechanical plant and             Complies – All mechanical
O21 Mechanical plant and equipment        equipment are—                         plant and equipment will be
(including air conditioning equipment)    a) located more than 2m from           located on the ground at rear
and storage areas are designed and            any property boundary;             of building below Carpark
located to—                               b) where located at ground             level and screened by the
a) avoid adverse visual impacts               level, screened by fencing         retainment wall.
      when viewed from the street             1.5m in height or dense
      and adjoining properties; and           vegetation of at least 1.5m in
b) visually integrate with the building       width incorporating grouped
      design.                                 trees and shrubs with
                                              maximum separation distance
                                              of 1m measured from the
                                              centre of the tree or scrub;
                                              and
                                          c) are visually integrated into the
                                              line and plane of the building
                                              and roof design and do not
                                              project beyond the height or
                                              width of the building when
                                              viewed from the street and
                                              adjoining properties;
                                          AND
                                          d) S21.2 For Industrial                Complies
                                              business and Retail
                                              business Type 3, materials
                                              stored outside of a building
                                              do not exceed 4m in height
                                              or half the height of the on-
                                              site buildings whichever is
                                              the greater.


Safety and security
                                                                                 Complies
O22 All property boundaries are           S22.1 Boundaries are identified by
                                                                                 .
clearly identifiable with public and      such means as -
private spaces clearly defined.
                                          a)   fencing; or
                                          b)   changes in surface
                                               materials or levels; or
                                          c)   landscape treatments;




                                                                                Building Suncoast Green     23

Page 24

    column 1                                                        column 2
    Specific                                         Probable solutions (if code assessable)
   Outcomes                    AND
                               S22.2 Loading and storage areas are well lit or           Complies – Loading and
                               can be locked after hours.                                storage areas will be inside
O23 All premises and                                                                     both tenancies and locked
                               S23.1 All premises are identified by the
access routes are clearly                                                                outside of regular hours at all
                               provision of the street number in a prominent
identifiable to all persons,                                                             times.
                               location, preferably near the site entry, (i.e. on
particularly emergency         the kerb or letterbox or by signage on the
services personnel.                                                                      Complies- The Proposed
                               building or site).
                                                                                         development will have
                               S24.1 The number of entrances and exits are               signage to depict street
                               limited and main building entrances/exits are             number which
O24 All building entries       located at the front of the site, in view of the          will be easily identified.
are designed to be             street. Where this is not possible, due to site or
obvious and easily             existing building constraints, a well defined path        Complies – All entrances/
identifiable.                  is provided to the entrance/exit;                         exits will be easily identifiable.
                                                                                         Both tenancies have access
                               AND
                                                                                         doors facing the car parking
                               S24.2 All entrances/exits to buildings, are well lit      areas, and will be easily
                               and signed, and signage includes hours of                 identified. Exit doors will be
                               operation;                                                identified in accordance with
                                                                                         fire and safety requirements.
                               AND
                               S24.3 Entrances/exits are located to provide a            Complies - Lighting is
                               direct link to driveways and carparking areas;            provided over all entrances
                                                                                         and signage provides hours of
                               AND                                                       operation.
                               S24.4 Recessed doorways are avoided where
                               the recess is of sufficient size to conceal a             Complies
                               person. Where recessed doorways are
                               unavoidable, measures are used to enhance                 Complies – The doorways
                               safety, as follows—                                       are not recessed.
                               a)    good lighting installed;                           Complies - Windows and
                               b)    strategically placed mirrors installed;           main
                               c)    angled approaches provided; or                     entrances are located facing
                               d)    gates which restrict access provided.              onto the driveway and parking
O25 Uses are arranged          S25.1 Windows and main entrances are                     area allowing for casual
within buildings and on        positioned to allow for casual surveillance.             surveillance.
sites to enable external
areas to be monitored.                                                                  Complies – Communal
                               S26.1 Communal open spaces, including                   spaces are provided where
                               congregation and seating areas are situated             practical in the future business
O26 Communal open              where they are in the line of sight of windows,         use environment.
space, including               doors and/or balconies of buildings, or can be
congregation and seating       seen from a street or other public space.                 Complies – The building
areas, is located where it                                                               design, external lighting has
can be monitored.                                                                        been designed to minimise
                               S27.1 Buildings or structures that are visible          the
                               from a public street or laneway—                          opportunities for vandalism.

                               a)    avoid the use of solid fences and blank
O27 Buildings and                    walls which attract graffiti. Where solid
structures are designed              blank surfaces are unavoidable,
to minimise opportunities            measures in the form of landscaping,
for vandalism.                       creepers, murals, vandal resistant paint,
                                     etc are used;




                                                                                      Building Suncoast Green         24

Page 25

   column 1                               column 2
    Specific                 Probable solutions (if code assessable)
   Outcomes
                             b)    use toughened glass, security screens
                                   and other measures (but not including
                                   security shutters that obscure the view
                                   of shop fronts) are used in windows
                                   which are provided at ground level, to
                                   deter break and enters; and
                             c)    use hardy vandal proof materials
                                   and anti-graffiti paint are used in
O28 Lighting of                    the construction of buildings.
appropriate intensities                                                         Complies – Electrical
                             S28.1 Lighting of appropriate intensities is       contractors will install lighting
is provided to                provided which satisfies the requirements of
maximise safety.                                                                which meets Australian
                              Australian Standard AS1158: Public                Standard AS1158: Public
                              Lighting Code, unless otherwise specified in      Lighting Code, unless
                              this Code;                                        otherwise specified in this
                             AND                                                Code;
                             S28.2 External lighting of a graduated             Complies – The lighting design
                             intensity is provided which starts at a lower      achieves the solution.
                             level of brightness at the perimeter of the
                             site and rises to a higher level at the
                             entrance to buildings or at the centre of the
                             site;
                             AND
                                                                                Complies - Lighting spill has
                             S28.3 Lighting is directed onto the site and       been considered and will be
                             away from neighbouring properties;                 operated at acceptable levels
                             AND                                                and will not impact adjoining
                                                                                properties.
                             S28.4 Vandal-resistant lighting is used in
O29 Public toilets are       public and publicly accessible areas.              Complies - The lighting design
designed and constructed     S29.1 Public toilets are located in high           achieves the solution.
to—                          traffic areas;
a)    ensure the safety of
      all people using       AND                                                N/A
      them; and              S29.2 Features that may legitimise
b)    take advantage         loitering, such as seating or public
      of informal            telephones are not located within 20m of           N/A
      surveillance from      toilet entrances;
      adjoining uses
      and activities,        AND
                                                                                 N/A
      discouraging           S29.3 Entrances to public toilets are
      non-legitimate         visible from the street, footpath and other
      uses.                  activity areas on the site or adjoining
                             sites.                                             Complies

                             S30.1 Safe and convenient pathway access
O30 Premises have            is provided from the site to link to existing
accessibility to public      pathway networks that services public
transport.                   transport facilities;                         Complies
                             OR
                             S30.2 Direct pathway access is provided to
                             the public transport facility if the facility is
                             contained on site or within 50m from the
                             property boundary.




                                                                                 Building Suncoast Green            25

Page 26

     column 1                                 column 2
  Specific Outcomes              Probable solutions (if code assessable)
O31 Business Uses                  S31.2 Secure and convenient parking
are designed and constructed to    space for bicycles is provided on site in          Complies - Existing pathway
encourage users of the             accordance with AS2890.3 Bicycle Parking           network and access encourage
development to access the site by Facilities and Figure 14-1 Minimum                  walking and cycling.
means of foot or bicycle through Requirements for Bicycle Parking;
provision of appropriate end-of-   AND
trip facilities including bicycle
parking and shower/change           S31.3 Where at least 5 bicycle parking         Please refer to page 12 of the
                                    spaces are required in accordance with         planning report outlining the
rooms.
                                    Figure 14-1 Minimum Requirements for           proposed developments
                                    Bicycle Parking, end-of-trip cycle facilities  bicycle parking.
                                    are provided at the following rate:
                                    a) 1 locker per 2 bicycle parking spaces; and
                                    b) 1 shower cubicle with ancillary
                                    change rooms per 10 bicycle spaces or          Complies - A shower and
                                    part thereof;                                  change room is provided in
                                    AND                                           each tenancy

                                    S31.4 Bicycle parking spaces and cyclist          Complies – The bicycle
                                    facilities are designed in accordance with        facilities are designed
                                    AUSTROADS Guide to Traffic                        according to the standard.
                                    Engineering Practice, Part 14 – Bicycles,
                                    Section 10; AND                                   N/A

                                    S31.5 On-site pedestrian facilities such as
                                    seating and shade structures are provided in
                                    developments for the convenience of
                                    persons walking to the site.
                                    Figure 14-1 Minimum Requirements
                                    for Bicycle Parking



                                     Use                Minimum bicycle
                                                        parking
                                     Commercial         1 bicycle parking space
                                                                 2
                                     Business           per 50m or part thereof
                                                        of gross floor area.
                                     Entertainment &    1 bicycle parking space
                                                                 2
                                     Dining Business    per 50m or part thereof
                                                        of gross floor area.
                                     Industrial         1 bicycle parking space
                                                                   2
                                     Business Type      per 100m or part thereof
                                     2                  of gross floor area.
                                     Retail Business    1 bicycle parking space
                                                                 2
                                     Type 1 (if not a   per 50m or part thereof
                                     roadside stall)    of gross floor area.
                                     Retail Business    1 bicycle parking space
                                                                   2
                                     Type 2             per 100m or part thereof
                                                        of gross floor area.
                                     Retail Business    1 bicycle parking space
                                                                   2
                                     Type 3             per 100m or part thereof
                                                        of gross floor area.
                                     Retail Business    1 bicycle parking space
                                                                   2
                                     Type 6             per 100m or part thereof
                                                        of gross floor area.
                                     Retail Business    1 bicycle parking space
                                                                   2
                                     Type 7             per 100m or part thereof
                                                        of gross floor area.




                                                                                   Building Suncoast Green         26

Page 27

     column 1                                  column 2
   Specific Outcomes              Probable solutions (if code assessable)
                                                                                   Complies - Waste storage
                                  32.1 Waste storage areas, external storage       Area is contained within the
Site facilities                   areas and loading docks are situated to the      loading bay and screened from
O32 Waste storage areas,          rear of the building or under the ground;        view with appropriate
external storage areas and        OR                                               landscape
loading docks do not detract
from the visual amenity of        S32.2 With the exception of the access way,      Complies – Please refer to the
the streetscape or cause          waste storage areas, external storage areas      attached landscape plans for
nuisance to adjoining             and loading docks are visually screened by       details.
properties.                       landscaping or fencing.


Environment & heritage
values                            No solution provided                             Complies - The proposed
O33 There are no significant                                                       development is located within
adverse effects on the                                                             the industrial zone on land
biodiversity, natural              Advisory note                                   that has previously been
vegetation, native wildlife,       PSP24 – Effluent Disposal details               cleared and filled for
habitats, landscape quality,       requirements for the design and siting of       development purposes.
water quality or heritage                                                          Vegetation on site consists of
                                   effluent disposal systems where located
values, including those related                                                    regrowth, small to medium
                                   outside a sewerage service area.
to—                                                                                sized saplings and
a)    changes to natural           Compliance with PSP24 will be considered        undergrowth shrubs and
      drainage;                    as part of Council’s assessment of the          grasses which will need to be
b)    disturbance to any of the    plumbing and drainage application.              cleared for development.
      wetland systems;                                                             Erosion and sediment control
c)    management of landslide                                                      measures will be implemented
      and fire risk;                                                               during construction and
d)    erosion and the                                                              appropriate drainage networks
      transport of sediments                                                       will be put in place to ensure
      off- site;                                                                   minimal impact on the
e)    unmanaged public                                                             surrounding waterways from
      access;                                                                      runoff from the site. The site is
                       4
f)    effluent disposal ;                                                          not located within a landslide or
g)    changes to fauna                                                             fire risk area.
      habitat and behavior;
      and
h)    disturbance       of
      buildings       and
      features, including
      natural features, of
      heritage
      significance.




                                                                                Building Suncoast Green       27

Page 28

    Division 13 – Driveways and Parking Code

    column 1                                    column 2
 Specific Outcomes                P   Probable solutions (if code assessable)
14.113 General
O1 Vehicular access does          S1.1 Vehicular access is located and designed
not adversely impact on safety,   in accordance with AUSTROADS- Guide to
capacity and operations of the    Traffic Engineering Practice requirements for
existing or planned road          sight distance and Section 3 of AS2890.1
network, the proposed             Parking Facilities;
driveway, cycleways or            AND
                                                                              22
pedestrian pathway systems.       S1.2 Only one footpath crossing is provided ;
                                  AND
                                  S1.3 Driveways, other than within any
                                  setback have a maximum grade in
                                  accordance with Section 3 of AS/NZS 2890.1


O2 Driveways                      S2.1 Design of the driveway across the             Complies – The proposed
and crossovers—                   footpath is in accordance with Council’s           development will comply with
a) are suitable and safe for      Standard Drawings 9002 or 9005 as                  this requirement, please refer
    their intended use; and       appropriate for the particular type of             to attached site plan and
b) match Council                  development as annotated on the drawings;          engineering drawings reflecting
    infrastructure.               AND                                                these details of compliance.

                                  S2.2 Driveways are designed and                    Complies – The driveway is
                                  constructed in accordance with Council             designed in accordance with
                                  Standard Drawings 9014, 9019, 9020, 9021,          Council Standard Drawings
                                  as appropriate for the particular type of          9014, 9019, 9020, 9021 to be
                                  development as annotated on the drawings;          consistent for the particular
                                  AND                                                type of development as
                                                                                     annotated on the drawings
                                  S2.3 The change in grades in the driveways
                                  and ramps is in accordance with Section 3 of       Complies – Please refer to
                                  AS2890.1 Parking Facilities.                       attached Building Design
                                                                                     Drawings

O3 In commercial zoned            S3.1 Design of multi-tenanted developments         N/A - The proposed
areas, the number of              in commercial zoned areas include shared           development is not located
driveways across pedestrian       driveways and parking areas;                       within a commercial zone.
footpaths is minimised.           AND
                                  S3.2 Driveways are located so they abut
                                  existing driveways of adjoining development
                                  where practicable and reciprocal easements
                                  are created to reduce the sealed driveway
                                  width.

O4 Vehicular access does          S4.1 Footpath and kerb crossings are located       Complies - The proposed
not adversely impact on the       clear of existing storm water inlet structures,    development driveways and
capacity, operations and          water and sewerage infrastructure fittings, any    crossovers comply. Please
maintenance of the existing       other exiting utility infrastructure, existing     refer to attached Building
infrastructure;                   landscaping and vegetation.                        Design drawings for details.
AND

                                                                                     Complies - Existing vegetation
O5 Vehicular access does          S5.1 No solution provided                          within the road reserve will be
not adversely impact on the                                                          retained to enhance proposed
integrity of existing                                                                onsite landscaping, except
landscaping or native                                                                where provision is made for
vegetation.                                                                          the driveway access points.




                                                                                    Building Suncoast Green       28

Page 29

     column 1                                              column 2
     Specific                             Probable solutions (if code assessable)
O6 Outcomes
       Driveway run-off is             S6.1 For—                                            Complies – Please refer to
filtered prior to leaving the          a)    Ancillary dwelling unit, Multiple              attached Engineering
premises.                                    housing Types 1 or 2 if less than 5            Drawings reflecting this
                                             carparking spaces, Visitor                     compliance.
                                             accommodation Type 1 and Home-
                                             based business Type 3—the driveway
                                             is formed to drain to landscaped areas;
                                             and
                                       b)    for other uses—grease and oil arrestors
                                             or storm water quality improvement
                                             devices are incorporated into the design
                                             to treat run-off prior to run-off exiting
                                             from the premises.


     Table 14-50 — Car parking and manoeuvring

     column 1                                           Probable
Specific Outcomes
14.114 Carpark design and layout
O7 Sufficient carparking is            S7.1 The number of parking and loading              Please refer to page 12 of
provided to accommodate the            bays is not less than the minimum number            the planning report
number and type of vehicles            specified in Table 14-51 Vehicle Parking            outlining the proposed
likely to be generated by the          Requirements;                                       developments car parking.
development having regard to
the specifics of the use
including—
a)     the type and intensity of
       land use;
b)     any existing parking
       available on the site;
c)
O8     hours   of operation;
         The layout   of the           S8.1 Parking bays, manoeuvring areas,                Complies - Parking and
d)     likely numbers
development     provides   of users;   queuing areas, loading, setdown and pickup           maneuvering areas are clearly
e)     the peak
adequate,          parking
             clearly  defined          areas and driveways are designed to the              defined
       demand
and easily        periods of
             accessible—               standards set out in Sections 2 and 3 of
a)     uses  on  the
       on-site vehiclesite; and        Australian Standard AS 2890.1 Parking
f)     the availability
       parking   and of                Facilities (Part 1: Off-street Carparking) and
       alternative carparking.
       manoeuvring                     AS 2890.2 – Off-street Parking (Part 2:
       areas; and                      Commercial Vehicles);
b)     loading and                     AND                                                  Complies – One loading bay is
       manoeuvring areas               S8.2 The number of loading bays is not less          Provided.
       for delivery and                than the minimum number specified in Table
       service vehicles                14-51.
O9 Parking areas are                   S9.1 Carparking areas are accessed from             N/A
located where they will not            rear laneways where practicable.
unduly conflict with
pedestrians
O10   Provisionandis will
                     made notfor a     S10.1 Carparking spaces are provided for            Complies – Accessible
dominate the
reasonable      streetscape.
              number      of on site   people with disabilities at the rate specified in   parking is provided at the
carparking spaces identified           Section 2.4.5 of AS 2890.1 – Parking Facilities     calculated rate required (1) for
and reserved for people with           (Part 1: Off-street Carparking).                    the proposed development.
disabilities.
O11   Access and egress points         S11.1 Vehicle manoeuvring areas are                 Complies – Please refer to
do not impact on the safety            provided in accordance with Section 3 of            engineering drawings
and operations of the road             AS 2890.1 Parking Facilities (Part 1: Off-          attached for details.
system.                                street Carparking) so vehicles enter and
                                       leave the site in a forward gear.




                                                                                           Building Suncoast Green       29

Page 30

                      c                                       column 2
                 o                           Probable solutions (if code assessable)
O12 Parking l                             S12.1 At locations where pedestrian and             Complies – Please refer to
areas are        u                        vehicle conflicts are likely to occur –             engineering drawings
designed to - m                           a)    sight distances of at least 2.5 seconds of    attached for details.
a)               n
     provide a progressive                      travel time at the designated speed are
     reduction in1 speed                        provided;
     between the S external               b)    splayed corners on structures are
                 p
     road and internal  parking                 incorporated;
     spaces; e                            c)    landscaping is designed to allow clear
b)   ensure lowerc                              views;
     speeds near if                       d)    sign placement ensures that views
                 i
     areas of high                              are not impeded;
     pedestrianc
                 O
     activity through
     the use of u                         S13.1 In large open car parks with greater          N/A
     appropriatet road                    than 200 car parking spaces, a pedestrian
     geometry or c                        path between parking spaces is provided on
                 o
     devices designed                     every second aisle;
                 m
     to limit speed;
     and         e
c)               s distances
     maintain sight
     which are appropriate for
     the likely operating                 S14.1 No probable solution identified;              N/A
     speeds in all areas of
     potential
     pedestrian/vehicle and               S15.1 Lighting is provided in accordance with       N/A
     vehicle/vehicle conflict;            Australian Standard 1158.1:1997 - Road
                                          Lighting - Vehicular Traffic (Category
O13 A clearly defined                     V) Lighting - Performance Installation and
pedestrian network is                     Design Requirements.
provided
O16         that –use areas of
     In mixed                             S16.1 Resident carparking is limited to one         N/A
a)     is located
Business     centres  in residents
                          areas           space per dwelling unit or accommodation unit.
do not compete withwill
       where     people                   AND
       choose
customers      fortocarparking
                      walk;               S16.2 Resident carparking is not located in the     N/A
b)
spaces.ensures that pedestrian            road reserve or between the residential or
       movement through car               business building and the principal street
       parking areas or                   frontage.
       structures are along
O17 Caraisles   ratherareas
             parking      than across
                                 are      No solution provided                                Complies – Landscaping
       them; to—
landscaped                                                                                    areas are landscaped, please
a)     provide shade;                                                                         see attached landscape plans
O14 Provision
b)     maximiseisinfiltration
                       made for of                                                            for details.
pedestrian
       stormand watervehicular
                         run-off;
queues
c)        at conflict
       define    parking  points;
                             areas;
d)     reduce direct
O15 Parking
       visibilityareas
                   of carare lit
to provide
O18    parkingsecurity
     Development  areaswithfor
                            fromthe       No solution provided                                N/A
night-time
potential   tousers.
       external     viewpoints;
                generate
e)     soften
significant      views
              traffic  and of parking
                              hardstand
impactsareas
           gives appropriate
consideration to transport
                            23
and land use issues .




                                                                                             Building Suncoast Green       30

Page 31

                      co                                 column 2
                 lumn 1                   Probable solutions (if code assessable)
Motor Cycles &Specifi
                  Motor                                                                     Complies – Please refer
Scooters         c                       S19.1 For Commercial businesses,                   to attached Building
O19 DesignatedOutco
                  Motor cycle or         Entertainment & dining business,                   Design and Engineering
                 mes spaces
motor scooter parking                    Industrial business Types 1 and 2, Retail          drawings for details.
reduce the reliance on cars.             business Types 2, 4, 5, 6 and 7, Education
                                         Types 1 and 2, Open Space, Wellbeing
                                         Uses and Transport Types 1, 2, 3 and 4
                                         motor cycle parking spaces accord with
                                         Planning Scheme Policy PSP26 Motor Cycle
                                         & Motor Scooter Parking

O20 Car parks are designed to            S20.1 Grease and oil arrestors or storm           Complies – The
ensure run-off is treated to             water quality improvement devices are             development complies,
remove pollutants prior to leaving       incorporated into the design to treat run-        please refer to the
the premises.                            off prior to it leaving the premises.             attached civil
                                                                                           engineering drawings
                                                                                           for details.

O21 Carparking areas are                 No solution provided                              Complies - The
designed to ensure drainage without                                                        development complies,
the use of pumps or other electrical                                                       please refer to the
apparatus.                                                                                 attached civil engineering
                                                                                           drawings for details.

O22 Site layout and building             S22.1 Below ground components of                  Complies – Below
design provides for                      buildings, including car parks, do not            ground components of
soft landscaping to be                   extend beyond the above ground footprint          the proposed
established.                             to allow for the provision of landscaping,        development will not
                                         particularly within building setbacks.            adversely impact or
                                                                                           intrude on landscaping
                                                                                           areas, so as to comply
                                                                                           with this provision


Education Types 1, 2
or 3                                     S23.1 Paved setdown areas are provided        N/A
O23 Carparking and setdown areas         within the site;
are designed and located to facilitate   AND
their safe and efficient use.            S23.2 For a minimum of 50% of carparking
                                         spaces, pedestrian access to buildings is not
                                         across or through driveways, car parks,
                                         setdown or manoeuvring areas;
                                         AND
                                         S23.3 Carparking and setdown areas are
                                         visible from off-site.




                                                                                      Building Suncoast Green       31

Page 32

 Table 14-51 — Minimum vehicle parking requirements

Industrial Business—
                                                     2
Type 1 Warehouse                    1 space per 50m or part thereof of use area    N/A
                                    OR
                                                                              2
                                    For self storage units — 1 space per 500m
                                    of use area




                                                     2
Type 2 Production,                  1 space per 30m , or part thereof, of use      Complies – Refer to
                                                               2
alteration, repackaging             area, for areas up to 150m ;                   building design site plan
& repairing                         AND                                            for breakdown of
                                                     2
                                    1 space per 50m , or part thereof, of use      carparking analysis.
                                                                2
                                    area, for areas up to 500m ;
                                    AND                                            Unloading and loading of
                                                       2
                                    1 space per 100m , or part thereof, of         a single unit truck as
                                                                 2
                                    use area in excess of 500m ;                   prescribed can be
                                    AND                                            accommodated on site if
                                                          2        2               needed.
                                    a) for sites 1000m - 1999m a
                                         loading bay for a single unit truck
                                         of 12m x 3.6m; or




 DIVISION 17 - LANDSCAPING CODE
 14.130 Specific Outcomes and Probable Solutions for the Landscaping Code

                 column 1 Specific                             column 2
             Outcomes                                         Acceptable
                                                            solutions (if self
14.134 General requirements                                   assessable)
Streetscape and amenity                                        Probable
O1 Sufficient landscaped areas S1.1 Landscaped areas, not less (if
                                                           solutions thancode       Complies – Please refer to
are provided to—                                              assessable)
                                    the minimum areas and dimensions                attached proposed plans
a)    enhance the visual            specified in Tables 14-56 or 14-57,             and landscape plans for
      amenity and natural           are provided and maintained;                    details.
      landscape character of the    AND
      area, streetscape and local   S1.2 Landscaping is designed, planted and
      area;                         maintained in accordance with PSP3              Complies – Please refer to
b)    retain natural landscape      Landscaping Plants and Guidelines.              attached proposed plans
      features, such as rock                                                        and landscape plans for
      outcrops and existing large                                                   details.
      trees;
c)    retain existing native
      vegetation and enhance
      buffer areas around
      property boundaries;
d)    suit the relative size and
      nature of the
      development and its
      setting;
e)    reduce the visual impact
      of large or bulky structures
      and fencing along
      watercourses; and
f)    conceal service,
      carparking and loading
      areas of
      developments;
g)         screen incompatible land                                            Building Suncoast Green      32
           uses; and
h)    provide privacy between
      any dwelling units and

Page 33

Building and landscape                                                                Complies – Below ground
design                              S2.1 Below ground components of                   components of the proposed
O2 Site layout and building         buildings do not extend beyond the above          development will not
and landscape design—               ground footprint to allow for landscaping         adversely impact or intrude
a) provides for soft                particularly within building setback areas;       on landscaping areas, so as
     landscaping to be              AND                                               to comply with this
     established in and                                                               provision.
     around the
     development;                   S2.2 Basement carparks do not                     N/A
                                    encroach into building setback areas;
b)   maximises the retention of     AND
     large canopy trees;            S2.3 Plants are grouped in mulched beds           Complies – Please refer to
c)   within the Eastern Beaches     rather than planted individually to provide for   attached proposed plans
     Locality and Noosa Heads       optimum growing conditions and less               and landscape plans for
     Locality, avoids the removal   maintenance;                                      details.
     of heath vegetation, except    AND
     where required for internal    S2.4 These plants grouped in mulched
     roads and service and          beds are not subject to any hedging               Complies – Please refer to
     infrastructure construction;   maintenance regimes; AND                          attached proposed plans
                                                                                      and landscape plans for
d)   minimises the extent of        S2.5 Landscaping is designed, planted and         details.
     impervious paved areas;        maintained in accordance with PSP3
e)   provides for suitable          Landscaping Plants and Guidelines;                Complies – Please refer to
     plant layouts and              AND                                               attached proposed plans
     densities;                                                                       and landscape plans for
                                    S2.6 Alternatives to impervious pavement          details.
f)   facilitates the adoption       are provided and are located where
     of appropriate planting        landscaping and existing vegetation will
     techniques; and                benefit from increased infiltration of
g)   considers on-going             rainwater.
     maintenance requirements
     to assure the establishment
     and ongoing survival of
     plantings.




Species selection
O3 Landscaped areas include         S3.1 Plantings—                                   Complies – Please refer to
plant species that—                 a) comprise plant species identified for the      attached proposed plans
                                        relevant landscape character area in          and landscape plans for
                                        PSP3 Landscaping Plants and                   details.
                                        Guidelines; and




                                                                                Building Suncoast Green      33

Page 34

                        colu                                column 2
                 mn 1                            Acceptable solutions (if self
                 Specific                   assessable) Probable solutions (if
                 Outcome
a) are appropriate        to the                       code assessable)
                                        b) avoid undesirable     plant species
     biophysical s conditions and       identified in
     landscape character of the             PSP3 Landscaping Plants and                    N/A
     area;                                  Guidelines;
b) are suitable for the space           OR
     available, the level of visual
     and climatic exposure, the         S3.2 For landscaping around pool
     functional requirements of         areas—
     the site and the scale of the      a)     no more than 30% of the landscaped
     development;                              area is a mixture of plants of local
c) provide for appropriate                     origin and exotic plant species,
     levels of shade and                       provided none of the plant species are
     sunlight to occupants of                  undesirable plants identified in PSP3
     the development                           Landscaping Plants and Guidelines;
     throughout the year;                      and
d) minimise the demand for water b)            palms are specifically located in
     use;                                      group plantings in accordance
e) in road reserves, provide                   with PSP3 Landscaping Plants
     street trees with effective               and Guidelines;                             N/A
     canopy shading having              AND
     regard to the size and scale       S3.3 Root guards are utilised around
     of the road reserve and the        species with potentially invasive roots.
     location of services and
     other structures;
f) for street trees in towns
     are villages, are consistent
     with the existing
     streetscape character;
g) do not cause
     potential damage to
     buildings
Safety            or
          and security
O4 structures;
       Landscaping is designed          S4.1 No solution provided.                      Complies – Please refer to
h) located
and  are not harmful
               to maximiseto the                                                        attached proposed plans
     pedestrians,
safety  and security  particularly
                         of public and                                                  and landscape plans for
                                        Figure 14-16 — Landscaping
     around
private   areasschools,
                 by— childcare                                                          details.
                                        allows for adequate safe vision at
a) centres,      shopping
      clearly defining    theareas and
                                        driveways and intersections
     other   high pedestrian
      boundaries     between areas;
i) in    intensively
      private         used spaces;
               and public
b) environments,
      promoting casual  can
     endure    high levels
      surveillance            of
                      of buildings  and
     activity;  and from the street
      public areas
j) forandrural  residential
            other  public areas for
     developments,
      personal security  arereasons;
                              best
c) suited
      avoidingto less  intensive spots;
                  concealment
     maintenance
      and              and low
d) availability
      maintainingofsafewater   for
                            sight
     gardens.
      distances to and from road
      and building corners, carpark
      entrances and driveways
      (see Figure 14-16);
e) maintain safe sight distances
      at planting bed ends within
      carparks;
f)    protecting solid fences from
      graffiti by incorporating
      elements such as
      landscaping, creepers,
      murals or vandal resistant
      paint; and
g) separating and defining
      pedestrian and vehicle
      circulation routes.
                                                                                  Building Suncoast Green      34

Page 35

                  colum                                 column 2
             n1                                Acceptable solutions (if self
             Specific                        assessable) Probable solutions
O5           Outcomes
      The provision of                            (if codeprovided
                                        S5.1 Landscaping   assessable)
                                                                   which allows          Complies – Please refer to
landscaping is to a satisfactory        adequate visibility for casual surveillance      attached proposed plans
standard ensuring that it does not      of public and semi-public spaces, including      and landscape plans for
lead to opportunities for               entrances and exits to sites and buildings,      details.
concealment and possible assault        by:
sites.                                  a) planting trees which have clean
                                             trunks to a height of at least 1.8 m;
                                             and
                                        b) appropriately spacing shrubs at 1.2m
                                             horizontal centres, with a maximum
                                             height of 0.75m, to avoid clumping
                                             and to retain sightlines.                   Complies – Please refer to
                                         S6.1 Street trees and trees in carparking       attached proposed plans
O6 Street trees and plantings            areas achieve a maximum of 900mm                and landscape plans for
in towns and villages, carparks          clear trunk height for a 2.0m high tree at      details.
and other areas where potential          planting and are able to attain a clear
conflicts with vehicles and              trunk height of 1900mm on maturity; AND         Complies – Please refer to
pedestrians are evident, are            S6.2 All scrub planting to be a maximum          attached proposed plans
planted so as to maximise               height of 700mm from the road pavement           and landscape plans for
vehicle and pedestrian safety.          (not top of kerb).                               details.
Services and utilities
O7 All landscaping works                S7.1 Plant species used in landscaping           N/A
maintain adequate safe distance         adjacent to substations, or adjacent to or
from services and utilities including   on electricity transmission line easements,
substations, overhead powerlines,       are less than 4m high at maturity and do
power poles and transformers,           not encroach within 3m of a substation
street lamps, stormwater                boundary;
catchment pits, and underground         OR
services and utilities.                 S7.2 For trees higher than 4m, trees are
                                        planted at a distance from any part of an
                                        electricity transmission line at least equal
Figure 14-17
                                        to the expected height of the tree at
                                        maturity (see Figure 14-17); AND
                                        S7.3 For power lines that connect to a
                                        premises, the height of plant species at
                                        maturity provides for a 2m clearance
                                        below the power line; (see Figure 14-18)
                                        AND
                                        S7.4 Trees and large scrubs are
                                        located a minimum of—
                                        a)      5m from electricity poles and pillars;
Figure 14-18                            b)      4m from street lamps;
                                        c)      2m from stormwater catchment pits;
                                                and
                                        d)      2m from underground services and
                                        utilities; AND
                                        S7.5 Plants are located to enable
                                        tradespersons to access, view and inspect
                                        service meters, such as water and
                                        electricity meters;
                                        AND
                                        S7.6 Root barriers are installed around
                                        trees that are located within 3m of any
                                        infrastructures or that have potentially
                                        invasive roots.




                                                                                   Building Suncoast Green      35

Page 36

Industrial Business
O20 Landscaping within                No solution provided                           Complies – Please refer
industrial developments                                                              to attached proposed
is designed to—                                                                      plans and landscape plans
                                      Figure 14-25 Appropriate species at
a) maximise retention of existing                                                    for details.
                                      correct density and height effectively
     vegetation;
                                      screen bulky industrial buildings
b) provide planting in mulched
     areas at entrances, along
     boundaries and around car
     parking and site facilities to
     provide screening and
     shading;
c) lessen the impact of building
     bulk though the planting of
     vegetation that is in scale
     with the building, and by
     using mounding where
     appropriate (see Figure 14-
     25); and
d) provide outdoor areas for staff.




14.139 Carparking areas
Off street carparks
                                                                       28
O28 Landscaping of carparking         S28.1 One advanced canopy tree (a              Complies – Please refer
areas is designed to—                 minimum of 100 litres pot size) is             to attached proposed
a) reduced the visual                 provided—                                      plans and landscape plans
     impact of the                    a)       in towns and villages, shopping       for details.
     development;                              centres or commercial areas— for
b) provide         for    advanced             every 4 carparking spaces; or
     canopy trees to shade            b)       otherwise—for every 6 carparking
     vehicles and to reduce           spaces; AND
                                                                      2
     reflected radiation;             S28.2 A minimum area of 5m is provided
c) ensure canopy trees are            around each canopy tree, which is
     protected from vehicle           mulched and treated;
     damage by providing              AND
     adequate sized garden beds;      S28.3 Plants are grouped in mulched beds
d) maximise opportunities for         rather than using individual, evenly spaced
     infiltration of rainwater on-    trees and scrubs;
     site; and                        AND
e) minimise contaminated              S28.4 Semi-pervious pavement surfaces
     runoff entering the              are used, such as grass cell paving, to
     stormwater system and            increase infiltration of rainwater and
     watercourse.                     minimise contaminated runoff, including
                                      hydrocarbons, entering the stormwater
                                      system and watercourses;
                                      AND
                                      S28.5 Runoff from carparking areas is
                                      directed to landscaped areas to minimise
                                      contaminate runoff, including
                                      hydrocarbons, entering the stormwater
                                      system and watercourses;




                                                                               Building Suncoast Green    36

Page 37

                colum                                    column 2
            n1                              Acceptable solutions (if self
            Specific                      assessable) Probable solutions
            Outcomes                 AND          (if code assessable)
                                     S28.6 Garden mounding is
                                     incorporated into carparking areas
                                     adjacent to frontages; AND
                                     S28.7 Surface and subsurface drainage
                                     swales are used to maximise storm
                                     water infiltration; AND
                                     S28.8 A planting bed of at least 1m width
                                     with screen fencing and dense planting is
                                     provided to any property boundary with an
                                     adjacent residential development.
On-street car parks
O29 Edges to parking and turning     S29.1 Where vehicles are parked parallel to   Complies – Please refer
spaces for on street parking are     the kerb, landscaping is setback a minimum    to attached proposed
landscaped to provide shade and      of 500mm from the back of the kerb to allow   plans and landscape plans
screening, while ensuring adequate   adequate access (see Figure 14-27);           for details.
access to vehicles.                  AND
                                     S29.2 Street trees are planted a minimum
Figure 14-27 Allow 500mm for
                                     of 1m from the back of the kerb in the road
passenger access
                                     reserve verge.




                                                                            Building Suncoast Green     37

Page 38

Building Suncoast Green   38


[OCR of page images]
 

Building Suncoast Green

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.