Original source · versioned page text
Slope Stability - lindsays
REINFORCED WALLS FOR WIND CATEGORY - N3 190mm WALL
LINTEL SIZE - refer table LINTEL SIZE - refer table
LINDSAY CONSULTING PTY LTD
1/N16 LINDSAY CONSULTING PTY
LTD
RPEQ 4928
OFF. 2C/82 PARKER STREET, MAROOCHYDORE PH 54 792 118
THIS DRAWING REMAINS THE PROPERTY OF
LINDSAY CONSULTING PTY LTD AND IS FOR
N16 at 400 max centres 0ver 2400 to 3000 max THE SOLE USE OF THE CLIENT. NO PART
2400 max. MAY BE USED IN PART OR WHOLE WITHOUT
PRIOR EXPRESS WRITTEN CONSENT OF
LINDSAY CONSULTING PTY LTD
CLIENT AND PROJECT DESCRIPTION
GUY MELDRUM
PROPOSED RESIDENCE
NO.4 TRISTANIA DRIVE
1/N16 at
corners
1/N16 both
sides of
1/N16 extra in 2nd or
3rd core both sides of
1/N16 both
sides of
1/N16 under
all window sills MARCUS BEACH
opening openings over 2400 opening
All construction to be in accordance with the Besser
Technical Specification " Solid Besser Home System
Simplified Design" using Besser products. Refer to relevant DRAWING TITLE
manufacturers specification if using other products BLOCKWORK DETAILS
BESSER 20.25 BESSER 20.20
60
60
OR 20.26 SCALES
215
290
W8 stirrups at 200
centres in S lintels
460
BESSER 20.20
590
TYPE A LINTEL
W8 stirrups at 200
centres in S lintels
60
SURVEY DATUM
BESSER 20.20
BESSER 20.12 .
0R 20.15
315
W8 stirrups at 200
390
centres in S lintels ASSOCIATED CONSULTANTS
BESSER 20.12 TYPE C LINTEL
0R 20.15
60
TYPE BB LINTEL
60
BESSER 20.20 BESSER 20.20
260
W8 stirrups at 200
390
centres in S lintels
700
BESSER 20.12 BESSER 20.20
790
0R 20.15 LINTEL CODE REINFORCEMENT
REVISION LIST
A BUILDER REVIEW - NOT FOR CONSTRUCTION 25/03/22
W8 stirrups at 200 A212 B212 BB212 C212 D212 2-N12 top and bottom
TYPE B LINTEL centres in S lintels A116 B116 BB116 C116 D116 1-N16 top and bottom
A212S B212S BB216S C212S D212S 2-N12 top and bottom W8 stirrups at 200 centres
BESSER 20.12 A116S B116S BB116S C116S D116S 1-N16 top and bottom with W8 stirrups at 200 centres
0R 20.15 A216 B216 BB216 C216 D216 2-N16 top and bottom
A216S B216S BB216S C216S D216S 2-N16 top and bottom with W8 stirrups at 200 centres
A220 B220 BB220 C220 D220 2-N20 top and bottom
A220S B220S BB220S C220S D220S 2-N20 top and bottom with W8 stirrups at 200 centres
TYPE D LINTEL
Computer File
220061FD.DWG
DRAWING NUMBER SHEET REV.
22-0061-F12 12 A