Original source · versioned page text
Slope Stability - lindsays
LINDSAY CONSULTING PTY LTD
LINDSAY CONSULTING PTY
LTD
RPEQ 4928
OFF. 2C/82 PARKER STREET, MAROOCHYDORE PH 54 792 118
THIS DRAWING REMAINS THE PROPERTY OF
LINDSAY CONSULTING PTY LTD AND IS FOR
THE SOLE USE OF THE CLIENT. NO PART
MAY BE USED IN PART OR WHOLE WITHOUT
PRIOR EXPRESS WRITTEN CONSENT OF
LINDSAY CONSULTING PTY LTD
R.C. SLAB ON GROUND
CLIENT AND PROJECT DESCRIPTION
GUY MELDRUM
N12 @ 200 CRS top and bottom U.N.O. PROPOSED RESIDENCE
Bottom laid second, top laid third.
NO.4 TRISTANIA DRIVE
SUSPENDED SLAB TO LAP MIN. MARCUS BEACH
800mm INTO SLAB ON GROUND.
REFER FOUNDATION DETAILS
DRAWING TITLE
STRUCTURAL PLAN
id
SHOWER RECESS vo
id SCALES
vo
N12 @ 200 CRS top and bottom U.N.O.
0 1 2 3 4m
Provide 5-N12
Bottom laid first, top laid fourth.
intermediate top
bars 1.0m long
Orig. 1:100
N12 bars @ 150 CRS each way SURVEY DATUM
Provide 3-N12 top
steel trimmer bars
top and bottom to terrace area
(external slab)
.
6-N16 Bars (@ 200 crs) INTERNAL SLAB EXTERNAL SLAB EXTERNAL SLAB ASSOCIATED CONSULTANTS
bottom steel, 5m long min, EXPOSURE CLASSIFICATION A1 A1 (ENCLOSED) B2 (EXPOSED)
each way.
CONCRETE STRENGTH 32 MPa 32 MPa 40 MPa
N12 bars @ 150 CRS MINIMUM COVER 20 mm Top & Bottom 20 mm 45 mm
each way top and bottom
to lower roof area 6-N20 starter bars
with 1.0m lap. Suspended slab reinforcement and
thicknesses as per engineering
400x300 concrete column
with 6-N20 cage with N12 N12 starters @ 400
N20 longitudinal beam Concrete beam requires ligs @ 300 CRS CRS. 500 laps min.
bars to be cogged top 3-N20 bars top and bottom
and bottom with N12 ligs @ 300 CRS.
SLAB THICKNESS NOMINATED IS MINIMUM
x
REINFORCEMENT BARS ARE REQUIRED TO 1200mm min. lap length.
DEPTHS. BUILDER SHALL INCREASE THE REVISION LIST
HAVE THE TYPICAL COG DETAIL ON ALL A BUILDER REVIEW - NOT FOR CONSTRUCTION 25/03/22
CANTILEVERED SLAB EDGES SLAB WHERE NECESSARY TO PROVIDE
FALL AS SHOWN BY ARCHITECT Blockwork reinforcement
DRIP NOTCH REQUIRED ON ALL as per engineering
CANTILEVERED SLAB EDGES
SUSPENDED SLAB HAS BEEN DESIGNED TO NOT REQUIRE
ANY LOAD BEARING LINTELS. THEREFORE, WE HAVE NOT
GROUND FLOOR SUSPENDED SLAB PLAN SPECIFIED ANY LINTEL SIZES. BUILDER SHALL FIX INTO
SUSPENDED SLAB WITH N12 STARTERS @ 400 CRS. TYPICAL SUSPENDED SLAB SECTION Computer File
220061FD.DWG
SCALE 1:100 NOT TO SCALE DRAWING NUMBER SHEET REV.
22-0061-F15 15 A