Slope Stability - lindsays
N12 @ 200 CRS top and bottom to main residence. Bottom laid first, top laid fourth N12 @ 150 CRS top and bottom to terrace & pool surround. Bottom laid first, top laid fourth
Void LINDSAY CONSULTING PTY LTD
LINDSAY CONSULTING PTY
N12 @ 200 CRS top and bottom to terrace & pool surround.
LTD
RPEQ 4928
OFF. 2C/82 PARKER STREET, MAROOCHYDORE PH 54 792 118
Direction of N12
THIS DRAWING REMAINS THE PROPERTY OF
reinforcement bottom Provide N12 top steel Provide N12 top steel LINDSAY CONSULTING PTY LTD AND IS FOR
Bottom laid second, top laid third.
laid first top laid fourth.
intermediates 2.0m intermediates 2.0m THE SOLE USE OF THE CLIENT. NO PART
450mm min. laps.
long each way. MAY BE USED IN PART OR WHOLE WITHOUT
long each way. PRIOR EXPRESS WRITTEN CONSENT OF
LINDSAY CONSULTING PTY LTD
C3 C1 Direction of N12
PROPOSED POOL CLIENT AND PROJECT DESCRIPTION
reinforcement bottom laid
GUY MELDRUM
PROPOSED RESIDENCE
second top laid third.
450mm min. laps.
NO.4 TRISTANIA DRIVE
N12 @ 200 CRS top and bottom to main residence.
MARCUS BEACH
Bottom laid second, top laid third.
C4
DRAWING TITLE
void
STRUCTURAL PLAN
C4 SCALES
N12 bars @ 150 CRS each way
top and bottom to terrace area
id
vo
0 1 2 3 4m
(external slab)
Orig. 1:100
Provide 3-N12 top
steel trimmer bars SURVEY DATUM
.
INTERNAL SLAB EXTERNAL SLAB EXTERNAL SLAB
C1
EXPOSURE CLASSIFICATION A1 A1 (ENCLOSED) B2 (EXPOSED)
N12 bars @ 150 CRS each way CONCRETE STRENGTH 32 MPa 32 MPa 40 MPa ASSOCIATED CONSULTANTS
top and bottom to terrace area
(external slab) MINIMUM COVER 20 mm Top & Bottom 20 mm 45 mm
C3 REINFORCEMENT BARS ARE REQUIRED TO
HAVE THE TYPICAL COG DETAIL ON ALL
N20 longitudinal beam CANTILEVERED SLAB EDGES
bars to be cogged top Suspended slab reinforcement and
and bottom thicknesses as per engineering
DRIP NOTCH REQUIRED ON ALL
CANTILEVERED SLAB EDGES N12 starters @ 400
CRS. 500 laps min.
400x300 concrete angled Concrete beam requires
SLAB THICKNESS NOMINATED IS MINIMUM
x
column with 6-N20 cage 3-N20 bars top and bottom
with N12 ligs @ 300 CRS. with N12 ligs @ 300 CRS. DEPTHS. BUILDER SHALL INCREASE THE REVISION LIST
A BUILDER REVIEW - NOT FOR CONSTRUCTION 25/03/22
6-N20 starter bars with 1200mm min. lap length. SLAB WHERE NECESSARY TO PROVIDE
1.0m lap. FALL AS SHOWN BY ARCHITECT Blockwork reinforcement
as per engineering
SUSPENDED SLAB HAS BEEN DESIGNED TO NOT REQUIRE
ANY LOAD BEARING LINTELS. THEREFORE, WE HAVE NOT
FIRST FLOOR SUSPENDED SLAB PLAN SPECIFIED ANY LINTEL SIZES. BUILDER SHALL FIX INTO
TYPICAL SUSPENDED SLAB SECTION Computer File
SUSPENDED SLAB WITH N12 STARTERS @ 400 CRS. 220061FD.DWG
SCALE 1:100 NOT TO SCALE DRAWING NUMBER SHEET REV.