WATER SENSITIVE DESIGN CODE
Performance Criteria and Acceptable Solution
Hofmann Drive Medical Centre
1 August 2018
Issue A
PERFORMANCE OUTCOMES ACCEPTABLE OUTCOMES RESPONSE
Use of natural treatments and systems
PO7 AO7.1 RO7
Natural treatment strategies, including grass swales and No probable solution Not applicable - Proprietary filters are proposed to be
bio-retention systems, vegetated filtration strips and gross constructed as part of the development instead of vegetated
pollutant traps, are used wherever possible. assets due to site constraints. Refer to the Stormwater
Management Plan prepared by MPN Consulting for further
information.
PO8 AO8 RO8
Development design including density and scale provides Integration of stormwater quality treatment is in Not applicable - Proprietary filters are proposed to be
adequate footprint to integrate all elements of stormwater accordance Healthy Waterways Water Sensitive Urban constructed as part of the development instead of vegetated
quality and quantity treatment infrastructure including, Design Guidelines for South East Queensland and the assets due to site constraints. Appropriate maintenance
where relevant, bio retention basin batters and maintenance Water by Design Bio retention Technical Design access will be provided to the proposed stormwater quality
access, without the need for retaining walls. Guideline. treatment devices. Refer to the Stormwater Management
Plan prepared by MPN Consulting for further information.
PO9 AO9.1 RO9.1
Stormwater conveyance channels use natural channel Landscape and ecological features (e.g. plant species and Not applicable – No open stormwater conveyance channels
design principles to convey external catchment stormwater habitat types) used in stormwater conveyance channels are proposed to be constructed as part of the development.
through the development site and support landscape, are complementary to the local context, including natural
passive recreation and ecological values. waterways;
AND
AO9.2 RO9.2
Planting densities result in a stable channel over the long Not applicable – No open stormwater conveyance channels
term and minimize potential for invasive weed growth. are proposed to be constructed as part of the development.
l:\7000-7999\7700-7799\7700\codes\01-08-18 water sensitive design code.docx
Page 4
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.