lore Tm
Ay exe LimOL LCL

Site cover, gross floor area and plot ratio

06 The site cover, gross floor area and plot ratio of

buildings and other roofed structures—

a) results in a building scale that is compatible with
surrounding development;

b) does not present an appearance of excessive bulk
to adjacent properties, roads or other areas in the
vicinity of the site;

c) maximises the retention of existing vegetation and
allows additional soft landscaping between
buildings;

d) allows for adequate area at ground fevel for
outdoor recreation, entertainment, clothes drying
and other site facilities; and

e) facilitates onsite stormwater management and
vehicular access.

07 _ Site cover does not exceed—

a) for the Detached Housing Zone-50% for a single

storey building and 40% for a double storey building;

b) for the Semi-attached Housing Zone-40%;

c) for the Attached Housing Zone—

i in Sunshine Beach-35%; or
ii otherwise-40%; or

d) for the Visitor Mixed Use Zone-35%.

08 Multiple Housing Type 2 -...

O09 ‘For Multiple housing Type 3 or 4, Visitor

accommodation Type 4 or the accommodation unit
component of an Entertainment and dining business
Type 3 (hotel)—the maximum gross floor area is
equivalent to the maximum allowable population density in
persons multiptied by 40m’, provided that Lots 75-77 on
P9311 Heron Street, Peregian Beach, have a maximum
gross floor area of 1200m’.

010 For the Detached Housing Zone and Semi-
attached Housing Zone—soft landscaping is provided and
retained over a minimum of 20% of the site area.

Roof form
013 Roof forms—

a) contribute positively to the local skyline;

b) complement the beachside character of the
locality;

¢) use soft and articulated pitched or curved roof
forms;

a Column 2 an

Lefeol erie) Role Lee R ESSE}

No solution provided

4

$13.1 The main roof of the building has a roof pitch no less
than 5 degrees and has roof overhangs a minimum of 600mm
wide;

AND

$13.2 Buildings and structures do not include roof top terraces.

 

 

Column 3
Compliance

Complies

Complies — The proposed development has a site cover of
39%.

Not Applicable

Complies ~ A maximum gross floor area of 2352.4m? is
allowable. The proposal has a gross floor area of 770m’.

Complies — soft landscaping is provided over a large area of
the site.

New buildings to incorporate pitched roof forms, eaves and
awnings. Existing dwelling to retain its existing flat roof.

Complies - no roof top terraces

 

00786 Staley - Hoste!

page 4

 

 

Used in these records

About this file

File size
4.3 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

08_0299 - MCU - Visitor Accommodation Type 4 - Visitor Hostel [As Published].pdf · 4.3 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.