Council archive · source document
08/0299 - MCU - Visitor Accommodation Type 4 - Visitor Hostel [As Published] · 132008.299
Column 1
Specific Outcomes
Column 2
Probable Solutions {if code assessable)
bere Te)
Compliance
O8 The provision of an effluent disposal system is
provided to maintain acceptable public health standards
and avoid environmental harm.
14.81 Amenity
Cc) operated to support the efficient use of water. OR
$7.1 If in a designated rainwater tank area as identified on Map
1 of Schedule 8, visitor accommodation that qualifies as class
4A or 1B structures under the Building Code of Australia has a
rainwater tank or tanks in accordance with Schedule 8.
Effiuent disposal
No solution provided
Complies — The subject site is able to be connected to the
existing sewerage system.
Safety and security
09 For Visitor accommodation Type 4, buildings and
outdoor spaces are designed to protect the personal
security and safety of residents by allowing for natural
surveillance
$9.1 The building entrance is clearly identifiable and visible
from the street, footpath and driveway;
AND
$9.2 The internal path network has clear sightlines to the
dwelling entry and street access points;
AND
$9.3 Visitors have direct access to the entrance without
passing through private open space areas.
Complies — The building entryway is cleared defined from the
street, footpath and driveway.
Complies — The entryway path has a clear sight line to the
accommodation entry and street access.
Complies — Visitors are not required to pass through private
open space.
Emergency access
010 For Visitor accommodation Type 2 or 4, site
design and Jayout ensures efficient access and egress for
emergency vehicles.
No solution provided.
Complies — Due to the three street frontages and driveway
access, the site is easily accessible for emergency vehicles.
Table 14-34 — Type 4 — Conventional (Visitor hostel)
| 14.85 Effects of Use
| Siting
030 Visitor hostels are established close to natural
attractions and urban services and facilities where they do
not unduly impact on residential amenity.
No solution provided
Complies - Site is located in close proximity to the commercial
services of the Sunshine Beach commercial precinct as well as
the natural attractions of Sunshine Beach and Noosa National
Park.
Scale
031 Visitor hostels are at a scale and density compatible
with surrounding land uses.
No solution provided
Complies — The proposal is of a scale and density compatible
with the surrounding residences, as the proposal complies with
the Site Cover, GFA and building height requirements of the
Semi-Attached Housing zone.
It is highlighted that the applicant is reusing and extending
existing buildings on site to ensure the development is
compatible with the surrounding area.
00786 Staley Hostel
Visitor Accommodation Code
page 2
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
08/0299 - MCU - Visitor Accommodation Type 4 - Visitor Hostel [As Published]Related documentApplication case desk ↗
About this file
- File size
- 4.3 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.