Original source · versioned page text
Noise Report 54 Boronia Road MCU17-0546
Allstar Metal Fabrication Environmental Noise Level Impact Assessment of Metal Fabrication Business, 54 Boronia Road, Cootharaba Page 5 of 17 LA90,T: daytime: 40.7, 37.4, 40.3, 43.1, 40.5, 38.7, 38.4 Average = 39.9 dB(A); evening: 57.5, 58.0, 57.6, 54.1, 44.0, 49.6, 43.7 Average = 52.1 dB(A); night-time: 60.1, 60.7, 62.0, 61.6, 61.4, 61.4, 61.3 Average = 61.2 dB(A). It should be noted that for the ambient noise assessment there were no adverse weather conditions (such as rain – no rain for all days of sampling) or extraneous noise events which warranted any of the collected noise data to be excluded from the averaging process. Refer Appendix C for meteorological details for the closest recording station to Cootharaba, namely Double Island Point. APPLICABLE NOISE LIMITS All noise sources associated with Allstar Metal Fabrication are enclosed (located inside a building) and, therefore the requirements of SC53.3 are complied with. In accordance with SC53.2 any noise from Allstar Metal Fabrication must be inaudible beyond the boundary of the subject site, namely 54 Boronia Road. To the east the boundary is approximately 80 metres from the closest part of the Allstar Metal Fabrication building. At this location noise from Allstar Metal Fabrication must not exceed the average ambient daytime noise levels less 10 dB(A) to effectively be not more than the average ambient daytime noise level, namely: 52 – 10 = 42 dB(A) LAeq,15min; 64 – 10 = 54 dB(A) LA1,15min; 54 – 10 = 44 dB(A) LA10,15min. SOURCE NOISE LEVEL MEASUREMENTS In September 2017 source noise level measurements were obtained at a distance of 15 metres from the eastern end of the Allstar Metal Fabrication building, with the closest boundary approximately 80 metres distant. These noise level measurements did include some noise of bird calls, but were dominated by noise from Allstar Metal Fabrication, including grinding, compressor, metal cut-off saw, metal guillotine and metal impact noise (metal on metal noise). Table 2 details the results of these noise level measurements and Figure 2 is a graphical presentation of a representative part of the monitoring, for the nominated parameters. Table 2 Source Noise Level Measurement Results 15m from Eastern End of Allstar Metal Fabrication Building Noise Level, dB(A) Time Comment LAeq,10min LA1,10min LA10,10min 1050-1100 42.8 49.5 45.8 Noise of hammering, 1100-1110 43.7 48.6 45.4 grinding, metal cut-off saw, metal guillotine and 1110-1120 43.9 50.4 45.8 compressor. Also some noise of birds – 52, 52, 53, 1120-1130 43.6 49.5 45.7 55, 55 and 56 dB(A) 1130-1140 43.9 47.6 45.9 maximum. AVERAGE 43.6 49.8 45.8 David Moore & Associates Pty Ltd Our reference: R17078/D3286/Rev.1/2.04.18
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.