Council archive · source document
RFI - App E - Amended Noise Impact Assessment · 132008.299.02
RG Strategic #70250009-ENAC-RPT01-R3
Dolphin Backpackers – 14-16 Duke Street, Sunshine Beach 14 September 2026
Noise Impact Assessment
5.7.4 Fixed Mechanical Plant
Mechanical plant associated with the development comprises:
• Wall mounted split-system air-conditioning condenser units serving dormitory rooms;
• A roof mounted kitchen exhaust fan associated with the shared kitchen; and
• Pool pump (Onga/Pentair Pantera PPP-750-1P pump).
The proposed air-conditioning systems comprise of Mitsubishi Electric MSZ-AP35VG (indoor) /
MUZ-AP35VG (outdoor) split-system units as nominated by the Applicant. Manufacturer data for
the outdoor condenser unit specifies a maximum A-weighted sound power level (SWL) of 64 dBA.
For the purposes of the noise model, each outdoor condenser unit has been represented as a
point source with the following parameters:
• Sound Power Level (SWL): 64 dBA per unit;
• Externally located adjacent to each dormitory; and
• Positioned 0.5 m above the respective finished floor level (FFL):
o Ground Floor FFL = RL 37.920; modelled at RL 38.420
o Upper Floor FFL = RL 40.920; modelled at RL 41.420
The kitchen exhaust fan has been modelled as a single point source positioned 1.0 m above the
finished roof level, representing rooftop duct discharge. A conservative sound power level of 80
dBA was adopted for the assessment.
All air-conditioning units have been modelled assuming continuous (100%) operation to represent
a worst-case scenario. The kitchen exhaust fan has been assessed during daytime and evening
periods only, as operation of the shared kitchen is not proposed after 10:00 pm.
The pool pump has been modelled at a sound power level of 63 dBA at 0.3m height, based on
the manufacturer’s Pantera Pool Pumps Technical Data Sheet. We have been informed that the
pump operates on a 2 x 3 hour timer during the day.
Live It Acoustics Page 19
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
RFI - App E - Amended Noise Impact Assessment.pdfRelated documentApplication case desk ↗
About this file
- File size
- 8.6 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.