Council archive · source document
RFI - App E - Amended Noise Impact Assessment · 132008.299.02
RG Strategic #70250009-ENAC-RPT01-R3
Dolphin Backpackers – 14-16 Duke Street, Sunshine Beach 14 September 2026
Noise Impact Assessment
7 Recommendations
The development is expected to achieve compliance with the operational noise criteria, provided
the following recommendations are implemented.
7.1 Mechanical Plant
A preliminary screening assessment of mechanical plant noise has undertaken.
Noise modelling indicates that:
• The existing pool pump can be retained without the need for acoustic treatment, provided
its operation is restricted to daytime and evening hours only (7:00 am to 10:00 pm).
• Air-conditioning units located externally along the north-eastern façade (external to
dormitories) should be limited to a maximum cumulative outdoor sound power level of 67
dBA if installed without additional acoustic screening.
• Air-conditioning condenser units should be installed at ground level only, and should not
be wall mounted on the second storey façade. This is to mitigate direct line-of-sight
propagation to receptors.
• A roof-mounted kitchen exhaust fan system of typical specification is predicted to comply
with the established noise criteria without the need for further treatment. Before
installation, the final fan selection should be reviewed and confirmed by the acoustic
consultant.
Regardless of the final equipment selection or installation location, all mechanical plant must be
specified and designed to achieve compliance with the continuous noise criteria outlined in
Section 4.4 of this report. A detailed review of plant noise emissions by the project acoustic
consultant should be undertaken at the detailed design stage to verify compliance.
7.2 Management Controls
The following management controls should be implemented:
• Use of the BBQ outdoor terrace should be limited to daytime and evening hours only (7:00
am to 10:00 pm). From an acoustics perspective, the outdoor terrace adjoining the kitchen
may be used by guests at all times.
• Commercial deliveries should be restricted to daytime and evening periods only (7:00 am
to 10:00 pm).
Live It Acoustics Page 23
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
RFI - App E - Amended Noise Impact Assessment.pdfRelated documentApplication case desk ↗
About this file
- File size
- 8.6 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.