RG Strategic                                                             #70250009-ENAC-RPT01-R3
Dolphin Backpackers – 14-16 Duke Street, Sunshine Beach                          14 September 2026
Noise Impact Assessment


7 Recommendations
The development is expected to achieve compliance with the operational noise criteria, provided
the following recommendations are implemented.


7.1      Mechanical Plant
A preliminary screening assessment of mechanical plant noise has undertaken.

Noise modelling indicates that:

    •    The existing pool pump can be retained without the need for acoustic treatment, provided
         its operation is restricted to daytime and evening hours only (7:00 am to 10:00 pm).

    •    Air-conditioning units located externally along the north-eastern façade (external to
         dormitories) should be limited to a maximum cumulative outdoor sound power level of 67
         dBA if installed without additional acoustic screening.

    •    Air-conditioning condenser units should be installed at ground level only, and should not
         be wall mounted on the second storey façade. This is to mitigate direct line-of-sight
         propagation to receptors.

    •    A roof-mounted kitchen exhaust fan system of typical specification is predicted to comply
         with the established noise criteria without the need for further treatment. Before
         installation, the final fan selection should be reviewed and confirmed by the acoustic
         consultant.

Regardless of the final equipment selection or installation location, all mechanical plant must be
specified and designed to achieve compliance with the continuous noise criteria outlined in
Section 4.4 of this report. A detailed review of plant noise emissions by the project acoustic
consultant should be undertaken at the detailed design stage to verify compliance.


7.2      Management Controls
The following management controls should be implemented:

    •    Use of the BBQ outdoor terrace should be limited to daytime and evening hours only (7:00
         am to 10:00 pm). From an acoustics perspective, the outdoor terrace adjoining the kitchen
         may be used by guests at all times.
    •    Commercial deliveries should be restricted to daytime and evening periods only (7:00 am
         to 10:00 pm).




Live It Acoustics                                                                          Page 23

Used in these records

About this file

File size
8.6 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

RFI - App E - Amended Noise Impact Assessment.pdf · 8.6 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.