Skip to the record
NoosaWatch™: The source of truth.

Original source · versioned page text

MCU 16 0090 - Attachments

Attached to the e-mail Information Response - MCU 16/0090.

of 6

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

From:           Doug Reynolds
To:             Russell Green
Subject:        16520 - Sunshine Butterflies - response to Information Request
Date:           Friday, 14 October 2016 12:12:07 PM
Attachments:    image001.png
                image002.png
                image007.png
                image008.png
                BAR figure 4.9 Austroads Part 4A.pdf


Russell,



Item 2, 3 & 5 - As outlined in the Engineering report prepared by Tod Consulting the
traffic volumes only warrant the upgrade to a BAR turning treatment. Whilst this may be
the minimum standard it is also the appropriate standard for the number of vehicles
turning into the property during the peak hour. As noted in the report the traffic
generation is spilt between staff and clients and importantly it should be noted that
these traffic movements occur at different times. As such the peak hour turning volume
is expected to be 6 vehicles at full operation. Based on figure 4.9 in Austroads Part 4A
the appropriate treatment is clearly a BAR. Recent discussions with Main Roads staff
have confirmed that they will draft conditions approving this treatment and the use of a
second driveway for exit only use. We therefore disagree that higher standard is
necessary.

It is agreed that the accesses should be designed and constructed in accordance with
IPWEAQ standard drawing SEQ-R-56 which includes a bitumen seal from the road
edge to the property boundary. It is proposed to have unsealed pavements within the
site for parking and circulating as per the master plan. Given the low volumes of traffic
involved this is considered appropriate for the proposed use.

As noted above TMR have advised that they will issue their approval and conditions
shortly and this will include agreement to the BAR treatment, second driveway for exit
only use and that driveways are to be sealed to the property boundary. We will forward
a copy of this approval in due course.

Thanks and Regards
Doug Reynolds, Director – Civil Group, B.Eng (Civil), RPEQ, Member IPWEAQ, Member AIPM




0488 383 370 | [email protected]
Noosa: 07 5449 9600 Sunshine Coast: 07 5329 3190 Mackay: 07 4840 2337
TOD consulting pty ltd, PO Box 61, Noosaville QLD 4566




2016 State Award winner (Urban Design and Sustainable Architecture) – Noosa Bus Shelters
Log in to download the original file

MCU 16 0090 - Attachments.pdf · 1.6 MB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.