Council archive · source document
07/1992 - Op Works - Landscaping, carparking, access forntage works, stormwater & erosion & sediment control [As Published] · 142007.1992
_—
_—
_—
=
—
— 2
= = é
g 2 g
S — oa
a —
550 o/hang __ ——
‘ : 1800 o/hang —
_ — 600 of/hang
— I
ALUMINIUM FRAMED WINDOWS COLORBOND CUSTOM ORB TIMBER PURLINS AND RAFTERS TT
AND DOORS FIXED TO ROOF SHEETING TO MANUF. @ 900 CRS TO ENGINEERS —
MANUFACTURER'S SPEC AND SPEC FIXED TO N3 DESIGN AND DETAIL. ee —
N3 RATING NON-CYCLONIC RATING PBD LINING TO U/SIDE OF _— _——
HWD RAFTERS - SEALED AND RAFTERS —~ ——_ }<—_—_————_ HWD RAFTERS - COLORBOND CUSTOM ORB
PAINTED WHERE EXPOSED _— I SEALED AND PAINTED ROOF SHEETING TO MANUF.
| proH " NON-CYCLONIG RATING
— re GRANT STREET
So p>
_| YO INERT™ — 3 | et ae : = ee m, me “a Sey : - - -
| | UNIT 2 on Ss °RART 250mm GRATED DRAIN
DINING 7 CONCRETE
| i DRIVEWAY RL 24.678 fi. 24.728 RL 24.691 wa 20.564
K ul iif uf 1000mm GLAZED RL 24.558 °
| | | BALUSTRADE : ~~ KR SS 1
8 TIMBER FRAMED FLOORS WS? x ~~ SSS Sy XY Sy» SS y
SL
UPPER FLOOR @ RL 23.84 | | Ht S| || Tosxonesssos “s y a CRORE RSLS h ARK
“CEILING b— , PTITIILILIITITiTiiii ce C/N BRR S08 ORL.
His DPC UNDER TIMBER \
JOINERY | fonneue Crh ING —<. » » ” 190mm RC BLOCK RETAINING
~ | 7 LINING UNDER SLAB whe ay” \ R WALLS ‘AND FOOTINGS TO
- uw Ly » ENGINEERS DETAILS.
ve RC BLOCK WALL TO : AE YY AG. DRAINAGE PPE MIN, 100mm
| a ENGINEERS DESIGN : < Mee KS
: oe CRY RRR
| el Ae BED 2 eS eee SOY WYAYAS
2) ft. meme aa et es US
3 Bs MBER ERAME NC DPC TO MANUF. ——— Sin ITS Sy SUSPENDED RC SLAB TO
LOWER FLOOR @ RL 20.94 We vs SPECIFICATIONS —— VA Yi Keekhek ? ENGINEERS DESIGN AND
~ _ = F SV DETAIL
| ee “ oN *@ RL 20.89
RC SLAB, BLOCK RETAINING WALL
AND FOOTING TO ENGINEERS DESIGN
HWD TIMBER DECK WITH HWD
SHOTEDGE DECKING AS PER A DRAINAGE PIPE, MIN. 100mm
NEIGHBOUR FENCING . pea E 3 een wel = ° < 5
Le SRROKGRRREEREA
NGL AT SECTION , N YY, SSI6ON NPNYS 75 x 75 SHS POST
RR FOG Si 7 oH)
YI x -_
:
LS
KX SCA ee
FIRE RATED PARTITION WALL RC FOOTING STO ENGINEERS
TO MIN. FRL 60/60/60. DESIGN AND DETAIL.
SELECT CR FINISH
SECTION A-A - TYPICAL
SCALE 1:50
% Southern Cross
Design & Drafting
Commercial * Industrial * residenti
Suite/4 80 Sixth Ave Maroochydore
Ph: 5479 5313 Fax: 5479 5314
QBSA Lic 1110414
90 X 19mm SHOTEDGE HWD
TIMBER BATTENS BETWEEN
BLOCK WALLS
AMENDMENTS
27.08.07
19.09.07
Notes:
These drawings have been prepared for Building Permit application only. It is the Builders/owners responsibility
to further interpret the design and drawings to detail the project for construction.
Builder shall verify all locations of services, dimensions and levels prior to construction.
Setout dimensions on site shal) be confirmed 1" before commencement of construction and ordering.
Amend setout if necessary to comply with council by-laws and setback distances.
During construction the building shall ba maintained in a stable condition and no part shall ba overstressed.
CLIENT:
LOT NUMBER:
SUBURB:
PROJECT INFORMATION
PROJECT TYPE: RESIDENTIAL
Raised carport slab RL
& added 400mm step in slab.
Updated driveway profile
Moved Unit 800mm towards rear
boundary.
Raise Unit 200mm and lower
carport slab 172mm.
Updated driveway profile.
Changed truss roof to rafter
and puriins with raked ceiling.
Changed wall between Bed 2 &
Terrace from timber frame to
RC block.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/1992 - Op Works - Landscaping, carparking, access forntage works, stormwater & erosion & sediment control [As Published]Related documentApplication case desk ↗
About this file
- File size
- 3.1 MB (large file)
- File type
No other editions are linked here.
Original file