COLORBOND FASCIA AND
GUTTER. COLOUR 1

PITCH __ \
SOINERY.

 

 

Unit 2
4
RENDERED FC SHEETING FIXED TO

70mm TIMBER FRAME.
COLOUR 3

 

 

 

100 X 100 HWD TIMBER POSTS.

  
  
     

 

 
 

    

 

 

 

 

 

 

 

  

 
 

 
  

           
 

 
  

 
 

 
 

 

    

 

 

 

 

 

   
    

Hil * 90x 191mm SHOTEDGE HWD TIMBER
COLOUR S me | BATTEN 8CREEN. COLOUR 2
‘RET @BOURDAR H ‘ SUSPENDED RC SLAB TO
JOINERY
RC BLOCK WALLS WITH SELECT
OUTLINE OF 400mm HIGH RC CR FINISH. COLOUR 3
BLOCK RETAINING WALL.
REMOVED FOR CLARITY
LOWER FLOOR @ RL 20.94
TO MIN. FRL 60v8080, ‘AND DOORS FIXED TO
RC FOOTINGS AND BLOCK MANUFACTURER'S SPEC AND
WALL TO ENGINEERS DETAILS NS RATING
SCALE 1:100
. « 400
Unit 1 Unit 2 ee
COLORBOND CUSTOM ORB ROOF RENDERED FC SHEETING FIXED
SHEETING TO MANUF. SPEC FIXED. TO 70mm TIMBER FRAME.
TO N3 NON-CYCLONIC RATING. COLOUR 3
COLOUR 1
r nent ny SOLAR HOT WATER SYSTEM AS:
§ Hi i 4 ST PER BUILDER'S CONTRACT.
Le fe rl POSITION TO BE VERIFIED
i COLORBOND FASCIA AND:
PITCH 7 — GUTTER. COLOUR 1
JOINERY et Ie
}—— ALUMINIUM FRAMED WINDOWS
AND DOORS FIXED TO
MANUFACTURER'S SPEC AND
N3 RATING
UPPER FLOOR @ RL 23.84
CEILING -
JOINERY _
COLORBOND CUSTOM ORB
| CLADDING TO MANUF. SPEC FIXED
TO N3 NON-CYCLONIC RATING.
COLOUR 1

100 X 100 HWD TIMBER POSTS.
COLOUR 3

LOWER FLOOR @ RL 20.94

TIMBER FRAMED STAIRS WITH
SS WIRE BALUSTRADE

 

 

 

 

   

1000mm GLAZED
BALUSTRADE

FIRE RATED PARTITION WALL
TO MIN. FRL 60/60/60.
SELECT CR FINISH. COLOUR 3

ELEVATION C

SCALE 1:100

  

4 | Sheet roof, gutters |COLORBOND
& downpipes. "Windspray”
Custom Orb
cladding or equal colour

Timber batten DULUX
screens "Ferry"

or equal colour

Rendered sheeting] ny, yx

, walls & exposed | », L ”
timber ‘Clay Bake’

{truss tails, posts,
beams & battens)

or equat colour

 

 

Schedule of External Colours

 

 

 

  
 

Property Line

HWD RAFTERS AND BATTENS - SEALED AND
PAINTED WHERE EXPOSED. COLOUR 3

COLORBOND CUSTOM ORS ROOF
SHEETING TO MANUF. SPEC FIXED

|
GRANT STREET |

 

 

COLORBOND CUSTOM ORB ROOF
SHEETING TO MANUF. SPEC FIXED

TON3 NON-CYCLONIC RATING. “a P
COLOUR 1

RENDERED FC SHEETING FIXED TO
70mm TIMBER FRAME.

Property Line C)

   
    
 
    

ALUMINIUM FRAMED WINDOWS AND:
DOORS FIXED TO MANUFACTURER'S
SPEC AND N3 RATING

 

 

 

 

 

 

 

 

 

  
 

 

| TO N3 NON-CYCLONIG RATING, 8m ABOVE NGL

ne PITCH
— R 5 i SS JOINERY
COLORBOND FASCIA
2 8 AND GUTTER.

8
s $ COLOUR 1

nN N
_CARPORT SLAB @ RL SS _ ne UPPER FLOOR @ Rus a Be
RENDERED FC SHEET FIXED TO JOINERY.
70mm TIMBER FRAME, 100 X 100 HWD TIMBER
COLOUR 3 POSTS. COLOUR 3
TERRACE SLAB @ RL 20.89 LOWER FLOOR @ RL 20.94

RC BLOCK WALLS WITH SELECT CR
FINISH. COLOUR 3

90 x 19mm SHOTEDGE HWD TIMBER
BATTEN SCREEN. COLOUR 2

ELEVATION B

SCALE 1:100

    

 

 

 

 

 

a
=
5
- COLORBOND CUSTOM ORB ROOF
a SHEETING TO MANUF. SPEC FIXED
550 a 400
2 TO N3 NON-CYCLONIC RATING.
a COLOUR 1
ALUMINIUM FRAMED WINDOWS AND RENDERED FC SHEETING FIXED TO
DOORS FIXED TO MANUFACTURER'S 70mm TIMBER FRAME.
SPEC AND N3 RATING COLOUR 3
reprich
_
pocH
JOINERY a
COLORBOND FASCIA
AND GUTTER
COLOUR 14
UPPER FLOOR @ RL 23.84 -
CEILING
JOINERY
100 X 100 HWD TIMBER
POSTS. COLOUR 3
LOWER FLOOR @ RL 20.94 I _

 

BOUNDARY
FENCE

COLORBOND CUSTOM ORB
CLADDING TO MANUF. SPEC FIXED

90x 19mm SHOTEDGE HWD

TIMBER BATTEN SCREEN. TON3 NON-CYCLONIC RATING.

COLOUR 2 COLOUR 1

ELEVATION D

| SCALE 1:100

 

S Southern Cross
Design & Drafting

Commercial * Industrial * residenti.

Suite/4 80 Sixth Ave Maroochydore buliding designers’
Ph: 5479 5313 Fax: 5479 5314 association of
QBSA Lic 1110414 queensiand Inc.

Member

 

 
 
   
 
      
 
 

    
      
    
 
 
 
 
  
    
       
 

  
   

 

 

  

WINDOW SHAD!
HOODS. REFER BOUNDARY
DETAILS ON SHEET 7 FENCE

  

   

TIMBER FRAMED STAIRS WITH COLORBOND CUSTOM ORB
SS WIRE BALUSTRADE CLADDING TO MANUF. SPEC FIXED 90x 19mm SHOTEDGE HWD
TO N3 NON-CYCLONIC RATING. TIMBER BATTEN SCREEN.
COLOUR 1 oe
o
2
— >
—_ g
fi cy ae s
— a

\

—_— HWD RAFTERS AND BATTENS - SEALED AND
PAINTED WHERE EXPOSED. COLOUR 3

 

| GRANT STREET

TON3 NON-CYCLONIC RATING. |

COLORBOND CUSTOM ORB ROOF

COLOUR 1

 

 

70mm TIMBER FRAME.
COLOUR 3

 

TERRACE SLAB @ RL 20.89
RC BLOCK WALLS WITH SELECT CR
FINISH. COLOUR 3

90 x 19mm SHOTEDGE HWO TIMBER:
BATTEN SCREEN. COLOUR 2

WINDOW SHADE
HOODS. REFER
DETAILS ON SHEET 7

 

NOTES:

STAIRS TO COMPLY WITH BCA 3.9.1.3 AND 3.9.1.4
HANDRAILS AND BALUSTRADES TO

COMPLY WITH 3.9.2.3 (QLD)

(MIN 1000 HIGH AND 125 BETWEEN RAILS)

TIMBER FRAMED STAIRS WiTH
SS WIRE BALUSTRADE

ROOF WATER TO BE DISCHARGED TO
ON SITE WATER STORAGE TANKS

S PER HYDRAULIC ENGINEERS
BETAIS AND SPEC

N3

STRUCTURAL DESIGN BASED UPON
NON-CYCLONIC N3 FOR WIND SPEEDS

TO 41 mis.

AMENDMENTS
27.08.07 Raised carport slab RL
& added 400mm setp in slab
Updated driveway profile
LINTELS SPECIFIED REFER ENGINEERS
19.09.07 Moved Unit 800mm towards rear REPORT. ALL WET AREAS TO COMPLY

boundary. WITH B.C.A. 3.8.1 LINE U/SIDE OF
Raise Unit 200mm and lower EXTERNAL COVERED AREAS WITH F/C
carport slab 172mm. SHEETING.

Updated cveway Profile.
Add fixed glazing panel above

window to Dining. HATCHINGS AND FITTINGS ARE INDICATIVE

Changed truss roof on Upper level ONLY. REFER BUILDERS SPECIFICATION

to rafter & purlins with raked ceiling.

Changed wali between Bed 2 & TERMITE PROTECTION:

Terrace from timber frame to AS PER AUSTRALIAN STANDARDS AS3660.1/2000

RC block and changed door sizes.

These drawings have been prepared for Building Permit application only. It is the Builders/owners responsibility PROJECT TYPE: RESIDENTIAL

to further interpret the design and drawings to detail the project for construction
Builder shall verify all locations of services, dimensions and ‘evels prior to construction CLIENT: | Matthew & Joanne Exiey_|

Setout dimensions on site shail be Confirmed by builder before commencement of construction and ordering.

 

During construction the building shall be maintained in a stable condition and no part shall be overstressed.

LoTNuMBER; | 10 19/9/07
Amend setout if necessary to comply with council byiaws and setback distances. STREET: Scale: 4100 A1_ | 30f8

SUBURB:

 

 

 

 

Used in these records

About this file

File size
3.1 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

07_1992 - Op Works - Landscaping, carparking, access forntage works, stormwater & erosion & sediment control [As Published].pdf · 3.1 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.