68. Infrastructure including reticulated water, sewerage, stormwater, and electricity must be
protected from damage and made safe to the standard required by the regulatory authority.
69. Any damage to footpaths, street plantings, natural vegetation/trees, kerb and channel,
bridges or roadways at the removal/demolition site must be repaired or reinstated to at least
pre-existing conditions.
Plumbing and Drainage
70. It is a requirement of the ‘Standard Plumbing and Drainage Regulation 2019’ that at
demolition of a building, the existing sanitary drain upstream from the connection point for a
service provider’s sewerage system must be sealed water tight. This work is deemed as
notifiable Work and must be carried out by a suitably licenced plumber who must submit an
As Constructed plan and Form 4 (Notifiable Works Form) to the QBCC (Queensland Building
Construction Commission) within 10 days of completing the work.
4. CONSULTATION
4.1. Referral Agencies
Not applicable
4.2. Internal Council Referrals
Not applicable
5. CONCLUSION & REASONS FOR DECISION
The proposed development generally complies with the requirements of the planning scheme and
does not raise any significant issues that cannot be addressed by reasonable and relevant
conditions. The application is therefore recommended for approval.
The report is provided in accordance with Section 83(9) of the Planning Act 2016.
RECOMMENDATION
With regard to Application No. 51983.3225.22 to make a minor change to an existing approval for
Town Planning Consent 1632 – Multiple dwelling 25 Units, 8 shops and restaurant situated at The
Hastings 2/30 Hastings St Noosa Heads Qld 4567 and described as Lot 2 GTP 1154, Council on
19/05/2025 decided to:
A. Approve the change.
B. Amend Condition 2 to read as follows:
2. Development undertaken in accordance with this approval must generally comply with the
approved plans of development. The approved plans are listed in the following table unless
otherwise amended by these conditions.
Add the details of the submitted proposal plans to the approved plans table
Approved Plans – 19 May 2025 (Lot 2 on GTP1154) (51983.3225.22)
Plan No. Rev. Plan/Document Name Date
22048 C Site Plan prepared by GT Group Building Design 28.01.2025
A001
22048 C Demolition Floor Plan – Ground prepared by GT 28.01.2025
A051 Group Building Design
22048 D Demolition Floor Plan – Level 1 prepared by GT 28.01.2025
Group Building Design
A052
Page 14 of 17
Document Set ID: 23825275
Version: 0, Version Date: 01/01/1900
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Minor Change Report - 51983 3225 22 - Amended Report (As Published).pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.7 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.