Council archive · source document
OPW12/0139 Supporting documentaion for development application
.... ~
C.W. HENSTOCK & ASSOCIATES PTY. LTD.
~ ACN 003 416386
CONSULTING CIVIL, STRUCIVRAL & MARfl1ME ENGINEERS
ABN 44465206270
Our Ref: 2012/P044/CWH 2Sth July 2012
Waleon Marine Australia Pty Ltd
Horizon Shores Marina, Shed 04.7
Cabbage Tree Point Road,
WOONGOOLBA gLD 4207
Attn.: Mr. Andy Goss General ManQier-East
.
Dear Sirs,
Re: Proposed Lavout .Commercial Marina On Behalf: The Mcdonald Children’s Maintenance Trust -
Lot 162/CP907407 -186 Gvmple Terrace. Noosavllle
c. W. Henstock & Associates Pty Ltd has reviewed drawing No.’s UPL162.06.01 and UPL162.06.09 prepared by Ultracorp
Pty Ltd for the proposed commercial marina at the Game Fishing Wharf Boatshed, 186 Gympie Terrace, Noosaville, QLD.,
Lot 162/CP907407.
We confirm that the proposed marina layout is satisfactory in principle, for construction using Waleon Marine Australia
marine modules WSS (S Float) and PS8 (3Float) in the configurati n shown on the above drawings. The Waleon Marine
modules have been designed for compliance for the following design loads set out in Section 4 of AS3962-2001,
Australian Standards for the Guidelnes for the Design of Marinas:
a) Dead Load
b) Live Load
c) Environmental Loads
d) Loads from vessel wash.
e) Berthing and mooring loads.
The Waleon Marine pontoon units are approved in principle for use in this berthing facility for vessels ranging from 8
metre length to 10 metre as shown on the above drawings. The marina layout is a stabilised pontoon configuration and
the pontoons are adequate for the follOWing Floatation Live Load distribution.
1. Main Walkway -
3 KPa
2. Fingers -
2 KPa
The above approval in principle is subject to confirmation by a detailed design check should Walcon Marine be award
the Contract to supply and install the floating pontoon mar na modules.
It is our understanding that the cBent has obtained the relevant Development and Construction Approvals for the
project and that the design and suitability of the access ramp and the marina pontoon locating piles has been
undertaken by others.
Yours //
faithfU~IIY/.;
/)M~
---~
,1 _
c. W. Henstock,
CP.Eng., BSC Eng. (Civil), MBA (Tech. Mgt), FIE AUst., MICE, NPER (Civil & Structural), RPEQ No. 10155
C. W. Henstock & Associates Pty ltd.
Director.
.
I
Member of:
Suiles 1&2. PO Box 12-1 Telephone Facsimil~ [mail: ce\\ heJl5t bigpontl.ncLlI1I
~ 407 Hum~ Highway. f\!l>orebank N$\V 1875 61 2 9602 6398 61 1 9{)O I -102-1
’Xeb: \\\\\\’.1:\\ hen:iLlld:. OIl1.nll
CONSULT AUSTRALIA
:\lIslr~lia 61298225123
Li~erpl101 I\SW 2170
~
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
OPW12/0139 Supporting documentaion for development applicationRelated documentApplication case desk ↗
About this file
- File size
- 5.4 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.