Skip to the record
Accept no imitations.

Council archive · source document

App A Noise Assessment · MCU18/0102.02

of 37

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

Bounce Noosa, Noosaville                                                                                                      #1408d1-B
14 Mary St, Noosaville QLD 4566                                                                                    Date: 14 October 2022
Entertainment Noise Assessment


Appendix A – Calculation Summaries
Pre-6:00PM Assessment
           Table 1: Background LA90 noise level record and calculation sheet for amplified music and patron noise assessment - pre-6pm
           RAP.1 - 6 Ann St, NOOSAVILLE QLD 4566
 PRE
                   Measurement Details                  Wind        Noise                Octave band centre frequencies
 6PM                             Start                     Directio Descr-                                                           Overall
          Location Number                 Duration Speed                        63       125      250      500      1000    2000
                                 Time                          n     iptor
Row 1-1      L2        100 11:12AM 10 mins < 2m/s              E      L90    51 dBZ 44 dBZ 40 dBZ 39 dBZ 37 dBZ 35 dBZ 53 dBZ
Row 1-2    Minus insects/frogs (if applicable)                                0 dBZ     0 dBZ    0 dBZ    0 dBZ     0 dBZ   0 dBZ
Row 1-3    Plus non-standard windscreen attenuation (if applicable)           0 dBZ     0 dBZ    0 dBZ    0 dBZ     0 dBZ   0 dBZ
Row 1-4    'A' frequency weighting adjustment figures                          -26       -16       -9       -3        0        1
Row 1-6    Calculated LA90                                            L90    25 dBA 28 dBA 31 dBA 36 dBA 37 dBA 36 dBA 42 dBA
Row 1-7    Overall intrusive noise limit (LA90 + 10dBA)               L10                                                            52 dBA

         Table 2: Intrusive noise measurement data, normalisation & calculation of maximum noise limits to prevent unreasonable noise - pre-6pm
         Scenario 1 - RAP.1 - 6 Ann St, NOOSAVILLE QLD 4566
 PRE
                 Measurement Details                    Wind           Noise                Octave band centre frequencies
 6PM                            Start                       Directio Descr-                                                         Overall
        Location Number                Duration Speed                              63       125       250       500   1000  2000
                                Time                            n      iptor
Row 2-1 RAP1           \          \     3 mins < 2m/s           E       L10     83 dBZ 82 dBZ 72 dBZ 71 dBZ 67 dBZ 65 dBZ 86 dBZ
Row 2-2 Minus insects/frogs (if applicable)                                      0 dBZ     0 dBZ     0 dBZ    0 dBZ   0 dBZ 0 dBZ
Row 2-3 Plus non-standard windscreen attenuation (if applicable)                 0 dBZ     0 dBZ     0 dBZ    0 dBZ   0 dBZ 0 dBZ
Row 2-4 'A' frequency weighting adjustment figures                                -26       -16        -9        -3     0     1
Row 2-5 Calculated Intrusive noise level                                L10     57 dBA 66 dBA 63 dBA 68 dBA 67 dBA 66 dBA 73 dBA
Row 2-6    L1          3      10:39AM 3 mins < 2m/s             E       L10     84 dBZ 83 dBZ 74 dBZ 73 dBZ 68 dBZ 66 dBZ 87 dBZ
Row 2-7 Minus insects/frogs (if applicable)                                      0 dBZ     0 dBZ     0 dBZ    0 dBZ   0 dBZ 0 dBZ
Row 2-8 Plus non-standard windscreen attenuation (if applicable)                 0 dBZ     0 dBZ     0 dBZ    0 dBZ   0 dBZ 0 dBZ
Row 2-9 'A' frequency weighting adjustment figures                                -26       -16        -9        -3     0     1
Row 2-10 Calculated Intrusive noise level                               L10     58 dBA 67 dBA 65 dBA 70 dBA 68 dBA 67 dBA 75 dBA
Row 2-11 CEML1         2      10:35AM 3 mins < 2m/s             E       L10     88 dBZ 87 dBZ 84 dBZ 86 dBZ 79 dBZ 78 dBZ 93 dBZ
Row 2-12 Minus insects/frogs (if applicable)                                     0 dBZ     0 dBZ     0 dBZ    0 dBZ   0 dBZ 0 dBZ
Row 2-13 Plus non-standard windscreen attenuation (if applicable)                0 dBZ     0 dBZ     0 dBZ    0 dBZ   0 dBZ 0 dBZ
Row 2-14 'A' frequency weighting adjustment figures                               -26       -16        -9        -3     0     1
Row 2-15 Calculated Intrusive noise level                               L10     62 dBA 71 dBA 75 dBA 83 dBA 79 dBA 79 dBA 86 dBA
Row 2-16 SLPA1         1      10:30AM 3 mins < 2m/s             E       L10    103 dBZ 104 dBZ 104 dBZ 103 dBZ 99 dBZ 98 dBZ 110 dBZ
                  A-Weighted SLPA Source Measurement                    L10     77 dBA 88 dBA 95 dBA 100 dBA 99 dBA 99 dBA 105 dBA
Row 2-17 Normalisation Moderator                                               105 dBZ 109 dBZ 100 dBZ 99 dBZ 96 dBZ 95 dBZ 102 dBA
Row 2-18 Normalised Adj. (reference - measured levels) (Row 2-17 minus Row 2-16) 2 dBZ     5 dBZ    -4 dBZ -4 dBZ -3 dBZ -3 dBZ
Row 2-19 Normalised intrusive noise levels, L10, (Row 2-18 plus Row 2-1,L10 2-2 or
                                                                                85 2-3,
                                                                                    dBZ whichever
                                                                                          87 dBZ is 69
                                                                                                    applicable)
                                                                                                        dBZ 67 dBZ 64 dBZ 62 dBZ 89 dBZ
Row 2-20 'A' frequency weighting adjustment figures                               -26       -16        -9        -3     0     1
Row 2-21 'A' Weighted normalised intrusive noise level, L10             L10     59 dBA 71 dBA 60 dBA 64 dBA 64 dBA 63 dBA 73 dBA
Row 2-22 Noise character                                                                                                              16
Row 2-23 Adjusted intrusive noise level due to noise character                                                                      78 dBA
Row 2-24 Noise limit at affected premises (Row 1-7)                                                                                 52 dBA
Row 2-25 Difference between intrusive & noise limit at affected premises                                                            27 dBA
Row 2-26 Maximum noise level at Reference Point Location (RPL)                                                                      46 dBA
Row 2-27 Maximum noise level at Close External Monitoring Location (CEML)                                                           57 dBA
Row 2-28 Maximum noise level at specific licence area (Source)                                                                      75 dBA




Page 15 of 35 | Version 1.6 ▪ 19 April 2021                                                             Live It Acoustics | 1300 775 800

Used in these records

About this file

File size
2.3 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

App A Noise Assessment.pdf · 2.3 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.