Skip to the record
For the highest quality transcripts.

Council archive · source document

App A Noise Assessment · MCU18/0102.02

of 37

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

Bounce Noosa, Noosaville                                                                                                      #1408d1-B
14 Mary St, Noosaville QLD 4566                                                                                    Date: 14 October 2022
Entertainment Noise Assessment

           Table 1: Background LA90 noise level record and calculation sheet for amplified music and patron noise assessment - 6PM to 10PM
 6PM-      RAP.4 - 18 Mary St, NOOSAVILLE QLD 4566
                   Measurement Details                  Wind        Noise                Octave band centre frequencies
 10PM                            Start                     Directio Descr-                                                           Overall
          Location Number                 Duration Speed                        63       125      250      500      1000    2000
                                 Time                          n     iptor
Row 1-1      L5         12     9:55PM 10 mins < 2m/s          SE      L90    47 dBZ 46 dBZ 41 dBZ 42 dBZ 38 dBZ 34 dBZ 51 dBZ
Row 1-2    Minus insects/frogs (if applicable)                                0 dBZ     0 dBZ    0 dBZ    0 dBZ     0 dBZ   0 dBZ
Row 1-3    Plus non-standard windscreen attenuation (if applicable)           0 dBZ     0 dBZ    0 dBZ    0 dBZ     0 dBZ   0 dBZ
Row 1-4    'A' frequency weighting adjustment figures                          -26       -16       -9       -3        0        1
Row 1-6    Calculated LA90                                            L90    21 dBA 30 dBA 32 dBA 39 dBA 38 dBA 35 dBA 43 dBA
Row 1-7    Overall intrusive noise limit (LA90 + 10dBA)               L10                                                            53 dBA

         Table 2: Intrusive noise measurement data, normalisation & calculation of maximum noise limits to prevent unreasonable noise - 6PM to 10PM
 6PM-    Scenario 1 - RAP.4 - 18 Mary St, NOOSAVILLE QLD 4566
                 Measurement Details                    Wind           Noise                Octave band centre frequencies
 10PM                           Start                       Directio Descr-                                                         Overall
        Location Number                Duration Speed                              63       125       250       500   1000  2000
                                Time                            n      iptor
Row 2-1 RAP4           \          \     3 mins < 2m/s           E       L10     71 dBZ 72 dBZ 64 dBZ 65 dBZ 61 dBZ 58 dBZ 75 dBZ
Row 2-2 Minus insects/frogs (if applicable)                                      0 dBZ     0 dBZ     0 dBZ    0 dBZ   0 dBZ 0 dBZ
Row 2-3 Plus non-standard windscreen attenuation (if applicable)                 0 dBZ     0 dBZ     0 dBZ    0 dBZ   0 dBZ 0 dBZ
Row 2-4 'A' frequency weighting adjustment figures                                -26       -16        -9        -3     0     1
Row 2-5 Calculated Intrusive noise level                                L10     45 dBA 56 dBA 55 dBA 62 dBA 61 dBA 59 dBA 66 dBA
Row 2-6    L3          7      10:56AM 3 mins < 2m/s                     L10     72 dBZ 74 dBZ 66 dBZ 66 dBZ 62 dBZ 60 dBZ 77 dBZ
Row 2-7 Minus insects/frogs (if applicable)                                      0 dBZ     0 dBZ     0 dBZ    0 dBZ   0 dBZ 0 dBZ
Row 2-8 Plus non-standard windscreen attenuation (if applicable)                 0 dBZ     0 dBZ     0 dBZ    0 dBZ   0 dBZ 0 dBZ
Row 2-9 'A' frequency weighting adjustment figures                                -26       -16        -9        -3     0     1
Row 2-10 Calculated Intrusive noise level                               L10     46 dBA 58 dBA 57 dBA 63 dBA 62 dBA 61 dBA 68 dBA
Row 2-11 CEML3         6      10:52AM 3 mins < 2m/s             E       L10     90 dBZ 92 dBZ 89 dBZ 85 dBZ 77 dBZ 76 dBZ 96 dBZ
Row 2-12 Minus insects/frogs (if applicable)                                     0 dBZ     0 dBZ     0 dBZ    0 dBZ   0 dBZ 0 dBZ
Row 2-13 Plus non-standard windscreen attenuation (if applicable)                0 dBZ     0 dBZ     0 dBZ    0 dBZ   0 dBZ 0 dBZ
Row 2-14 'A' frequency weighting adjustment figures                               -26       -16        -9        -3     0     1
Row 2-15 Calculated Intrusive noise level                               L10     64 dBA 76 dBA 80 dBA 82 dBA 77 dBA 77 dBA 86 dBA
Row 2-16 SLPA1         1      10:30AM 3 mins < 2m/s             E       L10    103 dBZ 104 dBZ 104 dBZ 103 dBZ 99 dBZ 98 dBZ 110 dBZ
                  A-Weighted SLPA Source Measurement                    L10     77 dBA 88 dBA 95 dBA 100 dBA 99 dBA 99 dBA 105 dBA
Row 2-17 Normalisation Moderator                                               105 dBZ 109 dBZ 100 dBZ 99 dBZ 96 dBZ 95 dBZ 102 dBA
Row 2-18 Normalised Adj. (reference - measured levels) (Row 2-17 minus Row 2-16) 2 dBZ     5 dBZ    -4 dBZ -4 dBZ -3 dBZ -3 dBZ
Row 2-19 Normalised intrusive noise levels, L10, (Row 2-18 plus Row 2-1,L10 2-2 or
                                                                                73 2-3,
                                                                                    dBZ whichever
                                                                                          77 dBZ is 61
                                                                                                    applicable)
                                                                                                        dBZ 60 dBZ 58 dBZ 56 dBZ 78 dBZ
Row 2-20 'A' frequency weighting adjustment figures                               -26       -16        -9        -3     0     1
Row 2-21 'A' Weighted normalised intrusive noise level, L10             L10     47 dBA 61 dBA 52 dBA 57 dBA 58 dBA 57 dBA 65 dBA
Row 2-22 Noise character                                                                                                              14
Row 2-23 Adjusted intrusive noise level due to noise character                                                                      65 dBA
Row 2-24 Noise limit at affected premises (Row 1-7)                                                                                 53 dBA
Row 2-25 Difference between intrusive & noise limit at affected premises                                                            12 dBA
Row 2-26 Maximum noise level at Reference Point Location (RPL)                                                                      54 dBA
Row 2-27 Maximum noise level at Close External Monitoring Location (CEML)                                                           72 dBA
Row 2-28 Maximum noise level at specific licence area (Source)                                                                      90 dBA




Page 24 of 35 | Version 1.6 ▪ 19 April 2021                                                             Live It Acoustics | 1300 775 800

Used in these records

About this file

File size
2.3 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

App A Noise Assessment.pdf · 2.3 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.