Appendix F- Acousitc Report · MCU21/0117.01
Cooroy Villas Pty Ltd Environmental Traffic and Rail Noise Level Impact Assessment for Proposed Residential Unit Development, 54 Elm Street and 5 Pearl Street, Cooroy Page 7 of 36 a. Civil Engineering Standard Specification QR-CTS-Part41 – Part 41, Design and Construction of Noise Fences/Barriers, Queensland Rail 2018; b. Technical Specification MRTS15 Noise Fences, Transport and Main Roads, 2019; c. Technical Specification MRTS-4 General Earthworks, Transport and Main Roads, 2020. OR: AO41.2 Development achieves the maximum free field acoustic levels in reference table 2 (item 2.2) for private open space at the ground floor level by alternative noise attenuation measures where it is not practical to provide a noise barrier or earth mound. PO42 Development (excluding a relevant residential building or relocated building) minimises noise intrusion from a railway in habitable rooms at the facade of the ground floor level. AO42.1 Development (excluding a relevant residential building or relocated building) provides a noise barrier or earth mound which is designed, sited and constructed: 1. to achieve the maximum building facade acoustic level in reference table 1 (item 1.1) for habitable rooms at the ground floor level: 2. in accordance with: a. Civil Engineering Standard Specification QR-CTS-Part41 – Part 41, Design and Construction of Noise Fences/Barriers, Queensland Rail 2018; b. Technical Specification MRTS15 Noise Fences, Transport and Main Roads, 2019; c. Technical Specification MRTS-4 General Earthworks, Transport and Main Roads, 2020. OR: AO42.2 Development (excluding a relevant residential building or relocated building) achieves the maximum building facade acoustic levels in reference table 1 (item 1.1) for habitable rooms at the ground floor level by alternative noise attenuation measures where it is not practical to provide a noise barrier or earth mound. PO43 Habitable rooms (excluding a relevant residential building or relocated building) are designed and constructed using materials to achieve the maximum internal acoustic level in Table 3 (item 3.1). Above ground floor level requirements adjacent to a railway or Type 2 multi-modal corridor: PO44 Balconies, podiums and roof decks include: 1. a continuous solid gap-free structure or balustrade (excluding gaps required for drainage purposes to comply with the Building Code of Australia); 2. highly acoustically absorbent material treatment for the total area of the soffit above balconies, podiums and roof decks. PO45 Habitable rooms (excluding a relevant residential building or relocated building) are designed and constructed using materials to achieve the maximum internal acoustic level in Table 3 (item 3.1). The single event maximum sound level is the arithmetic average of the 15 highest train passby noise levels for a 24-hour period. Table 1, Item 1.1 states the following rail noise limits: David Moore & Associates Pty Ltd Our reference: R23089.docx/D3819/Rev.0/17.01.24
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix F- Acousitc Report.pdfRelated documentApplication case desk ↗
About this file
- File size
- 3.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.