Cooroy Villas Pty Ltd
Environmental Traffic and Rail Noise Level Impact Assessment for Proposed Residential Unit Development,
54 Elm Street and 5 Pearl Street, Cooroy                                                                     Page 9 of 36

PO40.1 Development (excluding a relevant residential building or relocated building) provides a noise
barrier or earth mound is provided which is designed, sited and constructed:

    1. to achieve the maximum building facade acoustic level in reference table 1 (item 1.1) for
       habitable rooms;

         In accordance with Table 1 the acoustic levels are:

              c) ≤60 dB(A) L10 (18 hour) façade corrected (measured L90 (8 hour) free field between
                 10pm and 6am ≤40 dB(A));

         OR

              d) ≤63 dB(A) L10 (18 hour) façade corrected (measured L90 (8 hour) free field between
                 10pm and 6am >40 dB(A))

    2. in accordance with:
           a. chapter 7 integrated noise barrier design of the Transport Noise Management Code of
               Practice: Volume 1 (Road Traffic Noise), Department of Transport and Main Roads,
               2013;
           b. Technical Specification-MRTS15 Noise Fences, Transport and Main Roads, 2019;
           c. Technical Specification-MRTS04 General Earthworks, Transport and Main Roads,
               2020;

         OR

AO40.2 Development (excluding a relevant residential building or relocated building) achieves the
maximum building facade acoustic level in reference table 1 (item 1.1) for habitable rooms by alternative
noise attenuation measures where it is not practical to provide a noise barrier or earth mound.

PO41 Habitable rooms (excluding a relevant residential building or relocated building) are designed
and constructed using materials to achieve the maximum internal acoustic level in reference table 3
(item 3.1).

In accordance with Table 3 the acoustic level is ≤35 dB(A) Leq (1 hour) (maximum over 24 hours).

NOTE: Facade correction is +2.5 dB(A) to the free field result.



Above ground floor level requirements (accommodation activity) adjacent to a state controlled
road

PO42 Balconies, podiums and roof decks include:
   1. A continuous solid gap-free structure or balustrade (excluding gaps required for drainage
      purposes to comply with the Building Code of Australia;
   2. Highly acoustically absorbent material treatment for the total area of the soffit above balconies,
      podiums, and roof decks.

PO43 Habitable room (excluding a relevant residential building or relocated building) are designed
and constructed using materials to achieve the maximum internal acoustic level in reference table 3
(item 3.1).

Additionally, habitable rooms within a transport noise corridor must comply with the Queensland
Development Code MP4.4, Buildings in a Transport Noise Corridor.




David Moore & Associates Pty Ltd                                          Our reference: R23089.docx/D3819/Rev.0/17.01.24

Used in these records

About this file

File size
3.0 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Appendix F- Acousitc Report.pdf · 3.0 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.