Council archive · source document
Appendix F- Acousitc Report · MCU21/0117.01
Cooroy Villas Pty Ltd Environmental Traffic and Rail Noise Level Impact Assessment for Proposed Residential Unit Development, 54 Elm Street and 5 Pearl Street, Cooroy Page 9 of 36 PO40.1 Development (excluding a relevant residential building or relocated building) provides a noise barrier or earth mound is provided which is designed, sited and constructed: 1. to achieve the maximum building facade acoustic level in reference table 1 (item 1.1) for habitable rooms; In accordance with Table 1 the acoustic levels are: c) ≤60 dB(A) L10 (18 hour) façade corrected (measured L90 (8 hour) free field between 10pm and 6am ≤40 dB(A)); OR d) ≤63 dB(A) L10 (18 hour) façade corrected (measured L90 (8 hour) free field between 10pm and 6am >40 dB(A)) 2. in accordance with: a. chapter 7 integrated noise barrier design of the Transport Noise Management Code of Practice: Volume 1 (Road Traffic Noise), Department of Transport and Main Roads, 2013; b. Technical Specification-MRTS15 Noise Fences, Transport and Main Roads, 2019; c. Technical Specification-MRTS04 General Earthworks, Transport and Main Roads, 2020; OR AO40.2 Development (excluding a relevant residential building or relocated building) achieves the maximum building facade acoustic level in reference table 1 (item 1.1) for habitable rooms by alternative noise attenuation measures where it is not practical to provide a noise barrier or earth mound. PO41 Habitable rooms (excluding a relevant residential building or relocated building) are designed and constructed using materials to achieve the maximum internal acoustic level in reference table 3 (item 3.1). In accordance with Table 3 the acoustic level is ≤35 dB(A) Leq (1 hour) (maximum over 24 hours). NOTE: Facade correction is +2.5 dB(A) to the free field result. Above ground floor level requirements (accommodation activity) adjacent to a state controlled road PO42 Balconies, podiums and roof decks include: 1. A continuous solid gap-free structure or balustrade (excluding gaps required for drainage purposes to comply with the Building Code of Australia; 2. Highly acoustically absorbent material treatment for the total area of the soffit above balconies, podiums, and roof decks. PO43 Habitable room (excluding a relevant residential building or relocated building) are designed and constructed using materials to achieve the maximum internal acoustic level in reference table 3 (item 3.1). Additionally, habitable rooms within a transport noise corridor must comply with the Queensland Development Code MP4.4, Buildings in a Transport Noise Corridor. David Moore & Associates Pty Ltd Our reference: R23089.docx/D3819/Rev.0/17.01.24
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix F- Acousitc Report.pdfRelated documentApplication case desk ↗
About this file
- File size
- 3.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.