Council archive · source document
Appendix F- Acousitc Report · MCU21/0117.01
Cooroy Villas Pty Ltd Environmental Traffic and Rail Noise Level Impact Assessment for Proposed Residential Unit Development, 54 Elm Street and 5 Pearl Street, Cooroy Page 13 of 36 Ground Floor Building Facade Noise Levels At monitoring location A the rail noise levels are, relative to the requirements of PO42: • 54.9 + 2.5 (facade correction) = 57.4 dB(A) LAeq,24h; and • 75.2 + 2.5 (facade correction) = 77.7 dB(A) single event maximum rail passby noise. The above monitoring location A rail noise levels comply with the noise limits of LAeq,24H 65 dB(A) and single event maximum rail passby noise limit of 87 dB(A), as required by PO42. The closest building facades to the railway line will be setback from the Elm Street boundary 6 metres, compared to the microphone which was set back 7.6 metres. This difference of 1.6 + 1 (distance that the noise limit applies from the facade) = 2.6 metres would account for an increase in rail noise level at the closest facade of approximately: • 0.6 dB(A) single event maximum; • 0.3 dB(A) LAeq,24H. These adjustments to the above rail noise levels will still result in compliance with the facade noise criteria. First Floor Balconies For this proposed development there are no proposed first floor external living areas and therefore PO44 is not applicable. First Floor Facades As for the ground floor the first floor facades of habitable rooms complies with the facade corrected noise limit criteria of LAeq,24H 65 dB(A) and single event maximum rail passby noise limit of 87 dB(A). TRAFFIC NOISE Measured Noise Levels For details of the measurement equipment, equipment settings, calibration, monitoring location and atmospheric conditions, refer Appendix A. Appendix B contains all of the detailed results of the noise level measurements. From Appendix B, the following noise levels should be noted for monitoring location A (microphone elevated 1.6 metres): Wednesday 2 June: • LA10,18h = 58.8 dB(A) • LA90,8h (10 pm to 6 am) = 29.1 dB(A) • LA90,18h (6 am to midnight) = 43.6 dB(A) Thursday 3 June: • LA10,18h = 60.2 dB(A) • LA90,8h (10 pm to 6 am) = 33.0 dB(A) • LA90,18h (6 am to midnight) = 45.8 dB(A) Average: • LA10,18h = 59.5 dB(A) • LA90,8h (10 pm to 6 am) = 31.1 dB(A) • LA90,18h (6 am to midnight) = 44.7 dB(A) David Moore & Associates Pty Ltd Our reference: R23089.docx/D3819/Rev.0/17.01.24
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix F- Acousitc Report.pdfRelated documentApplication case desk ↗
About this file
- File size
- 3.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.