Cooroy Villas Pty Ltd
Environmental Traffic and Rail Noise Level Impact Assessment for Proposed Residential Unit Development,
54 Elm Street and 5 Pearl Street, Cooroy                                                                    Page 21 of 36

    •    Category 2:          Glazing:        Rw 32 for glazing with up to and equal to 1.8m2;
                                              Rw 35 for glazing greater than 1.8m2;
                              External walls: Rw 41;
                              Roof:           Rw 38;
                              Floors:         Rw 45;
                              Entry Doors:    Rw 33.

With respect to the above the following examples of achieving the nominated minimum Rw values
should be noted (extracted from MP4.4):

    •    Noise Category 0:             no additional acoustic treatment required;

    •    Noise Category 1:
            o Glazing Rw 27:
                   ▪ minimum 4mm thick glass with full perimeter acoustically rated seals;
            o Glazing Rw 24:
                   ▪ minimum 4mm thick glass with standard weather seals;
            o external walls Rw 35:
                   ▪ single leaf of clay brick masonry at least 110mm thick with:
                   vi.        a row of at least 70mm x 35mm timber studs or 64mm steel studs at
                                        600mm centres, spaced at least 20mm from the masonry wall;
                              and
                       (ii)     One layer of plasterboard at least 10mm thick fixed to outside face of
                                studs
                       OR
                   ▪ minimum 6mm thick fibre cement sheeting or weatherboards or plank cladding
                       externally, minimum 90mm deep timber stud or 92mm metal stud, standard
                       plasterboard at least 13mm thick internally.
            o Roof Rw 35:
                   ▪ Concrete or terracotta tile or metal sheet roof with sarking, plasterboard ceiling
                       at least 10mm thick fixed to ceiling cavity.
            o Entry doors Rw 28:
                   ▪ fixed so as to overlap the frame or rebate of the frame, constructed of –

                       vii.           Wood, particleboard or blockboard not less than 33mm thick; or

                              (ii)     Compressed fibre reinforced sheeting not less than 9mm thick; or

                              (iii)    Other suitable material with a mass per unit area not less than
                                       24.4kg/m2; or

                              (iv)     Solid core timber door not less than 35mm thick fitted with full
                                       perimeter acoustically rated seals.

    •    Noise Category 2:
            o Glazing Rw 35:
                   ▪ minimum 10.38mm thick laminated glass, with full perimeter acoustically rated
                       seals
            o Glazing Rw 32:
                   ▪ minimum 6.38mm thick laminated glass with full perimeter acoustically rated
                       seals.
            o External walls Rw 41:
                   ▪ two leaves of clay brick masonry at least 110mm thick with cavity not less than
                       50mm between leaves
                       OR
                       Single leaf of clay brick masonry at last 110mm thick with:




David Moore & Associates Pty Ltd                                          Our reference: R23089.docx/D3819/Rev.0/17.01.24

Used in these records

About this file

File size
3.0 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Appendix F- Acousitc Report.pdf · 3.0 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.