Council archive · source document
Appendix F- Acousitc Report · MCU21/0117.01
Cooroy Villas Pty Ltd Environmental Traffic and Rail Noise Level Impact Assessment for Proposed Residential Unit Development, 54 Elm Street and 5 Pearl Street, Cooroy Page 23 of 36 By path difference calculation an acoustic barrier 2.0 metres high on the Elm Street boundary with a return along the northern boundary 1.8 metres high will reduce traffic noise levels by more than the above required values. Figure 6 details the location of these acoustic barriers. These acoustic barriers must be designed and constructed in accordance with MRTS 15. With respect to Figure 6 the notation for the corner of each Lot with an acoustic barrier and for each change in direction of a Lot boundary with an acoustic barrier, the numbers represent base of acoustic barrier/top of acoustic barrier RL AHD. 16m long, 1.8m high 108.2/106.4 108.8/107.0 109.0/107.0 18m long, 2.0m high 109.3/107.3 Figure 6 Location and Height and Length of Acoustic Barriers (Bold Red Lines) David Moore & Associates Pty Ltd Our reference: R23089.docx/D3819/Rev.0/17.01.24