Column 1
Specific Outcomes

a) provide flood free access to premises and flood
free habitable areas;

b) allow only minor, short term and infrequent
flooding of non-habitable areas;

c) ensure drainage does not adversely impact
upon other premises; and

d) ensure filling or excavation does not adversely
impact upon other premises by—

i. causing ponding of water on the site or
nearby land;

ii. increasing flooding, which adversely
affects the safety or use of any land
upstream and downstream, and

iii, adversely affecting the flow of water in
any overtand flow path.

Sloping sites and ridgelines

017 Development on sloping sites—

a) is responsive to the natural topography of the site
and minimises cut and fill;

b) does not visually dominate the hill slope or
interrupt the skyline;

c) is integrated with the natural site characteristics

 

Column 2

 
 

Probable Solutions {if code assessable)
building or structure, floor levels for habitable
rooms are not less than the specified minimum
floor levels;

AND

$16.2 Where Council infrastructure is available—
a) any drainage (from buildings and land) flows to
that infrastructure; and

b) the infrastructure has the capacity to accept
any additional loading.

AND

$16.3 For Residential Uses—

a) where slab on ground construction is used,
filling does not extend more than 1m beyond the
building footprint and access to car parking areas,
measured from the outer wails of the building ; or
b) the design consists of a suspended floor
construction; AND

$16.4 Car parking and maneuvering areas are
constructed at a level that permits the parking
area to drain from the site by gravity means,
without the need for mechanical pumping; or
$16.5 Basements for residential uses have flood
immunity above the Q100 where alternative
means to mechanical pumping are used to
achieve such immunity; or

$16.6 Basements for non-residential uses have
flood immunity above the Q100 that may be
achieved by means of mechanical pumping where
the mechanical feature is installed with adequate
holding tanks and an alternative back up power
source

$17.1 Buildings and associated access ways are
not constructed on land with a slope greater than
1 in 4 (25%); AND

$17.2 Buildings are of split level design that step
down the slope or have a suspended floor
construction; AND

 

Column 3
petey an iC Les

Complies - development able to drain to
existing infrastructure. A separate application
for Operational Works will be submitted in this
regard.

—_}

Complies - The building steps down the slope
from the Grant Street frontage and has a
suspended floor construction. Minimal cut and
fill is proposed as a result of this design. The
distance between the ground and the lowest
part of the floor is less than 3 metres.

 

 

01164 Tokovic - Noosa Heads Locality

a oh ee ED Ok ee

page 5

Used in these records

About this file

File size
4.7 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

09_1689 - Multiple Housing Type 2 Duplex [As Published].pdf · 4.7 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.