Original source · versioned page text
9.5.22 Bushfire Hazard Assessment Management Plan v2 - 60 Glenridge Drive COOROIBAH
Original PDF page 27, section 1. The text section number identifies this passage in the reader.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawnBushfire Hazard Assessment & Management Plan v2 NCES REF: J001001 Lot 47 on RP860577 – 60 Glenridge Drive, Cooroibah 6 AUSTRALIAN STANDARD 3959:2018 CONSTRUCTION OF BUILDINGS IN BUSHFIRE PRONE AREAS (AS 3959:2018) SETBACKS In general, the far northern and southern portions of the site are mapped within the Bushfire Hazard Overlay in the Noosa Plan 2020 (refer Plate 12) and SPP Bushfire Hazard Overlay Map (refer Plate 1). Plate 12 – Asset Protection Zones Building works within land which has been designated under a power of legislation as being subject, or likely to be subject, to bushfires triggers building design assessment under AS 3959:2018 (NCC 2019). The Standard provides minimum construction requirements for new habitable dwellings and habitable building alterations in designated Bushfire Prone Areas. The construction requirements are intended to improve the performance of buildings subjected to burning debris, radiant heat or flame contact. Building works in Designated Bushfire Prone Areas must be built to the Bushfire Attack Level (BAL) construction standard relevant to the building site as identified by the AS 3959:2018 methodology. Based on the setbacks provided, all future Class 1 buildings are anticipated to achieve a BAL 29 construction standard or lower. A specific BAL assessment will be required once building plans have been progressed given the BAL relies on an accurate understanding of the final footprint of the building within the individual building envelopes and is required to be assessed against the active iteration of the Standard at the time of assessment. In this instance it is noted that several of the proposed building envelopes are located outside of the mapped extent of both the Noosa Council and State Planning Policy designated Bushfire Prone Areas. Proposed building works located outside of these mapped areas are not required to be built to satisfy AS 3959. It is noted that mapping would be expected to be expanded across the majority of the site in the future once the extent of proposed revegetation works matures. © 2022 26
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLarge file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.