Combined Approved Plans MCU21-0020.01 & OPW21-0035.01 · MCU21/0020.01
Plans and drawings: the text below has words only, no drawings.
Very large file (24.0 MB): may take a few minutes to open.
Drawing Schedule
Sheet No. Sheet Name Revision Current Revision Date
CON COVER SHEET M 27/06/2022
CON.01 3D PERSPECTIVES M 27/06/2022
CON.001 3D PERSPECTIVES M 27/06/2022
GR
CON.02 3D PERSPECTIVES M 27/06/2022
CON.03 COVER NOTES M 27/06/2022
AN
CON.04 SITE PLAN M 27/06/2022
T
CON.05 FLOOR PLAN - LOWER LVL N 27/06/2022
ST
CON.06 FLOOR PLAN - GROUND LVL N 27/06/2022
CON.07 FLOOR PLAN - UPPER LVL N 27/06/2022
RE
CON.08 SETOUT - LOWER LEVEL J 27/06/2022
ET
CON.09 SETOUT - GROUND LEVEL J 27/06/2022
CON.10 SETOUT - UPPER LEVEL I 27/06/2022
CON.11 DIMENSION PLAN - LOWER LEVEL D 27/06/2022
CON.12 DIMENSION PLAN - GROUND LEVEL D 27/06/2022
CON.13 DIMENSION PLAN - UPPER LEVEL D 27/06/2022
CON.14 WALL TYPE PLAN - LOWER LEVEL D 27/06/2022
CON.15 WALL TYPE PLAN - GROUND LEVEL D 27/06/2022
CON.16 WALL TYPE PLAN - UPPER LEVEL D 27/06/2022
CON.17 RCP - LOWER LEVEL D 27/06/2022
CON.18 RCP - GROUND LEVEL D 27/06/2022
CON.19 RCP - UPPER LEVEL D 27/06/2022
CON.20 ROOF DRAINAGE PLAN N 27/06/2022
CON.21 DOOR & WINDOW PLAN N 27/06/2022
CON.23 ELECTRICAL PLAN - LOWER LEVEL D 27/06/2022
CON.24 ELECTRICAL PLAN - GROUND FLOOR E 27/06/2022
CON.25 ELECTRICAL PLAN - UPPER LEVEL E 27/06/2022
CON.26 LIGHTING PLAN - LOWER D 27/06/2022
CON.27 LIGHTING PLAN - GROUND E 27/06/2022
CON.28 LIGHTING PLAN - UPPER E 27/06/2022
CON.30 ELEVATIONS N 27/06/2022
CON.31 ELEVATIONS N 27/06/2022
CON.32 BUILDING SECTIONS N 27/06/2022
CON.33 BUILDING SECTIONS N 27/06/2022
CON.34 BUILDING SECTIONS E 27/06/2022
CON.35 BUILDING SECTIONS E 27/06/2022
CON.36 BUILDING SECTIONS E 27/06/2022
CON.40 KITCHEN DETAILS E 27/06/2022
CON.41 KITCHEN DETAILS E 27/06/2022
CON.45 ENSUITE DETAILS E 27/06/2022
CON.46 BATHROOM DETAILS E 27/06/2022
CON.47 LAUNDRY DETAILS D 27/06/2022
CON.50 INTERNAL STAIR DETAILS E 27/06/2022
CON.51 EXTERNAL STAIR DETAILS E 27/06/2022
CON.075 TYPICAL FRAMING DETAILS E 27/06/2022
CON.076 CONSTRUCTION DETAILS F 27/06/2022
CON.077 CONSTRUCTION DETAILS D 27/06/2022
INDICATES BUILDING FOOTPRINT CON.078 CONSTRUCTION DETAILS D 27/06/2022
AT GROUND (MID) LEVEL
CON.079 PRIVACY SCREEN DETAILS E 27/06/2022
CON.080 PRIVACY SCREEN DETAILS E 27/06/2022
CON.081 BATTEN SCREEN DETAILS D 27/06/2022
CON.082 POOL DETAIL N 27/06/2022
CON.083 STRATA + SERVICES B 27/06/2022
Plan CON.090 STRUCTURAL GENERAL NOTES L 27/06/2022
1 : 200 CON.091 BAL GENERAL NOTES B 27/06/2022
SITE PLAN - Proposed
CON.092 BAL GENERAL NOTES B 27/06/2022
- CON.093 RFI - HEIGHTS BLANKET DIAGRAM G 27/06/2022
NOOSA COUNCIL CON.094 RFI - SIGHT LINES G 27/06/2022
APPROVED PLAN CON.095 RFI - SUSPENDED ENTRY PATH H 27/06/2022
MCU21/0020.01 & OPW21/0035.01
16 NOV 2022
No. Description Date
I Approval Issue J 18/08/2021 Project number Scale at A3
Project Client Drawing Drawn by
dennishillarchitect 27 Grant Street, Brown Rooster Pty SITE PLAN DRH
J
K
Construction Issue A
Construction Issue B
08/10/2021
28/10/2021
049 1 : 200
mobile: 0438 20 55 66 | [email protected] Noosa Heads Ltd
www.dennishillarchitect.com
L
M
Construction Issue C
Construction Issue D
11/03/2022
27/06/2022 CON.04
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 27/06/2022 4:54:41 PM
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of pages 2 to 15 (of 20)
Page 2
fence g w all
paling retainin
line of sl
1500 4.5m (h
)
tback to LVR
1.5m se LVR
2000
a
7m (h )
undercroft / se
b ov e r
ack to
2. 0m setb
retaining w all
4500
setback to rear boundary ens
WIR bed 2
FROSTED
LVR
paling fence
rvices
6000
setback to rear boundary
yard bthrm
FIXE D GLASS
robe
master media
suite
/60)
LIGHT-W ELL OVE
R
N WALL (60/60
FIRE SEPARATIO
R
LIGHT-W ELL OVE
paling fence
robe
undercroft / se
media
retaining wall
master
line of slab ov er
FIXE D GLASS
suite bthrm
bed 2
ices rv
yard
paling fence
FROSTED
WIR
LVR
ens
LVR LVR
2.0m setback to 7m (h)
1.5m setback to 4.5m (h) retaining wall
2000
1500
paling fence
GFA = 60.2sqm per unit GFA = 120.4sqm total
Plan
Lower Level 1 : 100
-
NOOSA COUNCIL
APPROVED PLAN
MCU21/0020.01 & OPW21/0035.01
16 NOV 2022
No. Description Date
J Construction Issue A 08/10/2021 Project number Scale at A3
Project Client Drawing Drawn by
dennishillarchitect 27 Grant Street, Brown Rooster Pty FLOOR PLAN - DRH
K
L
Construction Issue B
Construction Issue C
28/10/2021
11/03/2022
049 1 : 100
mobile: 0438 20 55 66 | [email protected] Noosa Heads Ltd LOWER LVL
www.dennishillarchitect.com
M
N
Construction Issue D
Construction Issue D
27/06/2022
27/06/2022 CON.05
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 27/06/2022 4:54:42 PM
Page 3
BINS
GRANT STREET
ffit over ppers
Letterbox
line o f so one ste
cy scre
en large st
batte ne
d priv a timber
deck
footpath
grated
entry
1500
ldry
DN
2000
tren
c h drain
4.5m (h
) PTRY UP
tback to DN
PTRY
WM
1.5m se
7m (h )
kitchen
S
tback to OPERABLE CAS
EMENT SHUTTER
2.0m se
living
DRY
STACKING DOO
garage
BULKHEAD OV
OV UNDER
6000
R
DW
BULKHEAD OV
setback to rear boundary
4500 e from rooftop
setback to rear boundary storage NOTE: downpip
FR
ER
6000
4000
5000
driveway
ER
DN N WALL (60 /60/60)
FIRE SEPARATIO
VOID
LIGHT-WELL /
BUILT-IN 6000
CABINETRY
LIGHT-W ELL /
VOID DN setback to front boundary
BUILT-IN
CABINETRY
BULKHEAD OV
grated tren ch
storage
FR
BULKHEAD OV garage
ER
drain
OV UNDER
kitchen
DW
line of roo f ove
DRY
ER
footpath
WM
STACKING DOO
PTRY
DN UP
ldry
Letterbox
r
living PTRY
R
DN
OPERABLE CAS
EMENT SHUTTER
S
LANDING entry
timber
large stone steppers
2.0m setback to 7m (h) deck
1.5m setback to 4.5m (h)
2000
handrail line of soffit over
BINS
1500
1500
GFA = 39.7sqm per unit GFA = 79.4sqm total
Plan
Ground Floor Plan 1 : 100
-
NOOSA COUNCIL
APPROVED PLAN
MCU21/0020.01 & OPW21/0035.01
16 NOV 2022
No. Description Date
J Construction Issue A 08/10/2021 Project number Scale at A3
Project Client Drawing Drawn by
dennishillarchitect 27 Grant Street, Brown Rooster Pty FLOOR PLAN - DRH
K
L
Construction Issue B
Construction Issue C
28/10/2021
11/03/2022
049 1 : 100
mobile: 0438 20 55 66 | [email protected] Noosa Heads Ltd GROUND LVL
www.dennishillarchitect.com
M
N
Construction Issue D
Construction Issue D
27/06/2022
27/06/2022 CON.06
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 27/06/2022 4:54:54 PM
Page 4
footpath
R
PLANTE
ENING
Y SC RE
PR IVAC
pool
bbq
pool
ST
pump PRE CA
ELL
POOL SH
PLANTE
rooftop
R
deck
OVER
LINE OF ROOF
N WALL (60 /60/60)
VELUX SKYLIGHTS FIRE SEPARATIO
rooftop
deck
PLANTER
OVER
LINE OF ROOF
3
CON.082
footpath
pool
PRECAST
pool POOL SHELL
pump bbq
PRIVACY SCREENING
Plan
Upper Level 1 : 100
-
NOOSA COUNCIL
APPROVED PLAN
MCU21/0020.01 & OPW21/0035.01
16 NOV 2022
No. Description Date
J Construction Issue A 08/10/2021 Project number Scale at A3
Project Client Drawing Drawn by
dennishillarchitect 27 Grant Street, Brown Rooster Pty FLOOR PLAN - DRH
K
L
Construction Issue B
Construction Issue C
28/10/2021
11/03/2022
049 1 : 100
mobile: 0438 20 55 66 | [email protected] Noosa Heads Ltd UPPER LVL
www.dennishillarchitect.com
M
N
Construction Issue D
Construction Issue D
27/06/2022
27/06/2022 CON.07
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 27/06/2022 4:54:57 PM
Page 5
Plan
ROOF DRAINAGE PLAN 1 : 100
rooftop
deck
DP
DP
PARAPET BEAM
LINE OF BUILD
land Grey
Colorbond Wood
RENDE
nt
Roof Catchme
PARAPE
RED BO
2.0°
INSULSPAN SIP ROOFING
= 139 sqm Colorbond Woodland Grey
ING UNDER
T
8.0°
XED
/60)
W-32 N WALL (60/60
W-31 FIRE SEPARATIO
W-29 W-30
INSULSPAN SIP ROOFING
Colorbond Woodland Grey
DP
DP
W-34 W-35 W-36 Roof Catchment
W-33 2.0°
= 19 sqm
LINE OF BUILD
rooftop
deck
ING UNDER
DP DP
Site Cover = 241sqm = 44%
DRAINAGE
NOTES:
Based on assumed 5 minute rainfall intensity - • Effective roof catchment area 158m² Downpipes are to be located where they will Downpipes are to service 12m maximum
All work to conform with Part MP 4.2 of the 189mm/h 20 years recurrence interval. • Roof catchment per downpipe 60m² not create a hazard to building users nor gutter length & be within 1.2m from each
Queensland Development Code (QDC) • Downpipes must not serve more than impede window & door openings and the valley unless overflow is provided for (NCC
(Water Saving Targets). Gutters & downpipes shall be in accordance 12m of gutter length for each downpipe like. They are to be installed as close as Vol2 P3.5.2.5)
with AS/NZS3500.5 domestic & Part 3.5.2, Vol 2 • Total rainfall intensity 158m² X 189mm/60 practicable to the supporting structure while
Roof stormwater is to discharge to local of the NCC. = 497.7L/min maintaining termite inspection clearances of
government requirements and approval. • Stormwater pipes - 100 dia. Laid at 1 in 25mm. Downpipes are to be protected from
Tank/s overflow and downpipes not All downpipes to be 90mm/100mm U-PVC. 100 minimum grade. potential mechanical damage, be installed -
connected to rainwater tank/s to discharge All gutters to be 150 Quad Gutters (8600mm² no less than 100mm from electrical cables & NOOSA COUNCIL
to interallotment drainage system/ to Cross section area). gas pipes & no less than 50mm from other APPROVED PLAN
nominated discharge points via bubbler Falls to be in accordance with clause 3.5.2.4, services (AS3500.3.2 S4.11)
system/ to discharge to street channel system. Vol 2 of the NCC.
MCU21/0020.01 & OPW21/0035.01
16 NOV 2022
No. Description Date
J Construction Issue A 08/10/2021 Project number Scale at A3
Project Client Drawing Drawn by
dennishillarchitect 27 Grant Street, Brown Rooster Pty ROOF DRAINAGE DRH
K
L
Construction Issue B
Construction Issue C
28/10/2021
11/03/2022
049 1 : 100
mobile: 0438 20 55 66 | [email protected] Noosa Heads Ltd PLAN
www.dennishillarchitect.com
M
N
Construction Issue D
Construction Issue D
27/06/2022
27/06/2022 CON.20
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 27/06/2022 4:55:13 PM
Page 6
6000 23210 4500
8m m
rear setback
ax im
boundary
front setback
um h
eigh 'Knotwood' timber- Raw/sealed FC
t
Raw polished concrete-look look aluminium sheeting with
190 series blockwork with render finish to mimic tilt- battens in colour matching cover-
stone cladding panels' 'Driftwood' strips at 450mm
centres
Rooftop Level
RL 23.784 m
boundary
Velux Hardies Axon Metal roofing, fascias,
Skylights Cladding in barges and gutters in
2700
colour Dulux Colorbond Basalt
'Basalt'
5200 Upper Level
RL 21.084 m
2700
Painted hardwood
4466
casement shutters
as detailed in
colour Dulux Garage Level
RL 18.384 m
620
'Shale Grey'
Ground Floor Level
RL 17.764 m
Raw polished concrete-look
render finish to mimic tilt-panels'
1 Elevation
3100
'Knotwood' timber-look Corefilled blockwork - standard
1 : 100 aluminium battens and cement render finish in colour
Elevation NW Dulux 'Basalt'
portal frames in colour
'Driftwood' Hardwood deck and stair
Corefilled blockwork - standard
cement render finish in colour Lower Level
Dulux 'Monument' RL 14.664 m
190 series blockwork with
selected render finish
Timber paling fence
Knotwood timber- Raw polished concrete-
look aluminium look render finish to
batten privacy Insulspan roofing mimic tilt-panels'
screens in clour in Colorbond
'Driftwood' 'Monument'
Raw polished concrete-
Corefilled blockwork - standard
look render finish to
cement render finish in colour
mimic tilt-panels'
Dulux 'Monument'
Knotwood timber-look
suspended conc. planter - aluminium batten privacy
standard cement render finish screens in clour 'Driftwood'
in colour Dulux 'Monument'
Upper Level
RL 21.084 m
Corefilled blockwork - standard
cement render finish in colour 'Knotwood' timber-look
Dulux 'Monument' aluminium battens and
portal frames in colour
powdercoated metal balustrade 'Driftwood'
in colour Dulux 'Monument'
Garage Level
RL 18.384 m
-
Knotwood timber-look aluminium Selected finish to tilt Raw polished concrete-
battens in clour 'Driftwood' to tilt Raw polished concrete- panel garage door to look render finish to NOOSA COUNCIL
panel garage door look render finish to match polished mimic tilt-panels' APPROVED PLAN
mimic tilt-panels' concrete MCU21/0020.01 & OPW21/0035.01
2 Elevation 16 NOV 2022
Elevation NE 1 : 100
No. Description Date
J Construction Issue A 08/10/2021 Project number Scale at A3
Project Client Drawing Drawn by
dennishillarchitect 27 Grant Street, Brown Rooster Pty ELEVATIONS DRH
K
L
Construction Issue B
Construction Issue C
28/10/2021
11/03/2022
049 1 : 100
mobile: 0438 20 55 66 | [email protected] Noosa Heads Ltd
www.dennishillarchitect.com
M
N
Construction Issue D
Construction Issue D
27/06/2022
27/06/2022 CON.30
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 27/06/2022 4:55:25 PM
Page 7
'Knotwood' timber- Corefilled blockwork - standard
look aluminium cement render finish in colour
battens in colour Dulux 'Monument' 190 series blockwork with
Raw/sealed FC 'Driftwood' stone cladding
sheeting with
Rooftop Level matching cover-
RL 23.784 m strips at 450mm
Metal roofing, fascias, barges and Hardies Axon Velux centres
gutters in Colorbond Basalt Cladding in Skylights
colour Dulux
'Basalt'
Upper Level
RL 21.084 m
6740
um height
8m maxim
Painted hardwood casement
shutters as detailed in colour
Dulux 'Shale Grey'
Garage Level Powdercoated
4300
RL 18.384 m steel balustrade in
Ground Floor Level colour 'Monument'
RL 17.764 m
Corefilled blockwork - standard cement
render finish in colour Dulux 'Basalt'
Raw polished concrete-look Powdercoated
render finish to mimic tilt-panels' steel balustrade in
Corefilled blockwork - standard colour 'Monument'
Hardwood deck and stair
cement render finish in colour
Lower Level Dulux 'Monument'
RL 14.664 m
Metal roofing, fascias, barges and Velux Skylights Corefilled blockwork - standard
gutters in Colorbond Basalt cement render finish in colour
Timber paling fence Corefilled blockwork - standard Dulux 'Monument'
cement render finish in colour
Dulux 'Monument'
Rooftop Level
RL 23.784 m
2 Elevation
Elevation SE 1 : 100
Upper Level
RL 21.084 m
190 series blockwork with
selected stone finish
Hardies Axon Cladding
Garage Level
RL 18.384 m
Ground Floor Level
RL 17.764 m
Hardies Axon Cladding
in colour Dulux 'Basalt'
Lower Level
RL 14.664 m
Corefilled blockwork -
- standard cement render finish
NOOSA COUNCIL in colour Dulux 'Monument'
APPROVED PLAN
MCU21/0020.01 & OPW21/0035.01 1 Elevation Hardwood deck and stair
16 NOV 2022 Elevation SW 1 : 100
No. Description Date
J Construction Issue A 08/10/2021 Project number Scale at A3
Project Client Drawing Drawn by
dennishillarchitect 27 Grant Street, Brown Rooster Pty ELEVATIONS DRH
K
L
Construction Issue B
Construction Issue C
28/10/2021
11/03/2022
049 1 : 100
mobile: 0438 20 55 66 | [email protected] Noosa Heads Ltd
www.dennishillarchitect.com
M
N
Construction Issue D
Construction Issue D
27/06/2022
27/06/2022 CON.31
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 27/06/2022 4:55:32 PM
Page 8
2 1 1 2
CON.34 CON.34CON.36 CON.36
3
CON.35
FIRE SEP WALL CONTINUES TO UNDERSIDE OF ROOF SHEET
Rooftop Level
RL 23.784 m
2
Raftered roof to engineers CON.35
specification
rooftop Suspended slab to engineers
Precast Pool details
Upper Level
RL 21.084 m
height
8m maximum
1
CON.35
garage
balc. living kitchen
Garage Level
RL 18.384 m
Ground Floor Level
RL 17.764 m
Suspended concrete floor to Driveway slab and footings to
undercroft engineers details
engineers specification
Corefilled blockwork columns
ens WIR media bed 2 to engineers specification
Timber paling fence
Lower Level
RL 14.664 m
Blockwork wall and retaining
compact fill to engineers details
Concrete slab and footings
to engineers details
UNITS 1 & 2 = MIRROR/TYPICAL
1 Section
CON.09 Section - A 1 : 100
-
NOOSA COUNCIL
APPROVED PLAN
MCU21/0020.01 & OPW21/0035.01
16 NOV 2022
No. Description Date
J Construction Issue A 08/10/2021 Project number Scale at A3
Project Client Drawing Drawn by
dennishillarchitect 27 Grant Street, Brown Rooster Pty BUILDING DRH
K
L
Construction Issue B
Construction Issue C
28/10/2021
11/03/2022
049 1 : 100
mobile: 0438 20 55 66 | [email protected] Noosa Heads Ltd SECTIONS
www.dennishillarchitect.com
M
N
Construction Issue D
Construction Issue D
27/06/2022
27/06/2022 CON.32
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 27/06/2022 4:55:34 PM
Page 9
Rooftop Level
FIRE SEP WALL CONTINUES TO UNDERSIDE OF ROOF SHEET RL 23.784 m
Raftered roof to engineers
specification
rooftop Suspended slab to engineers
details
Upper Level
RL 21.084 m
height
8m maximum
kitchen garage
Garage Level
RL 18.384 m
light well Ground Floor Level
RL 17.764 m
Suspended concrete floors Driveway slab and footings to
to engineers specification engineers details
hallway undercroft
Timber paling fence
Lower Level
RL 14.664 m
Blockwork wall and retaining
compact fill to engineers details
Concrete slab and footings
to engineers details
1 Section UNITS 1 & 2 = MIRROR/TYPICAL
CON.09 Section - B 1 : 100
-
NOOSA COUNCIL
APPROVED PLAN
MCU21/0020.01 & OPW21/0035.01
16 NOV 2022
No. Description Date
J Construction Issue A 08/10/2021 Project number Scale at A3
Project Client Drawing Drawn by
dennishillarchitect 27 Grant Street, Brown Rooster Pty BUILDING DRH
K
L
Construction Issue B
Construction Issue C
28/10/2021
11/03/2022
049 1 : 100
mobile: 0438 20 55 66 | [email protected] Noosa Heads Ltd SECTIONS
www.dennishillarchitect.com
M
N
Construction Issue D
Construction Issue D
27/06/2022
27/06/2022 CON.33
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 27/06/2022 4:55:35 PM
Page 10
190
260
260
260
260
260
2120
POOL
260
940
BBQ
190190
1000 190 2120 190
Plan
PLAN VIEW - POOL DETAIL 1 : 50
Illustration
POOL DETAIL
1 4
CON.082 CON.082 SIP roofing
glass stair precast concrete pool timber-look aluminium beam
balustrade Rendered finish
timber-look aluminium batten
precast pool shell privacy screen
landscape planter Blockwork wall shallow landscape planter
980
pool Rendered finish
pool
420
300
Upper Level Upper Level
RL 21.084 m RL 21.084 m
garage under
-
4 Section 1 Section NOOSA COUNCIL
CON.082 POOL SECTION A 1 : 50 CON.082 POOL SECTION B 1 : 50 APPROVED PLAN
MCU21/0020.01 & OPW21/0035.01
16 NOV 2022
No. Description Date
J Construction Issue A 08/10/2021 Project number Scale at A3
Project Client Drawing Drawn by
dennishillarchitect 27 Grant Street, Brown Rooster Pty POOL DETAIL DRH
K
L
Construction Issue B
Construction Issue C
28/10/2021
11/03/2022
049 1 : 50
mobile: 0438 20 55 66 | [email protected] Noosa Heads Ltd
www.dennishillarchitect.com
M
N
Construction Issue D
Construction Issue D
27/06/2022
27/06/2022 CON.082
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 27/06/2022 4:55:54 PM
Page 11
3D Topography duplicated to 8m
8000
above natural ground confirms
that no part of the proposed
building encroaches above the
8m maximum height limit
-
NOOSA COUNCIL
APPROVED PLAN
MCU21/0020.01 & OPW21/0035.01
16 NOV 2022
No. Description Date
C Approval Issue I 27/07/2021 Project number Scale at A3
Project Client Drawing Drawn by
dennishillarchitect 27 Grant Street, Brown Rooster Pty RFI - HEIGHTS DRH
D
E
Approval Issue J
Construction Issue B
18/08/2021
28/10/2021
049
mobile: 0438 20 55 66 | [email protected] Noosa Heads Ltd BLANKET
www.dennishillarchitect.com
DIAGRAM
F
G
Construction Issue C
Construction Issue D
11/03/2022
27/06/2022 CON.093
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 27/06/2022 4:55:57 PM
Page 12
Core-filled
blockwork wall
Rooftop Terrace
Powdercoated steel portal posts
Upper Level
Extent of privacy screening towards neighbouring dwelling RL 21.084 m
Upper level suspended
concrete slab
timber-look aluminium
batten screening
Core-filled blockwork wall Garage
Entry
Path
Suspended concrete entry path
Timber paling boundary fence
Garage Level
RL 18.384 m
Core-filled blockwork wall
1500
Undercroft
timber-look aluminium
batten privacy screen
1900mm high from FFL
2 Section
Suspended Entry Path Section 1 : 50
-
NOOSA COUNCIL
Illustration APPROVED PLAN
Entry Path Detail MCU21/0020.01 & OPW21/0035.01
16 NOV 2022
No. Description Date
D Approval Issue J 18/08/2021 Project number Scale at A3
Project Client Drawing Drawn by
dennishillarchitect 27 Grant Street, Brown Rooster Pty RFI - SUSPENDED DRH
E
F
Construction Issue B
Construction Issue C
28/10/2021
11/03/2022
049 1 : 50
mobile: 0438 20 55 66 | [email protected] Noosa Heads Ltd ENTRY PATH
www.dennishillarchitect.com
G
H
Construction Issue D
Construction Issue D
27/06/2022
27/06/2022 CON.095
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 27/06/2022 4:56:01 PM
Page 13
Front facade Rooftop Terrace
-
NOOSA COUNCIL
North-west Elevation APPROVED PLAN South-east Elevation
MCU21/0020.01 & OPW21/0035.01
16 NOV 2022
No. Description Date
I Approval Issue J 18/08/2021 Project number Scale at A3
Project Client Drawing Drawn by
dennishillarchitect 27 Grant Street, Brown Rooster Pty 3D PERSPECTIVES DRH
J
K
Construction Issue A
Construction Issue B
08/10/2021
28/10/2021
049
mobile: 0438 20 55 66 | [email protected] Noosa Heads Ltd
www.dennishillarchitect.com
L
M
Construction Issue C
Construction Issue D
11/03/2022
27/06/2022 CON.01
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 27/06/2022 4:54:36 PM
Page 14
Front facade Front facade
-
NOOSA COUNCIL
Entry - Unit a APPROVED PLAN Entry - Unit b
MCU21/0020.01 & OPW21/0035.01
16 NOV 2022
No. Description Date
I Approval Issue J 18/08/2021 Project number Scale at A3
Project Client Drawing Drawn by
dennishillarchitect 27 Grant Street, Brown Rooster Pty 3D PERSPECTIVES DRH
J
K
Construction Issue A
Construction Issue B
08/10/2021
28/10/2021
049
mobile: 0438 20 55 66 | [email protected] Noosa Heads Ltd
www.dennishillarchitect.com
L
M
Construction Issue C
Construction Issue D
11/03/2022
27/06/2022 CON.001
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 27/06/2022 4:54:36 PM
Page 15
Rear facade Rear facade
-
NOOSA COUNCIL
APPROVED PLAN
MCU21/0020.01 & OPW21/0035.01
16 NOV 2022
No. Description Date
I Approval Issue J 18/08/2021 Project number Scale at A3
Project Client Drawing Drawn by
dennishillarchitect 27 Grant Street, Brown Rooster Pty 3D PERSPECTIVES DRH
J
K
Construction Issue A
Construction Issue B
08/10/2021
28/10/2021
049
mobile: 0438 20 55 66 | [email protected] Noosa Heads Ltd
www.dennishillarchitect.com
L
M
Construction Issue C
Construction Issue D
11/03/2022
27/06/2022 CON.02
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 27/06/2022 4:54:37 PM
The text continues on page 16.
Used in these records
Combined Approved Plans MCU21-0020.01 & OPW21-0035.01.pdfRelated documentApplication case desk ↗
About this file
- File size
- 24.0 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.