PEREGIAN BEACH VILLAS
I UNITS 8-9 , 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, OLD,
•^Sheet Index
(^Layout ID Layout Name
               Sheet Index
  A.01.1 COVER PAGE
                                                                                                                                                                                                                           NOOSA COUNCIL
  A.01.2 GROUND FLOOR                                                                                                                                                                                                     APPROVED PLANS
  A.01.3 FIRST FLOOR
  A.01.4 ELEVATIONS
                                                                                                                                                                                                                       IV1CU14/0008 26 JUN 2014
  A.01.5 ELEVATIONS

 NOTES




                                                                   FOR CONSTRUCTION OF CONCRETE SLAB, FLOOR SYSTEMS, FRAMES & TRUSS'S PLEASE REFER TO HINTON STEEL FRAMES DRAWINGS

                                                                                                                                                                                                          III r—Wl.,
                                                                                                                                                                                                                             AREAS
GENERAL NOTES                                                                                                                                                                                                               GROSS FLOOR AREA


                                                                                                                                                                                                        HintoN
CONTRACTOR TO CONFIRM ALL DIMENSIONS, LEVELS AND GENERAL PROTECTION FROM TERMITES IS TO BE INSTALLED IN ACCORDANCE ALL BUILDING WORK SHALL COMPLY WITH THE BCA, LOCAL                                                       UNIT 8: 55m2
SITE CONDITIONS INCLUDING LOCATION OF EXISTING SERVICES ON WITH AS3660,1-2000, AND PART 3.1.3 OF THE BCA. AUTHORITY REGULATIONS 8 ALL RELEVANT AUSTRALIAN
SITE PRIOR TO THE COMMENCEMENT OF ANY WORKS STANDARDS
                                                          STAIRS, HANDRAILS AND BALUSTRADES TO BE IN ACCORDANCE
                                                                                                                                                                                          Remote                            UNIT 9: 55 m2
DRAWINGS TO BE READ IN ASSOCIATION WITH SPECIFICATION AND WITH THE B.C.A REFER LANDSCAPE ARCHITECT PLANS FOR LANDSCAPE WORKS
SCHEDULES OF FINISHES
                                                          ALUMINIUM WINDOWS TO BE IN ACCORDANCE WITH AS2047 AND SMOKE ALARMS ARE TO BE HARDWIRED AND IN ACCORDANCE WITH
DIMENSIONS TAKE PRECEDENCE OVER SCALE AS2048 AND CLEAR GLAZING IN ACCORDANCE WITH AS1288 AND AS37a8 8 PART 3.72 OF THE BCA
                                                                                                                                                                                                        STEEL FRAMES
                                                          AS220B AND THE DESIGN CONDITIONS AS NOMINATED
DO NOT SCALE FROM DRAWINGS. REFER ANY DISCREPANCIES CONCEAL ALL VENT PIPES AND WASTE PIPES WITHIN WALL FRAMING
DIRECTLY TO THE SUPERINTENDENT BUILDER IS RESPONSIBLE FOR WATERTIGHTNESS OF THE BUILDING                                                                                                                                     HINTON STEEL FRAMES
                                                          AND MUST PROVIDE FLASHING, SARKING REQUIRED TO PREVENT MAX BUILDING HT ABOVE NATURAL GROUND LINE IS TO BE 8500 mm
REFER TO STRUCTURAL ENGINEERS DRAWINGS FOR ALL FOOTINGS, THE ENTRY OF MOISTURE INTO THE BUILDING. AND IN ACCORDANCE WITH BBC DEVELOPMENT APPROVAL
SLAB AND WALL DETAILS AND SIZING OF STRUCTURAL MEMBERS. REQUIREMENTS
                                                                                                                                                                                 Collins Develooments                        16 Computer Road Yatola
                                                                                                                                                                                                                             Gold Coast
                                                                                                                                                                                                                             qld auslralla 4207
                                                          WATERPROOFING TO WET AREAS IN ACCORDANCE WITH SECTION                                                                                                              lolophono
REFER TO SPECIFICATION FOR RELEVANT AUSTRALIAN STANDARDS. 381 OF THE B.C.A AND AS 3740 SET DOWN FLOOR JOISTS TO ALL UPPER LEVEL BATHROOMS / WET                                                                              (6I7| 3287 3398
                                                                                                                      AREAS FOR FLUSH FLOOR FINISH BETWEEN POLISHED TIMBER                                                   (417)3382 7454
                                                                                                                       FLOORS AND TILED FLOORS - REFER STRUCTURAL ENG DRAWINGS                                               otnall: markU'hlntomtooKramoi.com.au
                                                                                                                       FOR MEMBER SIZES
Log in to download the original file

Attachment 2 - Sealed Final Judgment.pdf · 19.6 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.