20210041 Bottlebrush Ave RECOR RFI Response

of 3

Page text shows just the words. Original shows the document exactly as it was published.

            25th February 2022

            Ref:    MCU21/0214 & OPW21/0356

            Noosa Council
            PO Box 141
            TEWANTIN QLD 4565


            Attention:                        Lisa Pienaar

            Dear Sir,

                        Re:                   Information Request
                        At:                   27 Bottlebrush Ave, Noosa Heads, QLD 4567


            With reference to the abovementioned information request for the development
            application (ref: MCU21/0214 & OPW21/0356), we have prepared an update to the
            engineering aspects of the submission to address the issues raised in the Request for
            Information as follows:

            15. Provide a more detailed longitudinal section of the access driveway. The plan
            must be prepared by an RPEQ and extend from the centreline of the road formation to
            the garage floor level. The plan must include but not be limited to:
                   a. Levels and grades;
                   b. The vehicle clearance for a B99 vehicle as described in AS/NZS2890.1:2004;
                   c. Sufficient detail to demonstrate that vehicles will not bottom out or scrape
                   on the road formation or driveway when entering and exiting the site.

            The grades of the longitudinal section have been updated and vertical clearance
            envelopes for a B99 vehicle as described in AS/NZS2890.1:2004 have been generated
            using AutoTurn software for both access and egress movements of the driveway to
            demonstrate that vehicles will not bottom out or scrape on the proposed alignment. The
            vertical alignment profile is now provided on plan C40 – Swept Path Analysis.


            16. Provide amended plans that indicate the existing services in the frontage adjacent
            to the driveway and the vegetation in the road reserve in front of the adjacent property
            that may be impacted by the proposed works.

            17. Provide detail on how the impacted existing services and vegetation will be
            protected during the construction of the driveway.

            The plans have been amended based on the revised vertical alignment and adjusted
            batter slopes in proximity to the services to achieve a minimum clearance of 200mm from
            the services identified in the survey. This area if proposed to be protected by erecting an
            orange and yellow bunting mesh barrier fence to ensure a works exclusion zone is evident
            to protect these services. The earthworks are also approximately 1.5m clear of existing
            vegetation within the road reserve so works are not expected to impact the existing trees.




P +61 7 5211 1003         A 37 Mary St, Noosaville Qld 4566     E [email protected]   recorconsulting.com
Log in to download the original file

20210041 Bottlebrush Ave RECOR RFI Response.pdf · 156 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

Full text of the other 2 pages

Page 2

            Additional details have been provided demonstrating the zone of stability for the
            telecommunications pole which will not be disturbed, and notes indicating no powered
            excavation near the services have been added to the plan to ensure they are protected
            during construction.

            18. Provide amended plans for the vehicle paths (B99 vehicle as described in
            AS/NZS2890.1:2004) that:
                   a. Indicate that vehicle paths (including overhangs) do not conflict with the
                   proposed basement walls (specifically spaces 1, 3, 5, 6 and 7);
                   b. Indicate separate plans for the entry and exit paths for vehicles accessing
                   spaces 5 and 7;
                   c. Indicate the width of car space 6 noting that the space is bounded on one
                   side by a wall and requires widening in accordance with AS/NZS2890.1:2004.


            The vehicle swept paths for the parking areas have been updated to ensure that the B99
            vehicle paths to not conflict with proposed basement walls nor the adjacent spaces in
            response to the above raised points. It is noted that a 300mm clearance envelope is
            shown around the vehicle body in accordance with AS/NZS2890.1:2004, which may
            overlap adjacent spaces, however this does not represent a conflict of the shown path.

            The spaces have been reconfigured to relocate the visitor space external to the parking
            garage to ensure visitors are able to park without requiring access to operate the vehicle
            turntable. Space 6 has been relocated as a result to ensure it has suitable widths in
            accordance with AS/NZS2890.1:2004. A separate entry and exit movement path has been
            provided for spaces 5 and 7.


            19. Provide additional detail on how visitors to the site will be able to operate the
            vehicle turntable if the particular resident they are visiting is not available.

            The internal parking area has been reconfigured with the visitor space relocated in front
            of the building to allow access and parking without requiring use of the turntable access.


            20. Provide comment from the design engineer regarding the potential for damage to
            the pits and if necessary and provide amended plans accordingly.

            The stormwater drainage line has been designed in accordance with the
            recommendations defined by the Queensland Urban Drainage Manual (QUDM),
            specifically in relation to the acceptable pipe grade limits and flow velocities.

            Section 7.11 of QUDM provides flow velocity limits to ensure scouring and erosion does
            not occur under full and partially full conditions where a desirable maximum velocity of
            4.0m/s under full flow conditions and 4.7m/s under partial flow are acceptable. The
            maximum flow velocity of the proposed stormwater line is 3.6m/s under the peak 1%
            storm event, therefore the flow velocities are below levels that would damage pit and
            pipe infrastructure.




P +61 7 5211 1003       A 37 Mary St, Noosaville Qld 4566    E [email protected]         recorconsulting.com

Page 3

            Similarly, Section 7.12 of QUDM provides maximum pipe and HGL grade limits for full
            flowing pipes. A 300mm diameter pipe (the smallest diameter listed) has a maximum
            grade of 20% to ensure flow is controlled to suitable limits. The maximum pipe grade
            within the proposed design is 15.8%, while the maximum HGL grade line is 16.5% for the
            1% AEP storm event. These are both below the recommended maximum grade, therefore
            the design is considered to be appropriate for the site and within acceptable ranges to
            limit damage to stormwater infrastructure.

            Additionally, concrete bulk heads and trench stops have been added to the drainage
            lines to protect the stormwater trenches from scour resulting in potential pipe movement.

            We believe the revised design addresses the requirements of the RFI and should further
            information be required please contact this office.

            Yours faithfully,
            RECOR Pty Ltd


            Prepared by                                        Reviewed by




            Ben Parry                                          Nathan Wagstaff
            Civil Engineer                                     Manager
            BEng (Hons), MIEAust                               BEng (Hons) MIEAust CPEng NER (Civil, Structural) RPEQ




P +61 7 5211 1003          A 37 Mary St, Noosaville Qld 4566   E [email protected]                 recorconsulting.com

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.