Original source · versioned page text
20210041 Bottlebrush Ave RECOR RFI Response
Similarly, Section 7.12 of QUDM provides maximum pipe and HGL grade limits for full
flowing pipes. A 300mm diameter pipe (the smallest diameter listed) has a maximum
grade of 20% to ensure flow is controlled to suitable limits. The maximum pipe grade
within the proposed design is 15.8%, while the maximum HGL grade line is 16.5% for the
1% AEP storm event. These are both below the recommended maximum grade, therefore
the design is considered to be appropriate for the site and within acceptable ranges to
limit damage to stormwater infrastructure.
Additionally, concrete bulk heads and trench stops have been added to the drainage
lines to protect the stormwater trenches from scour resulting in potential pipe movement.
We believe the revised design addresses the requirements of the RFI and should further
information be required please contact this office.
Yours faithfully,
RECOR Pty Ltd
Prepared by Reviewed by
Ben Parry Nathan Wagstaff
Civil Engineer Manager
BEng (Hons), MIEAust BEng (Hons) MIEAust CPEng NER (Civil, Structural) RPEQ
P +61 7 5211 1003 A 37 Mary St, Noosaville Qld 4566 E [email protected] recorconsulting.com