Attachment 1C - UNITS 04 & 05
Attached to the e-mail Development Application MCU - 226 David Low Way Peregian Beach Units 4-5 (Email 5).
PEREGIAN BEACH VILLAS UNIT 4 & 5, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, Sheet Index Layout ID Layout Name Published Sheet Index A.01.1 COVER PAGE A.01.2 GROUND FLOOR A.01.3 FIRST FLOOR A.01.4 ELEVATIONS A.01.5 ELEVATIONS NOTES FOR CONSTRUCTION OF CONCRETE SLAB, FLOOR SYSTEMS, FRAMES & TRUSS'S PLEASE REFER TO HINTON STEEL FRAMES DRAWINGS AREAS GENERAL NOTES GROSS FLOOR AREA CONTRACTOR TO CONFIRM ALL DIMENSIONS, LEVELS AND GENERAL PROTECTION FROM TERMITES IS TO BE INSTALLED IN ACCORDANCE ALL BUILDING WORK SHALL COMPLY WITH THE BCA, LOCAL UNIT 4: 85m2 SITE CONDITIONS INCLUDING LOCATION OF EXISTING SERVICES ON WITH AS3660.1-2000. AND PART 3.1.3 OF THE BCA. AUTHORITY REGULATIONS & ALL RELEVANT AUSTRALIAN SITE PRIOR TO THE COMMENCEMENT OF ANY WORKS. STANDARDS. UNIT 5: 50 m2 STAIRS, HANDRAILS AND BALUSTRADES TO BE IN ACCORDANCE DRAWINGS TO BE READ IN ASSOCIATION WITH SPECIFICATION AND WITH THE B.C.A. REFER LANDSCAPE ARCHITECT PLANS FOR LANDSCAPE WORKS SCHEDULES OF FINISHES. ALUMINIUM WINDOWS TO BE IN ACCORDANCE WITH AS2047 AND SMOKE ALARMS ARE TO BE HARDWIRED AND IN ACCORDANCE WITH DIMENSIONS TAKE PRECEDENCE OVER SCALE. AS2048 AND CLEAR GLAZING IN ACCORDANCE WITH AS1288 AND AS3788 & PART 3.72 OF THE BCA AS2208 AND THE DESIGN CONDITIONS AS NOMINATED. DO NOT SCALE FROM DRAWINGS. REFER ANY DISCREPANCIES CONCEAL ALL VENT PIPES AND WASTE PIPES WITHIN WALL FRAMING Collins Developments DIRECTLY TO THE SUPERINTENDENT. BUILDER IS RESPONSIBLE FOR WATERTIGHTNESS OF THE BUILDING HINTON STEEL FRAMES AND MUST PROVIDE FLASHING, SARKING REQUIRED TO PREVENT MAX BUILDING HT ABOVE NATURAL GROUND LINE IS TO BE 8500 mm 16 Computer Road Yatala REFER TO STRUCTURAL ENGINEERS DRAWINGS FOR ALL FOOTINGS, THE ENTRY OF MOISTURE INTO THE BUILDING. AND IN ACCORDANCE WITH BBC DEVELOPMENT APPROVAL Gold Coast SLAB AND WALL DETAILS AND SIZING OF STRUCTURAL MEMBERS. REQUIREMENTS qld australia 4207 WATERPROOFING TO WET AREAS IN ACCORDANCE WITH SECTION telephone REFER TO SPECIFICATION FOR RELEVANT AUSTRALIAN STANDARDS. 3.8.1 OF THE B.C.A AND AS 3740 SET DOWN FLOOR JOISTS TO ALL UPPER LEVEL BATHROOMS / WET (617) 3287 3398 facsimilie AREAS FOR FLUSH FLOOR FINISH BETWEEN POLISHED TIMBER (617) 3382 7656 FLOORS AND TILED FLOORS - REFER STRUCTURAL ENG DRAWINGS email: [email protected] FOR MEMBER SIZES w w w .h i n t o n s t e e l f r a m e s .c o m .a u
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 4 pages
Page 2
GENERAL NOTES
PEREGIAN BEACH VILLAS UNIT 4 & 5, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD,
CONTRACTOR TO CONFIRM ALL DIMENSIONS, LEVELS AND GENERAL
SITE CONDITIONS INCLUDING LOCATION OF EXISTING SERVICES ON
SITE PRIOR TO THE COMMENCEMENT OF ANY WORKS.
DRAWINGS TO BE READ IN ASSOCIATION WITH SPECIFICATION AND
SCHEDULES OF FINISHES.
DIMENSIONS TAKE PRECEDENCE OVER SCALE.
DO NOT SCALE FROM DRAWINGS. REFER ANY DISCREPANCIES
DIRECTLY TO THE SUPERINTENDENT.
REFER TO STRUCTURAL ENGINEERS DRAWINGS FOR ALL FOOTINGS,
SLAB AND WALL DETAILS AND SIZING OF STRUCTURAL MEMBERS.
1,310 1,127 1,563 90 3,045 250 4,525
REFER TO SPECIFICATION FOR RELEVANT AUSTRALIAN STANDARDS.
90 1,220 90 1,690 90 3,990 180 4,470 90 PROTECTION FROM TERMITES IS TO BE INSTALLED IN ACCORDANCE
WITH AS3660.1-2000. AND PART 3.1.3 OF THE BCA.
90 1,690 90 900 1,410 90 1,590 180 690 90 2,220 90 1,380 90 STAIRS, HANDRAILS AND BALUSTRADES TO BE IN ACCORDANCE
WITH THE B.C.A.
ALUMINIUM WINDOWS TO BE IN ACCORDANCE WITH AS2047 AND
AS2048 AND CLEAR GLAZING IN ACCORDANCE WITH AS1288 AND
Patio AS2208 AND THE DESIGN CONDITIONS AS NOMINATED.
1 x 3.5
740
BUILDER IS RESPONSIBLE FOR WATERTIGHTNESS OF THE BUILDING
AND MUST PROVIDE FLASHING, SARKING REQUIRED TO PREVENT
THE ENTRY OF MOISTURE INTO THE BUILDING.
90
Patio
2,440
2,440
1,095
1,095
2.5X4.5 WATERPROOFING TO WET AREAS IN ACCORDANCE WITH SECTION
3.8.1 OF THE B.C.A AND AS 3740
90
Bedroom ALL BUILDING WORK SHALL COMPLY WITH THE BCA, LOCAL
AUTHORITY REGULATIONS & ALL RELEVANT AUSTRALIAN
3.1 x 3.8
3,820
1,890
STANDARDS.
90
90
1,800
WIR
REFER LANDSCAPE ARCHITECT PLANS FOR LANDSCAPE WORKS
SMOKE ALARMS ARE TO BE HARDWIRED AND IN ACCORDANCE WITH
AS3788 & PART 3.72 OF THE BCA
90 Multi purpose room
3,470
3,470
3.5 x 4.5 CONCEAL ALL VENT PIPES AND WASTE PIPES WITHIN WALL FRAMING
90
SHR
380
LINEN MAX BUILDING HT ABOVE NATURAL GROUND LINE IS TO BE 8500 mm
T W
AND IN ACCORDANCE WITH BBC DEVELOPMENT APPROVAL
90
REQUIREMENTS
3,710
3,620
16
Ens 15
90
SET DOWN FLOOR JOISTS TO ALL UPPER LEVEL BATHROOMS / WET
1.7 x 3.6 14
AREAS FOR FLUSH FLOOR FINISH BETWEEN POLISHED TIMBER
380
90
LINEN T 13
FLOORS AND TILED FLOORS - REFER STRUCTURAL ENG DRAWINGS
W
12 FOR MEMBER SIZES
90
WC
11
UNIT 4 UNIT 5 10
9
LEGEND
A/C AIR CONDITIONING AS SPEC. - INSTALLED
90
8
BY CONTRACTOR
Single Garage 7 Bistro style blinds to AP 450 X450 REMOVABLE ACCESS
external staircase
6,000
6.0 x 3.0 6
PANEL - LOCATION TO BE CONFIRMED ON SITE
10
12
13
14
15
16
17
11
9
BL CONC. BLOCK WALL TO STRUCTURAL ENG.
2,380
5
2,200
4 Staircase open to DETAIL - RENDER AND PAINT AS SPEC.
8
7
6
5
4
3
2
1
D-02 3
external units CF COLORBOND FLASHING TO DETAIL
5,950
CJ CLADDING CONTROL JOINT - REFER ELEVATIONS
Single Garage 2
1 CONC CONCRETE SLAB TO ENG. DETAIL
6.1 x 3.0
6,090
CPD CUPBOARD
DP 90mm DIA DOWNPIPE AS SPEC.
90
D-02 REFER TO DETAILS FOR TYPICAL FIXING
Entry DRY CLOTHES DRYER
1,735
Entry
1,645
1.6 x 2.1 DW DISHWASHER
2.6 x 1.4 EG COLORBOND EAVES GUTTER TO PROFILE SHOWN WITH
GUTTER BRACKETS @ MAX 900 CRS
EGL EXISTING GROUNDLINE
90
F REFRIGERATOR
90
Patio FW FLOOR WASTE
1,250
1,750
GD S.S GRATED DRAIN AS SPEC.
1.5 x 5.3
1,500
90
HC HOSE COCK - REFER FLOOR PLANS FOR LOCATION
HP HOT PLATES AS SPEC.
HWU HOT WATER
90
610
MR MECHANICAL RISER
270
MW MICROWAVE
NGL NATURAL GROUND LINE
90 510 90 2,080 90 3,000 180 3,000 90 1,470 90 OV OVEN
P PANTRY
PGL PROPOSED GROUNDLINE
1,310 600 5,350 3,180 1,560 PTF POLISHED TIMBER FLOOR AS SPEC.
RHS RHS TO STRUCTURAL. ENG. DETAIL
RV "WIRILY BIRD" OR SIM. APPROVED
S SINK
SD HARDWIRED SMOKE DETECTOR TO
COMPLY WITH A.S. 3786-1993
SHR SHOWER TO DETAIL
SHS SHS TO STRUCTURAL. ENG. DETAIL
SL SKYLIGHT AS SPEC.
T TUB
T-1 INTERNAL TILE AS SPEC.
T-2 EXTERNAL TILE AS SPEC.
TD HWD TIMBER DECKING AS SPEC.
TOW TOP OF WALL
VAC IN-BUILT VACUUM SYSTEM AS SPEC.
VB VANITY BASIN
WC TOILET SUITE
WF COLORBOND WALL FLASHING
WM WASHING MACHINE
Amendments Wind Rating Checked By: Status: PR Date: 21.01.14
PEREGIAN BEACH VILLAS
A 06.12.13 Preliminary Client Approval TB Scale: 1:100 @ A3 Drawn by: CT
Client Signiture Approval:
B 00.12.13 Amends TB Client Initials:
TBC
ALEX CHARLWOOD Drawing Title:
C 11.12.13 Site plan revised + amendments CT Date:
UNIT 4 & 5, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, D 16.01.14 Amend GFA CT
PH: 0410 650 745
GROUND FLOOR
BSB No.: 1043429
E 21.01.14 Client request amendments CT NOTES: Client: Drawing No.:
ABN: 59 980 573 352
PR Drawings by HINTON STEEL FRAME QLD PTY LTD. ECO REMOTE A.01.2 E
ALL PLANS ARE COPYRIGHT AND MAY NOT BE REPRODUCED IN WHOLE OR AND PART WITHOUT WRITTEN PERMISION FROM HINTON STEEL FRAMES
Page 3
GENERAL NOTES
PEREGIAN BEACH VILLAS UNIT 4 & 5, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD,
CONTRACTOR TO CONFIRM ALL DIMENSIONS, LEVELS AND GENERAL
SITE CONDITIONS INCLUDING LOCATION OF EXISTING SERVICES ON
SITE PRIOR TO THE COMMENCEMENT OF ANY WORKS.
DRAWINGS TO BE READ IN ASSOCIATION WITH SPECIFICATION AND
SCHEDULES OF FINISHES.
DIMENSIONS TAKE PRECEDENCE OVER SCALE.
DO NOT SCALE FROM DRAWINGS. REFER ANY DISCREPANCIES
DIRECTLY TO THE SUPERINTENDENT.
REFER TO STRUCTURAL ENGINEERS DRAWINGS FOR ALL FOOTINGS,
410 SLAB AND WALL DETAILS AND SIZING OF STRUCTURAL MEMBERS.
1,310 1,969 90 3,766 250 4,435 90 90
REFER TO SPECIFICATION FOR RELEVANT AUSTRALIAN STANDARDS.
90 410
90 1,220 90 5,735 250 3,465 90 880 90 PROTECTION FROM TERMITES IS TO BE INSTALLED IN ACCORDANCE
WITH AS3660.1-2000. AND PART 3.1.3 OF THE BCA.
STAIRS, HANDRAILS AND BALUSTRADES TO BE IN ACCORDANCE
WITH THE B.C.A.
60
1,005
ALUMINIUM WINDOWS TO BE IN ACCORDANCE WITH AS2047 AND
90
1,000
940
AS2048 AND CLEAR GLAZING IN ACCORDANCE WITH AS1288 AND
AS2208 AND THE DESIGN CONDITIONS AS NOMINATED.
90
60
BUILDER IS RESPONSIBLE FOR WATERTIGHTNESS OF THE BUILDING
90
AND MUST PROVIDE FLASHING, SARKING REQUIRED TO PREVENT
3,959
3,240
THE ENTRY OF MOISTURE INTO THE BUILDING.
Outdoor balcony Outdoor balcony
2,954
3.0 x 4.7
2,909
2.2 x 4.5 WATERPROOFING TO WET AREAS IN ACCORDANCE WITH SECTION
3.8.1 OF THE B.C.A AND AS 3740
ALL BUILDING WORK SHALL COMPLY WITH THE BCA, LOCAL
3,830
4,010
AUTHORITY REGULATIONS & ALL RELEVANT AUSTRALIAN
STANDARDS.
90
90
90
REFER LANDSCAPE ARCHITECT PLANS FOR LANDSCAPE WORKS
SMOKE ALARMS ARE TO BE HARDWIRED AND IN ACCORDANCE WITH
AS3788 & PART 3.72 OF THE BCA
Kitchen / Living
90
4.2 x 3.5 CONCEAL ALL VENT PIPES AND WASTE PIPES WITHIN WALL FRAMING
Living Dining
4,180
3,710
3,620
16
3.7 x 3.5 3.3 x 2.3 15 MAX BUILDING HT ABOVE NATURAL GROUND LINE IS TO BE 8500 mm
14 AND IN ACCORDANCE WITH BBC DEVELOPMENT APPROVAL
Deck 13
REQUIREMENTS
UNIT 4 UNIT 5 12
SET DOWN FLOOR JOISTS TO ALL UPPER LEVEL BATHROOMS / WET
5,910
3,690
11
AREAS FOR FLUSH FLOOR FINISH BETWEEN POLISHED TIMBER
10
FLOORS AND TILED FLOORS - REFER STRUCTURAL ENG DRAWINGS
9
FOR MEMBER SIZES
90
90
8
LEGEND
500
7
6
6,640
Kitchen A/C AIR CONDITIONING AS SPEC. - INSTALLED
10
12
13
14
15
16
17
11
9
2,380
5
90
D-21 BY CONTRACTOR
2,200
8
2.6 x 3.1 4
AP 450 X450 REMOVABLE ACCESS
7
6
5
4
3
2
1
90
3
PANEL - LOCATION TO BE CONFIRMED ON SITE
2
SH BL CONC. BLOCK WALL TO STRUCTURAL ENG.
1
DETAIL - RENDER AND PAINT AS SPEC.
Bed CF COLORBOND FLASHING TO DETAIL
3,280
90
90
3.3 x 3.0 CJ CLADDING CONTROL JOINT - REFER ELEVATIONS
2,770
Ens CONC CONCRETE SLAB TO ENG. DETAIL
CPD CUPBOARD
Study DP 90mm DIA DOWNPIPE AS SPEC.
2,345
2,255
2,255
WC 2.3 x 4.1 WC
REFER TO DETAILS FOR TYPICAL FIXING
DRY CLOTHES DRYER
WC
90
DW DISHWASHER
WC
EG COLORBOND EAVES GUTTER TO PROFILE SHOWN WITH
90
Deck GUTTER BRACKETS @ MAX 900 CRS
1,000
1,090
EGL EXISTING GROUNDLINE
90
90
Deck 0.9 x 3.6 0.9 x 4.5 F REFRIGERATOR
910
FW FLOOR WASTE
1,000
90
GD S.S GRATED DRAIN AS SPEC.
900
900
HC HOSE COCK - REFER FLOOR PLANS FOR LOCATION
90
HP HOT PLATES AS SPEC.
HWU HOT WATER
MR MECHANICAL RISER
90 90 MW MICROWAVE
90 1,820 90 1,000 90 4,045 250 2,015 90 810 460 880 90
NGL NATURAL GROUND LINE
OV OVEN
P PANTRY
1,910 90 1,470 3,665 250 2,915 90 1,430 90 PGL PROPOSED GROUNDLINE
PTF POLISHED TIMBER FLOOR AS SPEC.
RHS RHS TO STRUCTURAL. ENG. DETAIL
1,910 5,225 250 4,525 RV "WIRILY BIRD" OR SIM. APPROVED
S SINK
SD HARDWIRED SMOKE DETECTOR TO
COMPLY WITH A.S. 3786-1993
SHR SHOWER TO DETAIL
SHS SHS TO STRUCTURAL. ENG. DETAIL
SL SKYLIGHT AS SPEC.
T TUB
T-1 INTERNAL TILE AS SPEC.
T-2 EXTERNAL TILE AS SPEC.
TD HWD TIMBER DECKING AS SPEC.
TOW TOP OF WALL
VAC IN-BUILT VACUUM SYSTEM AS SPEC.
VB VANITY BASIN
WC TOILET SUITE
WF COLORBOND WALL FLASHING
WM WASHING MACHINE
Amendments Wind Rating Checked By: Status: PR Date: 21.01.14
PEREGIAN BEACH VILLAS
A 06.12.13 Preliminary Client Approval TB Scale: 1:100 @ A3 Drawn by: CT
Client Signiture Approval:
B 00.12.13 Amends TB Client Initials:
TBC
ALEX CHARLWOOD Drawing Title:
C 11.12.13 Site plan revised + amendments CT Date:
UNIT 4 & 5, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, D 16.01.14 Amend GFA CT
PH: 0410 650 745
FIRST FLOOR
BSB No.: 1043429
E 21.01.14 Client request amendments CT NOTES: Client: Drawing No.:
ABN: 59 980 573 352
PR Drawings by HINTON STEEL FRAME QLD PTY LTD. ECO REMOTE A.01.3 E
ALL PLANS ARE COPYRIGHT AND MAY NOT BE REPRODUCED IN WHOLE OR AND PART WITHOUT WRITTEN PERMISION FROM HINTON STEEL FRAMES
Page 4
ELEVATION LEGEND
PEREGIAN BEACH VILLAS UNIT 4 & 5, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, D-0
WD-0
DOOR NUMBER
WINDOW NUMBER
CF CLADDING FINISH
ABBREVIATIONS
AC AIR-CONDITIONING
Rendered fire rated wall in ALY ALYSNITE FLAT SHEETING
accordance with BLK BLOCKWORK
manufacturers specifications CN CONCRETE
Roof sheets @ 70 pitch fixed
DP1 90Ø DOWNPIPE
in accordance with EG1 EAVES GUTTER
manufactures specification FC FIBRE CEMENT WITH 10mm EXPRESSED
Specified cladding fixed in JOINTS
accordance with manufactures FCC COMPRESSED FIBRE CEMENT
specification FL FLASHING
Ceiling Level Ceiling Level LVF FIXED ALUMINIUM LOUVRE
MRS METAL ROOF SHEETING
Exposed rafters to roof system ZINC ZINC CLADDING WITH STANDING SEAM
NGL NATURAL GROUND LINE
PLY PLYWOOD WITH 10mm EXPRESSED
2,740
2,740
JOINTS
SPR SPREADER
Glass Ballustrade in SPT SPITTER
accordance with BCA & Aus Timber screen to juliet style balcony
Standards
Floor Level
Floor Level
Specified cladding fixed in Ceiling Level
Aluminium framed windows
Ceiling Level
fixed to manufactures accordance with manufactures
specifications specification
2,740
2,740
Aluminium screens
Steel beams in accordance
to engineers specifications
21 - 24 roller door
Slab Level NGL NGL Slab Level
1 Front Elevation 1:100
Aluminium framed windows and
Roof sheets @ 70 pitch fixed
sliding doors fixed to manufactures
in accordance with
specifications
manufactures specification
Roof sheets @ 70 pitch fixed
0
Roof sheets @ 7 pitch fixed in accordance with
in accordance with manufactures specification
manufactures specification
Bay window, with specified cladding
Ceiling Level fixed in accordance with Ceiling Level
manufactures specification
Louvered window system, to be installed in
2,740
2,740
accordance with manufacturers
specifications
Timber screen
Floor Level Floor Level
Ceiling Level Specified cladding fixed in Ceiling Level
accordance with manufactures
Steel column to engineers specification
specification
Rendered fire rated wall in
2,740
2,740
Aluminium screen, in
accordance with manufacteres accordance with
specifications manufacturers specifications
Slab Level NGL NGL Slab Level
2 Right 1 Elevation 1:100
Amendments Wind Rating Checked By: Status: PR Date: 21.01.14
PEREGIAN BEACH VILLAS
A 06.12.13 Preliminary Client Approval TB Scale: 1:100 @ A3 Drawn by: CT
Client Signiture Approval:
B 00.12.13 Amends TB Client Initials:
TBC
ALEX CHARLWOOD Drawing Title:
C 11.12.13 Site plan revised + amendments CT Date:
UNIT 4 & 5, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, D 16.01.14 Amend GFA CT
PH: 0410 650 745
ELEVATIONS
BSB No.: 1043429
E 21.01.14 Client request amendments CT NOTES: Client: Drawing No.:
ABN: 59 980 573 352
PR Drawings by HINTON STEEL FRAME QLD PTY LTD. ECO REMOTE A.01.4 E
ALL PLANS ARE COPYRIGHT AND MAY NOT BE REPRODUCED IN WHOLE OR AND PART WITHOUT WRITTEN PERMISION FROM HINTON STEEL FRAMES
Page 5
ELEVATION LEGEND
PEREGIAN BEACH VILLAS UNIT 4 & 5, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, D-0
WD-0
DOOR NUMBER
WINDOW NUMBER
CF CLADDING FINISH
ABBREVIATIONS
Rendered fire rated wall in
accordance with Roof sheets @ 70 pitch fixed AC AIR-CONDITIONING
manufacturers specifications in accordance with ALY ALYSNITE FLAT SHEETING
BLK BLOCKWORK
manufactures specification CN CONCRETE
DP1 90Ø DOWNPIPE
Exposed rafters to roof system
EG1 EAVES GUTTER
FC FIBRE CEMENT WITH 10mm EXPRESSED
JOINTS
Bay window, with specified cladding FCC COMPRESSED FIBRE CEMENT
Ceiling Level fixed in accordance with Steel Column to engineers Ceiling Level FL FLASHING
manufactures specification specification LVF FIXED ALUMINIUM LOUVRE
MRS METAL ROOF SHEETING
Aluminium framed bifold ZINC ZINC CLADDING WITH STANDING SEAM
Aluminium framed bifold windows NGL NATURAL GROUND LINE
beyond fixed to manufactures windows fixed to manufactures
2,740
2,740
PLY PLYWOOD WITH 10mm EXPRESSED
specifications specifications JOINTS
SPR SPREADER
Glass Ballustrade to be installed SPT SPITTER
Timber ballustrade, in
in accordance with BCA and
Floor Level accordance with the BCA and Floor Level
Aus standards
Ceiling Level relevant Aus Standards Ceiling Level
Aluminium framed windows and
Specified cladding, to be
2,740
2,740
sliding doors fixed to manufactures
specifications installed in accordance with
manufacturers specifications
Selected rendered finish
Slab Level Slab Level
NGL NGL
3 Rear Elevation 1:100
Aluminium screen, in
accordance with manufacteres
specifications Roof sheets @ 70 pitch fixed
in accordance with
Roof sheets @ 70 pitch fixed manufactures specification
in accordance with
manufactures specification
Roof sheets @ 70 pitch fixed
in accordance with
Ceiling Level
manufactures specification Ceiling Level
Exposed rafters to roof system
Rendered fire rated parti wall in accordance Fire rated parti wall in
with engineers specifications accordance with engineers
specifications
2,740
2,740
Steel column in accordance with engineers
specifications
Glass Ballustrade to be installed in Timber screen
accordance with BCA and Aus standards
Floor Level Floor Level
Ceiling Level Ceiling Level
Specified cladding fixed in
accordance with manufactures
2,740
2,740
Specified cladding fixed in accordance with specification
manufactures specification
Aluminium framed windows and
sliding doors fixed to manufactures
Slab Level specifications Slab Level
NGL NGL
4 Left Elevation 1:100
Amendments Wind Rating Checked By: Status: PR Date: 21.01.14
PEREGIAN BEACH VILLAS
A 06.12.13 Preliminary Client Approval TB Scale: 1:100 @ A3 Drawn by: CT
Client Signiture Approval:
B 00.12.13 Amends TB Client Initials:
TBC
ALEX CHARLWOOD Drawing Title:
C 11.12.13 Site plan revised + amendments CT Date:
UNIT 4 & 5, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, D 16.01.14 Amend GFA CT
PH: 0410 650 745
ELEVATIONS
BSB No.: 1043429
E 21.01.14 Client request amendments CT NOTES: Client: Drawing No.:
ABN: 59 980 573 352
PR Drawings by HINTON STEEL FRAME QLD PTY LTD. ECO REMOTE A.01.5 E
ALL PLANS ARE COPYRIGHT AND MAY NOT BE REPRODUCED IN WHOLE OR AND PART WITHOUT WRITTEN PERMISION FROM HINTON STEEL FRAMES