Original source · versioned page text
Attachment 1C - UNITS 04 & 05
Attached to the e-mail Development Application MCU - 226 David Low Way Peregian Beach Units 4-5 (Email 5).
ELEVATION LEGEND PEREGIAN BEACH VILLAS UNIT 4 & 5, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, D-0 WD-0 DOOR NUMBER WINDOW NUMBER CF CLADDING FINISH ABBREVIATIONS AC AIR-CONDITIONING Rendered fire rated wall in ALY ALYSNITE FLAT SHEETING accordance with BLK BLOCKWORK manufacturers specifications CN CONCRETE Roof sheets @ 70 pitch fixed DP1 90Ø DOWNPIPE in accordance with EG1 EAVES GUTTER manufactures specification FC FIBRE CEMENT WITH 10mm EXPRESSED Specified cladding fixed in JOINTS accordance with manufactures FCC COMPRESSED FIBRE CEMENT specification FL FLASHING Ceiling Level Ceiling Level LVF FIXED ALUMINIUM LOUVRE MRS METAL ROOF SHEETING Exposed rafters to roof system ZINC ZINC CLADDING WITH STANDING SEAM NGL NATURAL GROUND LINE PLY PLYWOOD WITH 10mm EXPRESSED 2,740 2,740 JOINTS SPR SPREADER Glass Ballustrade in SPT SPITTER accordance with BCA & Aus Timber screen to juliet style balcony Standards Floor Level Floor Level Specified cladding fixed in Ceiling Level Aluminium framed windows Ceiling Level fixed to manufactures accordance with manufactures specifications specification 2,740 2,740 Aluminium screens Steel beams in accordance to engineers specifications 21 - 24 roller door Slab Level NGL NGL Slab Level 1 Front Elevation 1:100 Aluminium framed windows and Roof sheets @ 70 pitch fixed sliding doors fixed to manufactures in accordance with specifications manufactures specification Roof sheets @ 70 pitch fixed 0 Roof sheets @ 7 pitch fixed in accordance with in accordance with manufactures specification manufactures specification Bay window, with specified cladding Ceiling Level fixed in accordance with Ceiling Level manufactures specification Louvered window system, to be installed in 2,740 2,740 accordance with manufacturers specifications Timber screen Floor Level Floor Level Ceiling Level Specified cladding fixed in Ceiling Level accordance with manufactures Steel column to engineers specification specification Rendered fire rated wall in 2,740 2,740 Aluminium screen, in accordance with manufacteres accordance with specifications manufacturers specifications Slab Level NGL NGL Slab Level 2 Right 1 Elevation 1:100 Amendments Wind Rating Checked By: Status: PR Date: 21.01.14 PEREGIAN BEACH VILLAS A 06.12.13 Preliminary Client Approval TB Scale: 1:100 @ A3 Drawn by: CT Client Signiture Approval: B 00.12.13 Amends TB Client Initials: TBC ALEX CHARLWOOD Drawing Title: C 11.12.13 Site plan revised + amendments CT Date: UNIT 4 & 5, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, D 16.01.14 Amend GFA CT PH: 0410 650 745 ELEVATIONS BSB No.: 1043429 E 21.01.14 Client request amendments CT NOTES: Client: Drawing No.: ABN: 59 980 573 352 PR Drawings by HINTON STEEL FRAME QLD PTY LTD. ECO REMOTE A.01.4 E ALL PLANS ARE COPYRIGHT AND MAY NOT BE REPRODUCED IN WHOLE OR AND PART WITHOUT WRITTEN PERMISION FROM HINTON STEEL FRAMES
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.