Council archive · source document
SUPERSEDED Decision Notice - Change to an Existing Approval - 010.2005.00001189.003 [As Published] · 132005.1189.03
2005/1189
53. Sewer relocation works shall be in accordance with Construction Hydraulics Drawings 1470-S-
1 and 1470-O-2 and Noosa Shire Council Planning Scheme Policy 6, Engineering Design
Standards, Water & Sewerage.
54. Sewer relocation works are to be completed prior to the commencement of any buildings
works on the site.
55. The existing sewer main that shall be relocated along the side boundary and the outer limits of
the proposed conduit shall be accurately located and determined by a licensed Surveyor and
shown on all plans submitted for Operational Works approval.
To ensure Council’s sewer main is accessible for maintenance purposes and is protected from
risk of damage no structures requiring a building permit (eg. buildings, retaining walls, etc)
shall be constructed within this ‘zone of influence’ ie. the edges of the conduit, and as such the
applicant shall amend Operational Works plans including Building plans to ensure compliance.
Town Water Supply
56. The site shall be connected to Council’s existing town water supply and be constructed in
accordance with Council’s standards and requirements at no cost to Council.
57. Each water connection to the water reticulation system shall extend to the property boundary
and be metered. Where multiple units including leased buildings are served by a single
service, multiple water meters to each individual unit or leased building shall be installed. All
fees for the supply of water meters shall be paid to the Council.
Service Easements (Sewer)
58. A registered easement shall be created over the zone of influence, that is the limits of the
proposed conduit chamber of the relocated sewer within the subject site and over those parts
of the subject site that are impacted upon by sewers on any adjoining sites. In this regard a
licensed surveyor shall accurately locate all sewer mains and determine the necessary width
of the easement, which shall be shown on any plans submitted for Operational Works /
Building Works approval. To this extent the surveyor shall certify that the sewer and the zone
of influence is wholly contained within the easement to be created.
In addition to this the Applicant’s Solicitor shall give Council’s Solicitor an appropriate
undertaking in writing that the Title Deed and the easement documents will be lodged at the
Land Titles Office and any additional Titles Office forms or requisitions requiring the consent of
Council will be attended to promptly.
A duly executed copy of the easement shall be submitted to Council for perusal prior to the
use commencing.
Any changes required by Council’s Solicitor must be corrected immediately.
59. A registered easement shall be created over any stormwater drainage pipes within the site
that collect stormwater from a Council road or convey stormwater from any adjoining property
(for example, where drainage pipes are provided within the site to prevent adjacent properties
from additional ponding/flooding due to the subject site being filled).
60. No building or other structure shall be constructed or encroach over an easement. Any
building or structure within proximity of an easement or any other public utility’s underground
must have its foundations designed so that no surcharge loads are imposed upon such
underground infrastructure. Foundations must be taken down a minimum of 1.0m below a line
of influence measured 1.0m in the direction of the foundation from the centreline of the closest
underground service and along the natural angle of repose of the foundation soil type(s).
Plans, and supportive documents, detailing these proposed foundations shall be designed by
a registered practicing Geotechnical Engineer and submitted with the application for a
Development Permit for Operational Works.
Page 8 of 17
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
SUPERSEDED Decision Notice - Change to an Existing Approval - 010.2005.00001189.003 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 91 KB (small file)
- File type
No other editions are linked here.